  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 197ft / 59.8mTotal length
  • $10,945,000Total costs
  • 365,934Total average daily traffic
  • 35,539Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wilmington Manor
  • No street view available for this location

New bridges in Wilmington Manor, DE - historical statistics
  • New bridges - historical statistics
  • 91950-1959
  • 22000-2009
Average Bridge Daily Traffic in Wilmington Manor, DE
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 60.0%Good
  • 40.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 60.0%Good
  • 40.0%Satisfactory
Find on map >>   Show street view

Structure Number: 1666 033,  Location: FARNHURST (Lat: 39.698389,  Lng: -75.572917),  Route carried "on" structure: US 33,  Year Built: 2003,  Status: Open,  Structure Length: 1.72m (5.64ft),  Average Daily Traffic: 17,648 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 21,935 (year 2042),  Design Load: HS 25 or greater,  Features Intersected: I295 SOUTH TO US13 SOUTH,  Facility Carried by Structure: DUPONT HWY/US13NB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.729,  Lanes on structure: 4,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: Local Toll Authority,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.2m (56.4ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 88.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1680 006,  Location: BASIN CORNER (Lat: 39.680486,  Lng: -75.590372),  Route carried "on" structure: State highway 141,  Year Built: 1955,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 18.35m (60.20ft),  Average Daily Traffic: 21,517 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 26,744 (year 2042),  Design Load: HS 20,  Features Intersected: US 13
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.710,  Lanes on structure: 4,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 30.3m (99.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 18.35m (60.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $3,672,000,  Roadway Improvement Cost: $367,000,  Total Project Cost: $5,508,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1727 056,  Location: FARNHURST (Lat: 39.695253,  Lng: -75.576839),  Route carried "on" structure: Interstate 295,  Year Built: 1958,  Status: Open,  Structure Length: 12.83m (42.09ft),  Average Daily Traffic: 61,768 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 76,773 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: US 13 NB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.890,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: Local Toll Authority,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 27.6m (90.6ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1728 6116,  Location: FARNHURST (Lat: 39.695467,  Lng: -75.576964),  Route carried "on" structure: Ramp Interstate 295,  Year Built: 1958,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 3,284 (year 2016),  Truck Traffic: 11%,  Average Future Daily Traffic: 4,239 (year 2043),  Design Load: HS 20,  Features Intersected: US13, RD33 SB.
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.209,  Lanes on structure: 1,  Lanes under structure: 3,  Owner: Local Toll Authority,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.7m (81.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1729 056,  Location: FARNHURST (Lat: 39.695964,  Lng: -75.575911),  Route carried "on" structure: Interstate 295,  Year Built: 1958,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 21.91m (71.88ft),  Average Daily Traffic: 61,296 (year 2018),  Truck Traffic: 15%,  Average Future Daily Traffic: 77,640 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: US13 & I295S-US13SB RAMP
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 32.140,  Lanes on structure: 3,  Lanes under structure: 9,  Base Highway Network: Yes,  Owner: Local Toll Authority,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 16 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 38.6m (126.6ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 22.10m (72.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $3,625,000,  Roadway Improvement Cost: $362,000,  Total Project Cost: $5,437,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1666 033,  Location: FARNHURST (Lat: 39.698389,  Lng: -75.572917),  Route carried "under" structure: Ramp Interstate 295,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 10,361 (year 2013),  Truck Traffic: 12%,  Features Intersected: I295 SOUTH TO US13 SOUTH,  Facility Carried by Structure: DUPONT HWY/US13NB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 6.200,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.2m (56.4ft)

Find on map >>   Show street view

Structure Number: 1680 006,  Location: BASIN CORNER (Lat: 39.680486,  Lng: -75.590372),  Route carried "under" structure: US 13,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 57,433 (year 2019),  Truck Traffic: 9%,  Features Intersected: US 13,  Facility Carried by Structure: BASIN RD/SR141
Minimum Vertical Clearance: 4.73m (15.52ft),  Kilometerpoint: 3.670,  Lanes on structure: 4,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.3m (99.4ft)

Find on map >>   Show street view

Structure Number: 1727 056,  Location: FARNHURST (Lat: 39.695253,  Lng: -75.576839),  Route carried "under" structure: US 13,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 35,296 (year 2019),  Truck Traffic: 9%,  Features Intersected: US 13 NB,  Facility Carried by Structure: I 295 NB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 5.730,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.6m (90.6ft)

Find on map >>   Show street view

Structure Number: 1728 6116,  Location: FARNHURST (Lat: 39.695467,  Lng: -75.576964),  Route carried "under" structure: US 13,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 28,474 (year 2016),  Truck Traffic: 9%,  Features Intersected: US13, RD33 SB.
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 5.890,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 1729 056,  Location: FARNHURST (Lat: 39.695964,  Lng: -75.575911),  Route carried "under" structure: US 33,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 58,496 (year 2018),  Truck Traffic: 6%,  Features Intersected: US13 & I295S-US13SB RAMP,  Facility Carried by Structure: I 295 SB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 5.890,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.6m (126.6ft)

Find on map >>   Show street view

Structure Number: 1729 056,  Location: FARNHURST (Lat: 39.695964,  Lng: -75.575911),  Route carried "under" structure: Ramp Interstate 295,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 10,361 (year 2018),  Truck Traffic: 12%,  Features Intersected: US13 & I295S-US13SB RAMP
Minimum Vertical Clearance: 4.40m (14.44ft),  Kilometerpoint: 5.890,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.6m (126.6ft)