Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Burlington, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 76Number of bridges
  • 669ft / 204mTotal length
  • 1,191,970Total average daily traffic
  • 160,365Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Burlington
  • No street view available for this location

New bridges in Burlington, NC - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21930-1939
  • 111950-1959
  • 81960-1969
  • 61970-1979
  • 81980-1989
  • 161990-1999
  • 142000-2009
  • 102010-2019
Reconstructed bridges in Burlington, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 21950-1959
  • 11960-1969
  • 11970-1979
  • 21980-1989
  • 01990-1999
  • 22000-2009
Average Bridge Daily Traffic in Burlington, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 17.1%Very good
  • 51.2%Good
  • 19.5%Satisfactory
  • 9.8%Fair
  • 2.4%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 31.7%Very good
  • 39.0%Good
  • 14.6%Satisfactory
  • 9.8%Fair
  • 4.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 31.7%Very good
  • 29.3%Good
  • 22.0%Satisfactory
  • 14.6%Fair
  • 2.4%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 1.6%Very good
  • 85.7%Good
  • 9.5%Satisfactory
  • 3.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 23.1%Good
  • 61.5%Satisfactory
  • 15.4%Fair
Find on map >>   Show street view

Structure Number: 10415,  Location: .4 MI.N.JCT.GARDEN RD. (Lat: 36.074658,  Lng: -79.498011),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 1,000 (year 1999),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,000 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: GUM CREEK,  Facility Carried by Structure: BOONE STATION DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 10422,  Location: 0.25 MI. E. SR1301 (Lat: 36.067525,  Lng: -79.511686),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 100 (year 2008),  Truck Traffic: 7%,  Average Future Daily Traffic: 200 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: ALAMANCE CROSSING,  Facility Carried by Structure: BOONE STATION DR.
Minimum Vertical Clearance: 0.00m,  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.3m (56.8ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 18.5m (60.7ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10423,  Location: 0.1MI.W.JCT.DUNLEIGH DR. (Lat: 36.072819,  Lng: -79.533792),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 100 (year 2008),  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WATERFORD LAKE,  Facility Carried by Structure: NIRE VALLEY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10424,  Location: .1MI.W.JCT.GLENKIRK DRIVE (Lat: 36.053961,  Lng: -79.535103),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 200 (year 2008),  Truck Traffic: 7%,  Average Future Daily Traffic: 400 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: BACK CREEK,  Facility Carried by Structure: BONNAR BRG. PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10425,  Location: .1MI.E.JCT.BUXTON ROAD (Lat: 36.060994,  Lng: -79.525467),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 1.61m (5.28ft),  Average Daily Traffic: 6,400 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DANBROOK CREEK,  Facility Carried by Structure: BONNAR BRG.PKWY
Minimum Vertical Clearance: 0.00m,  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10426,  Location: .3MI.S.JCT.UNIVERSITY DR. (Lat: 36.073422,  Lng: -79.532086),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 150 (year 2008),  Truck Traffic: 6%,  Average Future Daily Traffic: 300 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRIB.MICHAELS BRANCH,  Facility Carried by Structure: DUNLEIGH DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 810038,  Location: 1.0 MI. N. JCT. NC62 (Lat: 35.996664,  Lng: -79.561372),  Route carried "on" structure: State highway 61,  Year Built: 2016,  Status: Open,  Structure Length: 3.10m (10.17ft),  Average Daily Traffic: 1,900 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,800 (year 2040),  Design Load: HL 93,  Features Intersected: BEAVER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 61),  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 810075,  Location: 1.8 MI. N. JCT. SR3127 (Lat: 36.037819,  Lng: -79.577842),  Route carried "on" structure: State highway 61,  Year Built: 1985,  Status: Open,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 2,500 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BIG ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: May 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 81013,  Location: 0.9 MI. S. JCT. SR3224 (Lat: 36.051856,  Lng: -79.569575),  Route carried "on" structure: State highway 61,  Year Built: 1985,  Status: Open,  Structure Length: 8.80m (28.87ft),  Average Daily Traffic: 2,500 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,000 (year 2040),  Features Intersected: LITTLE ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: May 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 810151,  Location: 0.3 MI. N JCT. SR1005 (Lat: 35.968686,  Lng: -79.573783),  Route carried "on" structure: State highway 62,  Year Built: 2015,  Status: Open,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 2,400 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,800 (year 2040),  Design Load: HL 93,  Features Intersected: CHOCOLATE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 810212,  Location: 0.6 MI. S. JCT. SR3257 (Lat: 36.037614,  Lng: -79.595508),  Route carried "on" structure: State highway 3056,  Year Built: 1980,  Status: Open,  Structure Length: 7.31m (23.98ft),  Average Daily Traffic: 850 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,700 (year 2040),  Design Load: HS 15,  Features Intersected: BIG ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.6m (57.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: July 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 810214,  Location: 1.2 MI. E. JCT. SR3056 (Lat: 36.056739,  Lng: -79.587394),  Route carried "on" structure: State highway 3058,  Year Built: 1956,  Status: Closed,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 70 (year 1988),  Average Future Daily Traffic: 140 (year 2040),  Features Intersected: LITTLE ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.2m (13.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 13.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 8.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2020,  Underwater Inspection Date: March 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 810219,  Location: 0.3 MI.E.JCT.W.SR1310 (Lat: 36.002606,  Lng: -79.553289),  Route carried "on" structure: State highway 3111,  Year Built: 1950,  Status: Posted for load,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 850 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,700 (year 2040),  Features Intersected: BEAVER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 32.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 810222,  Location: 0.75 MI. N. JCT. SR3127 (Lat: 36.047322,  Lng: -79.551106),  Route carried "on" structure: State highway 3066,  Year Built: 1985,  Status: Open,  Structure Length: 7.58m (24.87ft),  Average Daily Traffic: 420 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 840 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Channel: Good,  Operating Rating: 21.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 12.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: May 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 810228,  Location: 0.4 MI. N. JCT. SR3093 (Lat: 36.015269,  Lng: -79.625069),  Route carried "on" structure: State highway 3045,  Year Built: 2009,  Status: Open,  Structure Length: 6.09m (19.98ft),  Average Daily Traffic: 1,800 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,600 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.5m (96.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 63.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 810229,  Location: 0.3 MI. S. OF JCT. SR3117 (Lat: 35.977119,  Lng: -79.542431),  Route carried "on" structure: State highway 3118,  Year Built: 2017,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 100 (year 2017),  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: N. PR. STINKING QTR. CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.7m (90.9ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 69.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 810246,  Location: 0.7 MI. N. JCT. SR3093 (Lat: 35.996772,  Lng: -79.637386),  Route carried "on" structure: State highway 3088,  Year Built: 1998,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 100 (year 1984),  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 810247,  Location: 1.0 MILE WEST OF SR3093 (Lat: 35.998906,  Lng: -79.642814),  Route carried "on" structure: State highway 3088,  Year Built: 2018,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 670 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,340 (year 2040),  Design Load: HL 93,  Features Intersected: BIG ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 810248,  Location: 0.15 MI. W. JCT. SR3086 (Lat: 36.007119,  Lng: -79.653386),  Route carried "on" structure: State highway 3088,  Year Built: 2014,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 670 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,340 (year 2025),  Design Load: HL 93,  Features Intersected: BIG ALAMANCE TRIBUTARY 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 81025,  Location: 1.0 MI. W. JCT. SR3093 (Lat: 36.007233,  Lng: -79.639358),  Route carried "on" structure: State highway 3092,  Year Built: 2005,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 210 (year 2000),  Truck Traffic: 6%,  Average Future Daily Traffic: 420 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BIG ALAMANCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 810251,  Location: 0.7 MI. N. JCT. SR1005 (Lat: 35.990289,  Lng: -79.636653),  Route carried "on" structure: State highway 3616,  Year Built: 1956,  Status: Posted for load,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 270 (year 2000),  Truck Traffic: 6%,  Average Future Daily Traffic: 540 (year 2040),  Features Intersected: BR. OF BIG ALAMANCE CK.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.6m (18.4ft),  Out-to-Out Width: 5.9m (19.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 37.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 810252,  Location: 1.4 MI. S. JCT. SR3111 (Lat: 35.979692,  Lng: -79.588042),  Route carried "on" structure: State highway 3045,  Year Built: 1989,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 1,600 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BEAVER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 81032,  Location: 0.6 MI. N. JCT. SR3118 (Lat: 35.979892,  Lng: -79.557297),  Route carried "on" structure: State highway 3121,  Year Built: 2008,  Status: Open,  Structure Length: 3.59m (11.78ft),  Average Daily Traffic: 440 (year 2000),  Truck Traffic: 6%,  Average Future Daily Traffic: 880 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: STINKING QUARTER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.1m (52.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10047,  Location: 0.96 MI. W. JCT. SR1158 (Lat: 36.065378,  Lng: -79.515689),  Route carried "under" structure: Interstate 40,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1226
Minimum Vertical Clearance: 5.96m (19.55ft),  Kilometerpoint: 42.672,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.9m (130.9ft)

Find on map >>   Show street view

Structure Number: 10047,  Location: 0.96 MI. W. JCT. SR1158 (Lat: 36.065378,  Lng: -79.515689),  Route carried "under" structure: Interstate 40,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1226
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 42.672,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.9m (130.9ft)

Find on map >>   Show street view

Structure Number: 10075,  Location: .27M. N. JCT. SR1216 (Lat: 36.067386,  Lng: -79.498325),  Route carried "under" structure: Interstate 40,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1158
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 43.129,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 10075,  Location: .27M. N. JCT. SR1216 (Lat: 36.067386,  Lng: -79.498325),  Route carried "under" structure: Interstate 40,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1158
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 43.129,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 10076,  Location: 1.08 MI. S. JCT. SR1154 (Lat: 36.065144,  Lng: -79.468975),  Route carried "under" structure: State highway 62,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2019),  Truck Traffic: 6%,  Features Intersected: I40 ,I85
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 10115,  Location: 1.0 MI. N. JCT. NC62 (Lat: 36.064872,  Lng: -79.449744),  Route carried "under" structure: Interstate 40,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 66,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1154
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 43.937,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 10115,  Location: 1.0 MI. N. JCT. NC62 (Lat: 36.064872,  Lng: -79.449744),  Route carried "under" structure: Interstate 40,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 66,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1154
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 43.937,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 1012,  Location: 1.8 MI. S. JCT. NC87 (Lat: 36.063761,  Lng: -79.431150),  Route carried "under" structure: State highway 49,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 9,500 (year 2015),  Truck Traffic: 6%,  Features Intersected: I40,I85
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.1m (52.8ft)

Find on map >>   Show street view

Structure Number: 1012,  Location: 1.8 MI. S. JCT. NC87 (Lat: 36.063761,  Lng: -79.431150),  Route carried "under" structure: State highway 49,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 9,500 (year 2015),  Truck Traffic: 6%,  Features Intersected: I40,I85
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.1m (52.8ft)

Discuss Burlington, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.