Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Yorkville, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 66ft / 20.1mTotal length
  • 60,270Total average daily traffic
  • 6,786Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Yorkville
  • No street view available for this location

New bridges in Yorkville, OH - historical statistics
  • New bridges - historical statistics
  • 11950-1959
  • 71970-1979
  • 21990-1999
Average Bridge Daily Traffic in Yorkville, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Good
  • 50.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 20.0%Good
  • 40.0%Satisfactory
  • 20.0%Fair
  • 20.0%Poor
Find on map >>   Show street view

Structure Number: 7008,  Location: 1.24 MI S OF JEF CO LINE (Lat: 40.139561,  Lng: -80.713261),  Route carried "on" structure: County highway 80470,  Year Built: 1976,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 1,949 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,705 (year 2035),  Design Load: HS 20,  Features Intersected: SR 7
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.306,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 700827,  Location: 0.53 MI.S.OF JEF.CO.LINE (Lat: 40.149861,  Lng: -80.712831),  Route carried "on" structure: State highway 7,  Year Built: 1976,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 18,497 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 25,674 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: DEEP RUN AND CO RD 2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 41.698,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 734268,  Location: 0.5 MI W OF JCT SR 7 (Lat: 40.151400,  Lng: -80.716461),  Route carried "on" structure: County highway T1074,  Year Built: 1994,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,295 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,797 (year 2035),  Design Load: HS 20,  Features Intersected: DEEP RUN,  Facility Carried by Structure: TR 1074
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 734314,  Location: 0.01 MI S OF JCT CH 2 (Lat: 40.150881,  Lng: -80.715250),  Route carried "on" structure: County highway T1076,  Year Built: 1998,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 1,295 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,797 (year 2035),  Design Load: HS 20,  Features Intersected: DEEP RUN,  Facility Carried by Structure: T 1076
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 760501,  Location: JCT CR2 & MARKET ST. (Lat: 40.150050,  Lng: -80.711811),  Route carried "on" structure: County highway MUN02,  Year Built: 1975,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 378 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 525 (year 2035),  Design Load: HS 20,  Features Intersected: DEEP RUN EXT.OF CH2,  Facility Carried by Structure: CR2 DEEP RUN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 6 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 4100018,  Location: 2.22 M S OF SR 150A (Lat: 40.159631,  Lng: -80.709239),  Route carried "on" structure: State highway 7,  Year Built: 1976,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 14,389 (year 2015),  Truck Traffic: 16%,  Average Future Daily Traffic: 19,972 (year 2035),  Design Load: HS 20,  Features Intersected: PUBLIC ROAD ST CO RD 2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.257,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4133269,  Location: E. OF INT WITH CR1 (Lat: 40.162469,  Lng: -80.741189),  Route carried "on" structure: County highway C0002,  Year Built: 1950,  Year Reconstructed: 1997,  Status: Posted for load,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 783 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,087 (year 2035),  Design Load: HL 93,  Features Intersected: LITTLE SHORT CREEK,  Facility Carried by Structure: CR2 PUBLIC RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.108,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7008,  Location: 1.24 MI S OF JEF CO LINE (Lat: 40.139561,  Lng: -80.713261),  Route carried "under" structure: State highway 7,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 18,885 (year 2016),  Truck Traffic: 11%,  Features Intersected: PICOMA ST TR-80470
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 40.547,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 700827,  Location: 0.53 MI.S.OF JEF.CO.LINE (Lat: 40.149861,  Lng: -80.712831),  Route carried "under" structure: County highway C0002,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 378 (year 2015),  Truck Traffic: 3%,  Features Intersected: SR 7,  Facility Carried by Structure: S.R.7
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 4100018,  Location: 2.22 M S OF SR 150A (Lat: 40.159631,  Lng: -80.709239),  Route carried "under" structure: County highway PUBRD,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 2,421 (year 2015),  Truck Traffic: 3%,  Features Intersected: SR7,  Facility Carried by Structure: SR 7
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Discuss Yorkville, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.