Bridge Statistics for Bellevue, Nebraska (NE)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 70Number of bridges
  • 1,460ft / 445mTotal length
  • 1,287,340Total average daily traffic
  • 40,915Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bellevue
  • No street view available for this location

New bridges in Bellevue, NE - historical statistics
  • New bridges - historical statistics
  • 71930-1939
  • 31940-1949
  • 21950-1959
  • 21960-1969
  • 71970-1979
  • 221980-1989
  • 211990-1999
  • 22000-2009
  • 32010-2019
  • 12020-2022
Reconstructed bridges in Bellevue, NE - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 11980-1989
  • 41990-1999
  • 02000-2009
  • 32010-2019
Average Bridge Daily Traffic in Bellevue, NE
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 42.5%Good
  • 37.5%Satisfactory
  • 2.5%Fair
  • 2.5%Poor
  • 2.5%Failed
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 45.0%Very good
  • 32.5%Good
  • 7.5%Satisfactory
  • 12.5%Fair
  • 2.5%Failed
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 15.0%Very good
  • 40.0%Good
  • 22.5%Satisfactory
  • 20.0%Fair
  • 2.5%Failed
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 2.2%Excellent
  • 37.8%Very good
  • 11.1%Good
  • 35.6%Satisfactory
  • 6.7%Fair
  • 6.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 10.5%Excellent
  • 26.3%Good
  • 31.6%Satisfactory
  • 21.1%Fair
  • 10.5%Poor
Find on map >>   Show street view

Structure Number: U023000410P,  Location: KASPER ST @ FT CROOK RD (Lat: 41.167400,  Lng: -95.925900),  Route carried "on" structure: City street P4,  Year Built: 1970,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 2,500 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,875 (year 2033),  Features Intersected: MUD CREEK,  Facility Carried by Structure: KASPER STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: U023000615P,  Location: CRNHSKER RD @ FT CROOK RD (Lat: 41.157300,  Lng: -95.928600),  Route carried "on" structure: City street 5006,  Year Built: 1954,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 6.74m (22.11ft),  Average Daily Traffic: 11,000 (year 2010),  Truck Traffic: 12%,  Average Future Daily Traffic: 29,000 (year 2033),  Design Load: HS 20,  Features Intersected: UP/BN/MUD CR 817-409-P,  Facility Carried by Structure: CORNHUSKER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.429,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Poor,  Operating Rating: 44.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 6.74m (22.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: U023000620P,  Location: HARVEL DR @ KAYLEEN DR (Lat: 41.151300,  Lng: -95.913300),  Route carried "on" structure: City street 5109,  Year Built: 1966,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 13,765 (year 2012),  Average Future Daily Traffic: 13,765 (year 2033),  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.684,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 6 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: U023000815P,  Location: .5NW CAPEHART (Lat: 41.133300,  Lng: -95.971700),  Route carried "on" structure: City street P8,  Year Built: 1970,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 875 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,487 (year 2033),  Features Intersected: STREAM,  Facility Carried by Structure: QUAIL DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: U023001205P,  Location: CAPEHART RD @ KENNEDY EXP (Lat: 41.118300,  Lng: -95.936700),  Route carried "on" structure: City street 5000,  Year Built: 1991,  Status: Open,  Structure Length: 10.42m (34.19ft),  Average Daily Traffic: 24,680 (year 2012),  Average Future Daily Traffic: 24,680 (year 2033),  Design Load: HS 20,  Features Intersected: BIG PAPILLION CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.349,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 0.0m,  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: U023003905,  Location: 2W OF BELLEVUE (Lat: 41.144300,  Lng: -95.966800),  Route carried "on" structure: City street 5061,  Year Built: 1984,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 9,470 (year 2007),  Average Future Daily Traffic: 9,470 (year 2033),  Design Load: HS 20,  Features Intersected: PAPILLION CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.468,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 53.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.97m (16.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: U023004103P,  Location: .2S CAPEHART (Lat: 41.116700,  Lng: -95.945000),  Route carried "on" structure: City street P41,  Year Built: 1935,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 950 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,472 (year 2033),  Features Intersected: STREAM,  Facility Carried by Structure: LYNNWOOD DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: U023010815P,  Location: .5W .7N CAPEHART (Lat: 41.137300,  Lng: -95.975600),  Route carried "on" structure: City street 108,  Year Built: 1992,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 210 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 357 (year 2033),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: COUNTY HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 84.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: U02302691,  Location: _ (Lat: 41.090936,  Lng: -95.943578),  Route carried "on" structure: City street ,  Year Built: 1935,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 200 (year 2022),  Average Future Daily Traffic: 200 (year 2025),  Features Intersected: PAPILLION CREEK TRIB,  Facility Carried by Structure: _
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Private,  Approaching Roadway Width: 7.2m (23.6ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: U023026915,  Location: _ (Lat: 41.090475,  Lng: -95.940503),  Route carried "on" structure: City street ,  Year Built: 1935,  Status: Open,  Structure Length: 1.97m (6.46ft),  Average Daily Traffic: 200 (year 2022),  Average Future Daily Traffic: 200 (year 2025),  Features Intersected: PAPILLION CREEK TRIB,  Facility Carried by Structure: _
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Private,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: U023031235,  Location: SHILLING DR @ FT CROOK RD (Lat: 41.118700,  Lng: -95.929300),  Route carried "on" structure: City street 312,  Year Built: 1935,  Status: Closed,  Structure Length: 6.46m (21.19ft),  Average Daily Traffic: 2,000 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,100 (year 2033),  Features Intersected: UP/BNSF RR 433-019-N,  Facility Carried by Structure: SHILLING DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Failed,  Superstructure: Failed,  Substructure: Failed,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 6.46m (21.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: U0230B4335,  Location: JCT N370/FT CROOK RD .2S (Lat: 41.135400,  Lng: -95.926500),  Route carried "on" structure: City street 5145,  Year Built: 1941,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 13,470 (year 2012),  Average Future Daily Traffic: 13,470 (year 2033),  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.367,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: U0230B434,  Location: JCT N370/FT CROOK RD .1S (Lat: 41.137900,  Lng: -95.926500),  Route carried "on" structure: City street 5145,  Year Built: 1941,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 13,470 (year 2012),  Average Future Daily Traffic: 13,470 (year 2033),  Design Load: HS 20,  Features Intersected: BETZ DITCH,  Facility Carried by Structure: FT CROOK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.396,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.34m (4.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: U0230B4355,  Location: FTCROOK 150' S PEOPLES RD (Lat: 41.161900,  Lng: -95.925200),  Route carried "on" structure: City street 5145,  Year Built: 1941,  Year Reconstructed: 1961,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 13,710 (year 2012),  Average Future Daily Traffic: 13,710 (year 2033),  Design Load: HS 20,  Features Intersected: MUD CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.661,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: U0230C4305,  Location: PEOPLES RD @ FT CROOK RD (Lat: 41.162600,  Lng: -95.924900),  Route carried "on" structure: City street 43,  Year Built: 1972,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 200 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 310 (year 2033),  Features Intersected: MUD CREEK,  Facility Carried by Structure: PEOPLES ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.98m (3.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: U0230C431,  Location: 500' S JCT AVERY/FT CROOK (Lat: 41.163600,  Lng: -95.924800),  Route carried "on" structure: ServiceOther road L4,  Year Built: 1935,  Year Reconstructed: 2017,  Status: Posted for load,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 250 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 387 (year 2033),  Features Intersected: MUD CREEK,  Facility Carried by Structure: ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 24.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 17.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.16m (3.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: U0230C4315,  Location: 150' S JCT AVERY/FT C (Lat: 41.164600,  Lng: -95.924800),  Route carried "on" structure: ServiceOther road K4,  Year Built: 1935,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 250 (year 2003),  Truck Traffic: 10%,  Average Future Daily Traffic: 387 (year 2033),  Features Intersected: MUD CREEK,  Facility Carried by Structure: ACCESS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: U0230F4305,  Location: BETZ RD @ N370 (Lat: 41.140700,  Lng: -95.922100),  Route carried "on" structure: City street 5107,  Year Built: 1988,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 2,820 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,820 (year 2033),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.098,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: S075 08037L,  Location: JCT US 75/CAPEHART RD (Lat: 41.117800,  Lng: -95.934900),  Route carried "under" structure: County highway 5000,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 24,680 (year 2012),  Features Intersected: FAU 5000/CAPEHART RD,  Facility Carried by Structure: SB-US75
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 16.375,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: S075 08037R,  Location: JCT US 75/CAPEHART RD (Lat: 41.117800,  Lng: -95.934600),  Route carried "under" structure: County highway 5000,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 24,680 (year 2012),  Features Intersected: FAU 5000/CAPEHART RD,  Facility Carried by Structure: NB-US75
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 16.372,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: S075 08192L,  Location: JCT US75/N370 (Lat: 41.140000,  Lng: -95.937300),  Route carried "under" structure: State highway 370,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 34,435 (year 2012),  Truck Traffic: 1%,  Features Intersected: N370,  Facility Carried by Structure: SB-US75
Minimum Vertical Clearance: 5.10m (16.73ft),  Kilometerpoint: 2.572,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.9m (107.9ft)

Find on map >>   Show street view

Structure Number: S075 08192R,  Location: JCT US75/N370 (Lat: 41.140000,  Lng: -95.937000),  Route carried "under" structure: State highway 370,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 25,745 (year 2012),  Truck Traffic: 2%,  Features Intersected: N370,  Facility Carried by Structure: NB-US75
Minimum Vertical Clearance: 5.10m (16.73ft),  Kilometerpoint: 2.575,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.9m (107.9ft)

Find on map >>   Show street view

Structure Number: S075 08323,  Location: CORNHUSKER RD @ US75 (Lat: 41.158900,  Lng: -95.938700),  Route carried "under" structure: US 75,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 58,550 (year 2012),  Truck Traffic: 4%,  Features Intersected: US75,  Facility Carried by Structure: CORNHUSKER ROAD
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 13.395,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.5m (123.0ft)

Find on map >>   Show street view

Structure Number: S075 08324,  Location: CRNHSKER RD @ US75 (Lat: 41.159000,  Lng: -95.939000),  Route carried "under" structure: US 75,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 53,350 (year 2008),  Truck Traffic: 4%,  Features Intersected: US75,  Facility Carried by Structure: PEDESTRIAN OVRPASS
Minimum Vertical Clearance: 6.42m (21.06ft),  Kilometerpoint: 13.393,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.5m (123.0ft)

Find on map >>   Show street view

Structure Number: S075 08444,  Location: US75/CHILDS ROAD (Lat: 41.176500,  Lng: -95.939700),  Route carried "under" structure: US 75,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 58,550 (year 2012),  Truck Traffic: 4%,  Features Intersected: US75,  Facility Carried by Structure: FAU 5012/CHILDS RD
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 13.589,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: S075 08495L,  Location: JCT US75/CHANDLER RD (Lat: 41.183700,  Lng: -95.938100),  Route carried "under" structure: City street 5020,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 10,345 (year 2012),  Truck Traffic: 4%,  Features Intersected: FAU 5020/CHANDLER RD,  Facility Carried by Structure: SB-US75
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 16.340,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: S075 08495R,  Location: JCT US75/CHANDLER RD (Lat: 41.183700,  Lng: -95.937900),  Route carried "under" structure: City street 5020,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 10,345 (year 2012),  Truck Traffic: 4%,  Features Intersected: FAU 5020/CHANDLER RD,  Facility Carried by Structure: NB-US75
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 16.343,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: S370 01654,  Location: FT CROOK RD/N370 INTRCHG (Lat: 41.140200,  Lng: -95.926500),  Route carried "under" structure: City street 5145,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 10,380 (year 2012),  Features Intersected: FT CROOK RD/FAU 5145,  Facility Carried by Structure: CITY STREET
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 16.422,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 59.4m (194.9ft)

Find on map >>   Show street view

Structure Number: U0230A081,  Location: GALVIN @ HANSEN (Lat: 41.146700,  Lng: -95.913300),  Route carried "under" structure: City street 5006,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2006),  Features Intersected: PEDESTRIAN OVERPASS,  Facility Carried by Structure: PEDESTRIAN OVRPASS
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 17.602,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.2m (131.9ft)