Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Chapel Hill, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 65Number of bridges
  • 410ft / 125mTotal length
  • 991,420Total average daily traffic
  • 123,989Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Chapel Hill
  • No street view available for this location

New bridges in Chapel Hill, NC - historical statistics
  • New bridges - historical statistics
  • 31940-1949
  • 141950-1959
  • 81960-1969
  • 21970-1979
  • 191980-1989
  • 121990-1999
  • 62000-2009
  • 12010-2019
Reconstructed bridges in Chapel Hill, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21960-1969
  • 01970-1979
  • 41980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Chapel Hill, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.5%Very good
  • 36.4%Good
  • 18.2%Satisfactory
  • 40.9%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 4.5%Very good
  • 22.7%Good
  • 36.4%Satisfactory
  • 31.8%Fair
  • 4.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 4.5%Very good
  • 31.8%Good
  • 18.2%Satisfactory
  • 45.5%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 55.0%Good
  • 5.0%Satisfactory
  • 35.0%Fair
  • 5.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 35.7%Good
  • 25.0%Satisfactory
  • 35.7%Fair
  • 3.6%Poor
Find on map >>   Show street view

Structure Number: 1350321,  Location: .1 MI.S.JCT.BROOKVIEW DR. (Lat: 35.950825,  Lng: -79.033492),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 3,000 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 6,000 (year 2040),  Features Intersected: CEDAR FORK CREEK,  Facility Carried by Structure: NORTH LAKESHORE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 74.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1350329,  Location: 0.1 MI.E.JCT.GRAYLYN DR. (Lat: 35.880917,  Lng: -79.069561),  Route carried "on" structure: City street ,  Year Built: 2004,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 800 (year 2005),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HS 20,  Features Intersected: FAN BRANCH CREEK,  Facility Carried by Structure: ABERDEEN ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.0m (19.7ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1350331,  Location: 0.1 MI.W.EDGEWATER CIR. (Lat: 35.883969,  Lng: -79.069783),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 800 (year 2005),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HS 20,  Features Intersected: FAN BRANCH CREEK,  Facility Carried by Structure: BROOKGREEN DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.0m (19.7ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1350332,  Location: 0.1 MI.W.EDGEWATER CIR. (Lat: 35.882997,  Lng: -79.070097),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 800 (year 2005),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HS 20,  Features Intersected: FAN BRANCH CREEK,  Facility Carried by Structure: GRAYLYN DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.0m (19.7ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1350333,  Location: 0.1 MI.W.JCT.EDGEWATER CR (Lat: 35.885383,  Lng: -79.067817),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 800 (year 2005),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HS 20,  Features Intersected: FAN BRANCH CREEK,  Facility Carried by Structure: PARKVIEW CRESENT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.0m (19.7ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1350334,  Location: 0.1 MI.N.PEBBLE SPRING DR (Lat: 35.957058,  Lng: -79.019161),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Posted for load,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 800 (year 2005),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DRY CREEK,  Facility Carried by Structure: PERRY CREEK DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 79.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1350005,  Location: 0.19 MI. N. JCT. SR1008 (Lat: 35.893467,  Lng: -79.057439),  Route carried "under" structure: State highway 54,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 16,500 (year 2015),  Truck Traffic: 12%,  Features Intersected: US15/US501
Minimum Vertical Clearance: 6.24m (20.47ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 1350005,  Location: 0.19 MI. N. JCT. SR1008 (Lat: 35.893467,  Lng: -79.057439),  Route carried "under" structure: State highway 54,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 16,500 (year 2015),  Truck Traffic: 12%,  Features Intersected: US15/US501
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 1350041,  Location: 0.95 MI. N. JCT. SR1750 (Lat: 35.938686,  Lng: -79.023286),  Route carried "under" structure: US 15,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 21,500 (year 2017),  Truck Traffic: 12%,  Features Intersected: SR1010 NBL
Minimum Vertical Clearance: 4.26m (13.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 1350045,  Location: 0.6 MI. N. JCT. SR1900 (Lat: 35.908706,  Lng: -79.027292),  Route carried "under" structure: State highway 54,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: US15,US501S
Minimum Vertical Clearance: 4.56m (14.96ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 1350045,  Location: 0.6 MI. N. JCT. SR1900 (Lat: 35.908706,  Lng: -79.027292),  Route carried "under" structure: State highway 54,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: US15,US501S
Minimum Vertical Clearance: 4.58m (15.03ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 1350258,  Location: 0.7 MI. N. JCT. SR1733 (Lat: 35.959889,  Lng: -79.012597),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 40,500 (year 2018),  Truck Traffic: 16%,  Features Intersected: SR1734
Minimum Vertical Clearance: 6.01m (19.72ft),  Kilometerpoint: 81.992,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1350258,  Location: 0.7 MI. N. JCT. SR1733 (Lat: 35.959889,  Lng: -79.012597),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 40,500 (year 2018),  Truck Traffic: 16%,  Features Intersected: SR1734
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 81.992,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1350259,  Location: 0.3 MI. N. JCT. SR1733 (Lat: 35.969303,  Lng: -79.033850),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 40,500 (year 2018),  Truck Traffic: 16%,  Features Intersected: SR1732
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.2m (95.8ft)

Find on map >>   Show street view

Structure Number: 1350259,  Location: 0.3 MI. N. JCT. SR1733 (Lat: 35.969303,  Lng: -79.033850),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 40,500 (year 2018),  Truck Traffic: 16%,  Features Intersected: SR1732
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.2m (95.8ft)

Find on map >>   Show street view

Structure Number: 1350264,  Location: 1.3 MI. W. JCT. NC86 (Lat: 35.987086,  Lng: -79.075033),  Route carried "under" structure: State highway 1725,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 2,700 (year 2017),  Truck Traffic: 6%,  Features Intersected: I40 WBL
Minimum Vertical Clearance: 6.98m (22.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 1350265,  Location: 1.7 MI. E. JCT. SR1723 (Lat: 35.986764,  Lng: -79.075211),  Route carried "under" structure: State highway 1725,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 2,700 (year 2017),  Truck Traffic: 7%,  Features Intersected: I40 EBL
Minimum Vertical Clearance: 7.31m (23.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.8m (61.7ft)

Find on map >>   Show street view

Structure Number: 1350266,  Location: 0.1 MI. S. JCT. SR1730 (Lat: 35.971072,  Lng: -79.062600),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 37,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: NC86
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1350266,  Location: 0.1 MI. S. JCT. SR1730 (Lat: 35.971072,  Lng: -79.062600),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 37,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: NC86
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1350281,  Location: 1.2 MI. S. JCT. SR1750 (Lat: 35.908656,  Lng: -79.027131),  Route carried "under" structure: State highway 54,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2017),  Truck Traffic: 12%,  Features Intersected: US15/501N
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Find on map >>   Show street view

Structure Number: 1350281,  Location: 1.2 MI. S. JCT. SR1750 (Lat: 35.908656,  Lng: -79.027131),  Route carried "under" structure: State highway 54,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2017),  Truck Traffic: 12%,  Features Intersected: US15/501N
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Discuss Chapel Hill, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.