Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Centralia, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 49Number of bridges
  • 554ft / 169mTotal length
  • $1,291,000Total costs
  • 102,400Total average daily traffic
  • 6,865Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Centralia
  • No street view available for this location

New bridges in Centralia, IL - historical statistics
  • New bridges - historical statistics
  • 51900-1909
  • 11930-1939
  • 21940-1949
  • 31950-1959
  • 21960-1969
  • 121970-1979
  • 81980-1989
  • 101990-1999
  • 32000-2009
  • 32010-2019
Average Bridge Daily Traffic in Centralia, IL
Average Bridge Truck Traffic in Centralia, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 34.3%Very good
  • 48.6%Good
  • 11.4%Satisfactory
  • 5.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 31.4%Very good
  • 40.0%Good
  • 20.0%Satisfactory
  • 8.6%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 28.6%Very good
  • 45.7%Good
  • 20.0%Satisfactory
  • 2.9%Poor
  • 2.9%Critical
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 2.4%Excellent
  • 9.5%Very good
  • 57.1%Good
  • 21.4%Satisfactory
  • 7.1%Fair
  • 2.4%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 18.2%Very good
  • 54.5%Good
  • 27.3%Satisfactory
Find on map >>   Show street view

Structure Number: 95313,  Location: 5 MI NW OFIRVINGTON (Lat: 38.496647,  Lng: -89.218258),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 50 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 81 (year 2032),  Design Load: HS 20,  Features Intersected: GRAND POINT CREEK,  Facility Carried by Structure: TR 0001
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.720,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 953205,  Location: 0.7 MI N OF NOLTINGS (Lat: 38.496142,  Lng: -89.199869),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 376 (year 2032),  Design Load: HS 20,  Features Intersected: SEWER CREEK,  Facility Carried by Structure: CH 18
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.046,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 953215,  Location: 0.5 MI N OF NOLTINGS (Lat: 38.492722,  Lng: -89.199875),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 525 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 349 (year 2032),  Design Load: HS 20,  Features Intersected: WEBSTER CREEK,  Facility Carried by Structure: CH 18
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.416,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 953228,  Location: NORTH OF NOLTINGS (Lat: 38.493444,  Lng: -89.199872),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 525 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 349 (year 2032),  Design Load: HS 20,  Features Intersected: WEBSTER CK OVERFLOW,  Facility Carried by Structure: CH 18
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.336,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 953229,  Location: NORTH OF NOLTINGS (Lat: 38.496453,  Lng: -89.199869),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 376 (year 2032),  Design Load: HS 20,  Features Intersected: SEWER CREEK OVERFLOW,  Facility Carried by Structure: CH 18
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.014,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 610079,  Location: MCCORD ST CENTRALIA (Lat: 38.530839,  Lng: -89.137208),  Route carried "under" structure: City street ,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 650 (year 2017),  Truck Traffic: 8%,  Features Intersected: ST-6800 & ICG/BN RR,  Facility Carried by Structure: IL 161 WB - FAP 80
Minimum Vertical Clearance: 7.92m (25.98ft),  Kilometerpoint: 0.772,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 616003,  Location: CENTRALIA (Lat: 38.529192,  Lng: -89.135342),  Route carried "under" structure: State highway 161,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 7,100 (year 2021),  Truck Traffic: 5%,  Features Intersected: FAP-805 (ILL-161),  Facility Carried by Structure: OAK STREET 6900
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 88.528,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 11.9m (39.0ft)

Find on map >>   Show street view

Structure Number: 619912,  Location: CENTRALIA (Lat: 38.529339,  Lng: -89.136156),  Route carried "under" structure: State highway 161,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 7,100 (year 2021),  Truck Traffic: 5%,  Features Intersected: FAP-805 (ILL-161),  Facility Carried by Structure: SOUTHERN,IC,&CB&Q
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 88.479,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 11.9m (39.0ft)

Discuss Centralia, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.