Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Chicago, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 1,288Number of bridges
  • 22,359ft / 6,815mTotal length
  • $1,244,483,000Total costs
  • 60,573,280Total average daily traffic
  • 3,993,040Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Chicago
  • No street view available for this location

New bridges in Chicago, IL - historical statistics
  • New bridges - historical statistics
  • 2Before 1900
  • 1741900-1909
  • 561910-1919
  • 481920-1929
  • 521930-1939
  • 271940-1949
  • 3611950-1959
  • 2541960-1969
  • 231970-1979
  • 511980-1989
  • 831990-1999
  • 642000-2009
  • 902010-2019
  • 12020-2022
Reconstructed bridges in Chicago, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 11950-1959
  • 61960-1969
  • 291970-1979
  • 1091980-1989
  • 1401990-1999
  • 772000-2009
  • 152010-2019
  • 32020-2022
Average Bridge Daily Traffic in Chicago, IL
Average Bridge Truck Traffic in Chicago, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.2%Excellent
  • 6.4%Very good
  • 33.1%Good
  • 33.1%Satisfactory
  • 20.8%Fair
  • 5.0%Poor
  • 0.4%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.4%Excellent
  • 15.4%Very good
  • 25.4%Good
  • 26.3%Satisfactory
  • 20.6%Fair
  • 7.4%Poor
  • 3.1%Serious
  • 0.3%Critical
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.2%Excellent
  • 13.3%Very good
  • 28.9%Good
  • 30.8%Satisfactory
  • 19.0%Fair
  • 4.8%Poor
  • 1.9%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.3%Excellent
  • 33.6%Very good
  • 35.5%Good
  • 18.2%Satisfactory
  • 4.5%Fair
  • 0.9%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 8.3%Very good
  • 8.3%Good
  • 58.3%Satisfactory
  • 25.0%Fair
Find on map >>   Show street view

Structure Number: 160734,  Location: 1.52 M S ILL 64 P4C (Lat: 41.888711,  Lng: -87.725889),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 17,100 (year 2021),  Truck Traffic: 8%,  Features Intersected: PULASKI RD,  Facility Carried by Structure: C&NW RR (3 OF 5)
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 20.937,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 160735,  Location: 1.53 M S ILL 64 P4C (Lat: 41.888561,  Lng: -87.725883),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 17,100 (year 2021),  Truck Traffic: 8%,  Features Intersected: PULASKI RD,  Facility Carried by Structure: C&NW RR (4 OF 5)
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 20.953,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 160736,  Location: 1.54 M S ILL 64 P4C (Lat: 41.888414,  Lng: -87.725878),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 17,100 (year 2021),  Truck Traffic: 8%,  Features Intersected: PULASKI RD,  Facility Carried by Structure: C&NW RR (5 OF 5)
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 20.969,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 12.5m (41.0ft)

Find on map >>   Show street view

Structure Number: 160737,  Location: 0.75 M N I290 P4C (Lat: 41.885439,  Lng: -87.725800),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 17,100 (year 2021),  Truck Traffic: 8%,  Features Intersected: PULASKI RD,  Facility Carried by Structure: LAKE ST CTA
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 21.291,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 160738,  Location: 2.7 M W US 34 (Lat: 41.873750,  Lng: -87.725447),  Route carried "under" structure: Interstate 290,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 195,200 (year 2021),  Truck Traffic: 4%,  Features Intersected: I-290 IKE & CTA,  Facility Carried by Structure: PULASKI RD
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 41.295,  Lanes on structure: 5,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 160739,  Location: 0.4 M S I290 P4C (Lat: 41.867869,  Lng: -87.725206),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 15,200 (year 2021),  Truck Traffic: 5%,  Features Intersected: PULASKI RD,  Facility Carried by Structure: CSX-RR
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 23.206,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 16074,  Location: 1.4 M S I290 P4C (Lat: 41.853608,  Lng: -87.724819),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 14,800 (year 2021),  Truck Traffic: 6%,  Features Intersected: PULASKI RD,  Facility Carried by Structure: DOUGLAS PK CTA
Minimum Vertical Clearance: 4.14m (13.58ft),  Kilometerpoint: 24.783,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 14.0m (45.9ft)

Find on map >>   Show street view

Structure Number: 160744,  Location: 0.92 M S OF 31ST ST (Lat: 41.822986,  Lng: -87.724053),  Route carried "under" structure: Interstate 55,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 76,500 (year 2021),  Truck Traffic: 15%,  Features Intersected: I- 55 STEVENSON,  Facility Carried by Structure: PULASKI RD & RAMPS
Minimum Vertical Clearance: 6.20m (20.34ft),  Kilometerpoint: 463.221,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Find on map >>   Show street view

Structure Number: 160753,  Location: 0.6 M N I290 P4C (Lat: 41.884181,  Lng: -87.701300),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 16,600 (year 2021),  Truck Traffic: 3%,  Features Intersected: SACRAMENTO BLVD,  Facility Carried by Structure: LAKE ST CTA
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 6.534,  Lanes under structure: 4,  Material/Design: Concrete,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 160754,  Location: 1.4 M W US 34 (Lat: 41.874981,  Lng: -87.701047),  Route carried "under" structure: Interstate 290,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 180,800 (year 2021),  Truck Traffic: 4%,  Features Intersected: I-290 IKE & CTA,  Facility Carried by Structure: SACRAMENTO BLVD
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 43.290,  Lanes on structure: 5,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 160755,  Location: 0.45 M S I290 P4C (Lat: 41.868761,  Lng: -87.700861),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2021),  Truck Traffic: 2%,  Features Intersected: SACRAMENTO BLVD,  Facility Carried by Structure: B&OCT RR
Minimum Vertical Clearance: 4.09m (13.42ft),  Kilometerpoint: 8.256,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 10.7m (35.1ft)

Find on map >>   Show street view

Structure Number: 160756,  Location: 0.3 M S I55 P4C (Lat: 41.825783,  Lng: -87.694669),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 12,400 (year 2018),  Truck Traffic: 18%,  Features Intersected: CALIFORNIA BLVD,  Facility Carried by Structure: GM&O RR
Minimum Vertical Clearance: 4.01m (13.16ft),  Kilometerpoint: 6.791,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160757,  Location: 1.82 M S I55 P6C (Lat: 41.804706,  Lng: -87.694092),  Route carried "under" structure: Other road ,  Year Built: 1937,  Structure Length: 0. m,  Average Daily Traffic: 14,300 (year 2018),  Truck Traffic: 5%,  Features Intersected: CALIFORNIA BLVD,  Facility Carried by Structure: IHB RR(NORTH)
Minimum Vertical Clearance: 4.04m (13.25ft),  Kilometerpoint: 9.157,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 14.3m (46.9ft)

Find on map >>   Show street view

Structure Number: 160758,  Location: 1.84 M S I55 P6C (Lat: 41.804383,  Lng: -87.694083),  Route carried "under" structure: Other road ,  Year Built: 1937,  Structure Length: 0. m,  Average Daily Traffic: 14,300 (year 2018),  Truck Traffic: 5%,  Features Intersected: CALIFORNIA BLVD,  Facility Carried by Structure: IHB RR (SOUTH)
Minimum Vertical Clearance: 4.04m (13.25ft),  Kilometerpoint: 9.189,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 14.3m (46.9ft)

Find on map >>   Show street view

Structure Number: 160763,  Location: 1.66 M NW ILL 64 P3C (Lat: 41.927667,  Lng: -87.672817),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 9,150 (year 2021),  Truck Traffic: 2%,  Features Intersected: CLYBOURN AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.04m (13.25ft),  Kilometerpoint: 1.835,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 160764,  Location: 0.96 M N I55 P5C (Lat: 41.862436,  Lng: -87.639097),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 17,500 (year 2021),  Truck Traffic: 4%,  Features Intersected: CANAL ST,  Facility Carried by Structure: B&OCT RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 1.802,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 13.1m (43.0ft)

Find on map >>   Show street view

Structure Number: 160768,  Location: 0.34 M S I55 P5C (Lat: 41.851939,  Lng: -87.638506),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 12,100 (year 2021),  Truck Traffic: 3%,  Features Intersected: CANAL ST,  Facility Carried by Structure: AT&SF RR
Minimum Vertical Clearance: 3.86m (12.66ft),  Kilometerpoint: 2.832,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 160769,  Location: 2.5 M N US 12&20 P4 (Lat: 41.757981,  Lng: -87.649067),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 2,100 (year 2021),  Truck Traffic: 1%,  Features Intersected: MORGAN ST,  Facility Carried by Structure: CHB RR
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 2.430,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 16077,  Location: 0.8 M N US 12&20 P4 (Lat: 41.732656,  Lng: -87.646503),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 9,850 (year 2018),  Truck Traffic: 6%,  Features Intersected: VINCINNES AVE,  Facility Carried by Structure: CRI&P RR
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 4.377,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 160781,  Location: 0.9 M N I290 P5C (Lat: 41.888564,  Lng: -87.667117),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 18,600 (year 2021),  Truck Traffic: 7%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.04m (13.25ft),  Kilometerpoint: 20.502,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 160782,  Location: 0.62 M N I290 P5C (Lat: 41.885325,  Lng: -87.666992),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 18,600 (year 2021),  Truck Traffic: 7%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: LAKE ST CTA
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 20.873,  Lanes under structure: 5,  Material/Design: Steel,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 160783,  Location: 1 M W IL 1 (Lat: 41.875511,  Lng: -87.666714),  Route carried "under" structure: Interstate 290,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 159,400 (year 2021),  Truck Traffic: 5%,  Features Intersected: I-290 IKE & CTA,  Facility Carried by Structure: ASHLAND AVE
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 46.139,  Lanes on structure: 7,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 160784,  Location: 1.07 M S I290 P5C (Lat: 41.861006,  Lng: -87.666247),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 23,100 (year 2021),  Truck Traffic: 7%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: B&OCT RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 23.592,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160785,  Location: 1.14 M S I290 P5C (Lat: 41.860133,  Lng: -87.666222),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 23,100 (year 2021),  Truck Traffic: 7%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 23.689,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160787,  Location: 0.5 M N I55 P5C (Lat: 41.838903,  Lng: -87.665767),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 22,300 (year 2021),  Truck Traffic: 9%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: AT&SF RR
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 26.006,  Lanes under structure: 5,  Material/Design: Steel,  Length of Maximum Span: 12.2m (40.0ft)

Find on map >>   Show street view

Structure Number: 160789,  Location: 1.35 M S I55 P7C (Lat: 41.819892,  Lng: -87.665353),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 26,900 (year 2018),  Truck Traffic: 16%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: C&J RR
Minimum Vertical Clearance: 4.17m (13.68ft),  Kilometerpoint: 28.114,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 16079,  Location: 2.4 M S I55 P7C (Lat: 41.804658,  Lng: -87.664950),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 22,800 (year 2018),  Truck Traffic: 10%,  Features Intersected: ASHLAND AVE,  Facility Carried by Structure: IHB RR
Minimum Vertical Clearance: 4.01m (13.16ft),  Kilometerpoint: 29.820,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 160797,  Location: 0.2 M N I90 P7C (Lat: 41.772147,  Lng: -87.615433),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 11,900 (year 2018),  Truck Traffic: 7%,  Features Intersected: LUTHER KING DR,  Facility Carried by Structure: NYC RR
Minimum Vertical Clearance: 4.01m (13.16ft),  Kilometerpoint: 8.819,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160798,  Location: 0.1 M N I90 P7C (Lat: 41.771739,  Lng: -87.615425),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 11,900 (year 2018),  Truck Traffic: 7%,  Features Intersected: LUTHER KING DR,  Facility Carried by Structure: PC RR
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 8.867,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160799,  Location: 2.3 M N ILL 83 P4,8C (Lat: 41.659089,  Lng: -87.618069),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2021),  Truck Traffic: 6%,  Features Intersected: INDIANA AVE,  Facility Carried by Structure: IC RR
Minimum Vertical Clearance: 4.06m (13.32ft),  Kilometerpoint: 29.563,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 16.2m (53.1ft)

Find on map >>   Show street view

Structure Number: 160802,  Location: 0.1 M N US 12&20 P8C (Lat: 41.723267,  Lng: -87.604489),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 9,150 (year 2021),  Truck Traffic: 7%,  Features Intersected: COTTAGE GROVE,  Facility Carried by Structure: IHB RR
Minimum Vertical Clearance: 4.17m (13.68ft),  Kilometerpoint: 12.021,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 160835,  Location: 0.05 M W I90 P2C (Lat: 41.967900,  Lng: -87.757039),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 14,900 (year 2018),  Truck Traffic: 8%,  Features Intersected: LAWRENCE AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 1.690,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 12.2m (40.0ft)

Find on map >>   Show street view

Structure Number: 160836,  Location: 0.6 M NW IL 50 (Lat: 41.967939,  Lng: -87.756239),  Route carried "under" structure: Interstate 90,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 122,400 (year 2021),  Truck Traffic: 4%,  Features Intersected: I- 90 JFK & CTA,  Facility Carried by Structure: LAWRENCE AVE
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 135.487,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.1m (131.6ft)

Find on map >>   Show street view

Structure Number: 160837,  Location: 0.1 M W ILL 50 P2C (Lat: 41.968000,  Lng: -87.750422),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 20,700 (year 2021),  Truck Traffic: 4%,  Features Intersected: LAWRENCE AVE,  Facility Carried by Structure: SOO (AMTK) RR
Minimum Vertical Clearance: 4.14m (13.58ft),  Kilometerpoint: 2.253,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Slab,  Length of Maximum Span: 7.9m (25.9ft)

Find on map >>   Show street view

Structure Number: 160838,  Location: 0.01 M W ILL 50 P2 (Lat: 41.968014,  Lng: -87.748122),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 20,700 (year 2021),  Truck Traffic: 4%,  Features Intersected: LAWRENCE AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.04m (13.25ft),  Kilometerpoint: 2.446,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 10.7m (35.1ft)

Find on map >>   Show street view

Structure Number: 160839,  Location: 0.3 M N I-94 (Lat: 41.968028,  Lng: -87.747181),  Route carried "under" structure: Interstate 94,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 130,700 (year 2021),  Truck Traffic: 6%,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: LAWRENCE AVE
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 69.200,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.1m (56.1ft)

Find on map >>   Show street view

Structure Number: 160841,  Location: 1.37 M W US 41 P3C (Lat: 41.968822,  Lng: -87.674411),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2018),  Truck Traffic: 4%,  Features Intersected: LAWRENCE AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.32m (14.17ft),  Kilometerpoint: 8.578,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 13.1m (43.0ft)

Find on map >>   Show street view

Structure Number: 160842,  Location: 0.54 M W ILL 41 P3C (Lat: 41.969050,  Lng: -87.658556),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 12,100 (year 2018),  Truck Traffic: 8%,  Features Intersected: LAWRENCE AVE,  Facility Carried by Structure: CTA
Minimum Vertical Clearance: 3.58m (11.75ft),  Kilometerpoint: 9.881,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 160843,  Location: 0.53 M W US 41 P3C (Lat: 41.969053,  Lng: -87.658378),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 12,100 (year 2018),  Truck Traffic: 8%,  Features Intersected: LAWRENCE AVE,  Facility Carried by Structure: CTA
Minimum Vertical Clearance: 3.51m (11.52ft),  Kilometerpoint: 9.897,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 12.5m (41.0ft)

Find on map >>   Show street view

Structure Number: 16085,  Location: 0.18 M W I90 P2C (Lat: 41.960736,  Lng: -87.746886),  Route carried "under" structure: Other road ,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 11,300 (year 2021),  Truck Traffic: 4%,  Features Intersected: MONTROSE AVE.,  Facility Carried by Structure: SOO (AMTK) RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 5.085,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 7.9m (25.9ft)

Find on map >>   Show street view

Structure Number: 160851,  Location: 0.07 M W I90 P2C (Lat: 41.960758,  Lng: -87.744522),  Route carried "under" structure: Other road ,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 11,300 (year 2021),  Truck Traffic: 4%,  Features Intersected: MONTROSE AVE,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 5.262,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 160852,  Location: 5.4 M NW IL 64 (Lat: 41.960767,  Lng: -87.743606),  Route carried "under" structure: Interstate 94,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 110,100 (year 2021),  Truck Traffic: 11%,  Features Intersected: I- 90,94 JFK,  Facility Carried by Structure: MONTROSE AVE
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 70.053,  Lanes on structure: 5,  Lanes under structure: 12,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 49.4m (162.1ft)

Find on map >>   Show street view

Structure Number: 160856,  Location: 0.95 M W I94 P2C (Lat: 41.924781,  Lng: -87.701281),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 21,100 (year 2018),  Truck Traffic: 6%,  Features Intersected: FULLERTON AVE,  Facility Carried by Structure: CTA
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 18.249,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 160857,  Location: 0.25 M E ILL 50 P2C (Lat: 41.924286,  Lng: -87.741606),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 24,800 (year 2018),  Truck Traffic: 5%,  Features Intersected: FULLERTON AVE,  Facility Carried by Structure: CNW RR
Minimum Vertical Clearance: 4.22m (13.85ft),  Kilometerpoint: 14.934,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 16086,  Location: 1.5 M E I94 P3C (Lat: 41.925392,  Lng: -87.652850),  Route carried "under" structure: Other road ,  Year Built: 1951,  Structure Length: 0. m,  Average Daily Traffic: 14,200 (year 2018),  Truck Traffic: 8%,  Features Intersected: FULLERTON AVE,  Facility Carried by Structure: CTA ELEVATED
Minimum Vertical Clearance: 4.17m (13.68ft),  Kilometerpoint: 22.273,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 12.5m (41.0ft)

Find on map >>   Show street view

Structure Number: 160861,  Location: 1.8 M E ILL 50 P4C (Lat: 41.899161,  Lng: -87.710281),  Route carried "under" structure: City street ,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 6,450 (year 2018),  Truck Traffic: 14%,  Features Intersected: AUGUSTA BLVD,  Facility Carried by Structure: CMSTP&P RR
Minimum Vertical Clearance: 4.14m (13.58ft),  Kilometerpoint: 4.876,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 160862,  Location: 0.2 M E I90&94 P5C (Lat: 41.893350,  Lng: -87.647650),  Route carried "under" structure: Other road ,  Year Built: 1936,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2018),  Truck Traffic: 15%,  Features Intersected: HALSTED & ERIE STS,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 6.646,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 10.7m (35.1ft)

Find on map >>   Show street view

Structure Number: 160862,  Location: 0.2 M E I90&94 P5C (Lat: 41.893350,  Lng: -87.647650),  Route carried "under" structure: Other road ,  Year Built: 1936,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 1978),  Features Intersected: HALSTED & ERIE STS,  Facility Carried by Structure: C&NW RR
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 0.370,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 10.7m (35.1ft)

Find on map >>   Show street view

Structure Number: 160872,  Location: 0.5 M E IL 50 (Lat: 41.836761,  Lng: -87.736547),  Route carried "under" structure: City street ,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 850 (year 2018),  Truck Traffic: 11%,  Features Intersected: KILBOURN AVE,  Facility Carried by Structure: 31ST ST
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.3m (66.6ft)

Find on map >>   Show street view

Structure Number: 160875,  Location: 0.21 M E ILL 50 P6C (Lat: 41.807681,  Lng: -87.738256),  Route carried "under" structure: Other road ,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 17,400 (year 2021),  Truck Traffic: 6%,  Features Intersected: 47TH ST,  Facility Carried by Structure: BELT LINE RR
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 0.402,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 160885,  Location: 2 M E ILL 50 P6C (Lat: 41.749717,  Lng: -87.702083),  Route carried "under" structure: Other road ,  Year Built: 1939,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2021),  Truck Traffic: 15%,  Features Intersected: 79TH ST & KEDZIE AVE,  Facility Carried by Structure: N&W RR
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 11.732,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 160886,  Location: 3.3 M E ILL 50 P7C (Lat: 41.750175,  Lng: -87.678094),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2021),  Truck Traffic: 15%,  Features Intersected: 79TH ST,  Facility Carried by Structure: PC RR
Minimum Vertical Clearance: 3.96m (12.99ft),  Kilometerpoint: 13.727,  Lanes under structure: 4,  Material/Design: Concrete,  Length of Maximum Span: 7.9m (25.9ft)

Find on map >>   Show street view

Structure Number: 160887,  Location: 0.05 M E I90 P7C (Lat: 41.756878,  Lng: -87.593792),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 8,950 (year 2021),  Truck Traffic: 2%,  Features Intersected: 76TH ST,  Facility Carried by Structure: PC RR
Minimum Vertical Clearance: 3.89m (12.76ft),  Kilometerpoint: 6.646,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160888,  Location: 0.6 M W I94 P7C (Lat: 41.756147,  Lng: -87.639564),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2021),  Truck Traffic: 2%,  Features Intersected: 76TH ST,  Facility Carried by Structure: CRI&P RR (E)
Minimum Vertical Clearance: 3.66m (12.01ft),  Kilometerpoint: 2.800,  Lanes under structure: 2,  Material/Design: Concrete,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160889,  Location: 0.7 M W I94 P7C (Lat: 41.756206,  Lng: -87.637250),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2021),  Truck Traffic: 2%,  Features Intersected: 76TH ST,  Facility Carried by Structure: CW RR
Minimum Vertical Clearance: 3.68m (12.07ft),  Kilometerpoint: 2.993,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 6.1m (20.0ft)

Find on map >>   Show street view

Structure Number: 160891,  Location: 0.04 M E I90 P7C (Lat: 41.756856,  Lng: -87.595903),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 8,950 (year 2021),  Truck Traffic: 2%,  Features Intersected: 76TH ST,  Facility Carried by Structure: IC RR SPUR
Minimum Vertical Clearance: 3.66m (12.01ft),  Kilometerpoint: 6.502,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160892,  Location: UNDER SKYWAY P7C (Lat: 41.756858,  Lng: -87.595764),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 8,950 (year 2021),  Truck Traffic: 2%,  Features Intersected: 76TH ST,  Facility Carried by Structure: IC RR
Minimum Vertical Clearance: 3.66m (12.01ft),  Kilometerpoint: 6.518,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160893,  Location: .45M W of I94 (Lat: 41.735906,  Lng: -87.633442),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 29,700 (year 2018),  Truck Traffic: 5%,  Features Intersected: 87TH ST,  Facility Carried by Structure: IC RR (WEST)
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 8.948,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160894,  Location: 1.6M W of I94 (Lat: 41.736722,  Lng: -87.600428),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 9%,  Features Intersected: 87TH ST,  Facility Carried by Structure: IC RR (WEST)
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 2.044,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160895,  Location: 1.3M W of I94 (Lat: 41.736783,  Lng: -87.595319),  Route carried "under" structure: Other road ,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 9%,  Features Intersected: 87TH ST,  Facility Carried by Structure: CWI RR
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 2.446,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Length of Maximum Span: 7.6m (24.9ft)

Find on map >>   Show street view

Structure Number: 160896,  Location: 0.03 M E I90 P7C,8 (Lat: 41.737175,  Lng: -87.567447),  Route carried "under" structure: Other road ,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2021),  Truck Traffic: 6%,  Features Intersected: 87TH ST,  Facility Carried by Structure: PC & NYC RR
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 4.764,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160897,  Location: 0.08 M E I90 P7C,8C (Lat: 41.737181,  Lng: -87.567006),  Route carried "under" structure: Other road ,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2021),  Truck Traffic: 6%,  Features Intersected: 87TH ST,  Facility Carried by Structure: NYC RR
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 4.796,  Lanes under structure: 4,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 1609,  Location: 0.1 M N US 12&20 P8C (Lat: 41.723869,  Lng: -87.575394),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 11,300 (year 2021),  Truck Traffic: 5%,  Features Intersected: JEFFERY BLVD,  Facility Carried by Structure: CRI&P RR
Minimum Vertical Clearance: 3.71m (12.17ft),  Kilometerpoint: 5.793,  Lanes under structure: 4,  Material/Design: Concrete,  Length of Maximum Span: 6.7m (22.0ft)

Find on map >>   Show street view

Structure Number: 160932,  Location: 0.1 M S 130TH P8C (Lat: 41.657394,  Lng: -87.559308),  Route carried "under" structure: Other road ,  Year Built: 1936,  Structure Length: 0. m,  Average Daily Traffic: 17,200 (year 2018),  Truck Traffic: 19%,  Features Intersected: TORRENCE AV,  Facility Carried by Structure: N&W RR
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 7.210,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 160944,  Location: 0.49 M S 95TH P8C (Lat: 41.715692,  Lng: -87.536453),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 3,350 (year 2018),  Truck Traffic: 2%,  Features Intersected: AVE "L",  Facility Carried by Structure: BO&C RR
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 0.805,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160945,  Location: 0.52 M S 95TH P8C (Lat: 41.715403,  Lng: -87.536461),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 3,350 (year 2018),  Truck Traffic: 2%,  Features Intersected: AVE "L",  Facility Carried by Structure: PC RR
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 0.837,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160946,  Location: 0.56 M S 95TH P8C (Lat: 41.714819,  Lng: -87.536478),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 3,350 (year 2018),  Truck Traffic: 2%,  Features Intersected: AVE "L",  Facility Carried by Structure: NYC RR (NORTH)
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 0.901,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160947,  Location: 0.58 M S 95TH P8C (Lat: 41.714531,  Lng: -87.536489),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 3,350 (year 2018),  Truck Traffic: 2%,  Features Intersected: AVE "L",  Facility Carried by Structure: NYC RR (SOUTH)
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 0.933,  Lanes under structure: 2,  Material/Design: Steel,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 160968,  Location: 0.9 M SW I-94 (Lat: 41.842133,  Lng: -87.659992),  Route carried "under" structure: City street ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 550 (year 2018),  Truck Traffic: 16%,  Features Intersected: LOOMIS & FULLER STS,  Facility Carried by Structure: I- 55 WB STEVENSON
Minimum Vertical Clearance: 6.22m (20.41ft),  Kilometerpoint: 0.306,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 160968,  Location: 0.9 M SW I-94 (Lat: 41.842531,  Lng: -87.658269),  Route carried "under" structure: Other road ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 9,900 (year 2018),  Truck Traffic: 5%,  Features Intersected: LOOMIS & FULLER STS,  Facility Carried by Structure: I- 55 WB STEVENSON
Minimum Vertical Clearance: 6.05m (19.85ft),  Kilometerpoint: 2.414,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 160969,  Location: 0.2 M S US 12 P8C (Lat: 41.720753,  Lng: -87.585125),  Route carried "under" structure: Other road ,  Year Built: 1936,  Structure Length: 0. m,  Average Daily Traffic: 51,100 (year 2021),  Truck Traffic: 4%,  Features Intersected: STONY ISLAND AVE,  Facility Carried by Structure: C&WI RR
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 83.281,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 29.9m (98.1ft)

Find on map >>   Show street view

Structure Number: 160988,  Location: 2.3 M SW IL 1 (Lat: 41.689281,  Lng: -87.661211),  Route carried "under" structure: Interstate 57,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 111,500 (year 2021),  Truck Traffic: 6%,  Features Intersected: I- 57,  Facility Carried by Structure: 112TH (MONTEREY AV
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 571.382,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.3m (86.3ft)

Find on map >>   Show street view

Structure Number: 160989,  Location: 2 M SW IL 1 (Lat: 41.692150,  Lng: -87.660169),  Route carried "under" structure: Interstate 57,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 111,500 (year 2021),  Truck Traffic: 6%,  Features Intersected: I- 57,  Facility Carried by Structure: 111TH ST
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 571.704,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 160992,  Location: 3.1 M SE I-57 (Lat: 41.692369,  Lng: -87.598292),  Route carried "under" structure: Interstate 94,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 132,400 (year 2021),  Truck Traffic: 8%,  Features Intersected: I- 94 BISHOP FORD,  Facility Carried by Structure: 111TH ST
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 106.503,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.9m (55.4ft)

Find on map >>   Show street view

Structure Number: 161007,  Location: 0.2 M W STATE ST (Lat: 41.777072,  Lng: -87.630069),  Route carried "under" structure: Interstate 90,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 289,600 (year 2021),  Truck Traffic: 6%,  Features Intersected: I- 90,94 RYAN,  Facility Carried by Structure: WENTWORTH AVE
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 161.429,  Lanes on structure: 3,  Lanes under structure: 13,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 53.1m (174.2ft)

Find on map >>   Show street view

Structure Number: 161009,  Location: 1.9 M SW I-90,94 (Lat: 41.837039,  Lng: -87.675736),  Route carried "under" structure: Interstate 55,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 122,100 (year 2021),  Truck Traffic: 10%,  Features Intersected: I- 55 STEVENSON,  Facility Carried by Structure: DAMEN AVE & 4 RAMP
Minimum Vertical Clearance: 7.47m (24.51ft),  Kilometerpoint: 467.807,  Lanes on structure: 6,  Lanes under structure: 9,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.0m (108.3ft)

Find on map >>   Show street view

Structure Number: 161047,  Location: 0.2 M E I-94 (Lat: 41.848661,  Lng: -87.642839),  Route carried "under" structure: Other road ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 18,200 (year 2018),  Truck Traffic: 5%,  Features Intersected: ARCHER; BNSF & IC RR,  Facility Carried by Structure: I- 55 WB RMP RYAN
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 4.844,  Lanes on structure: 1,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 161049,  Location: 0.6 M E I94 (Lat: 41.847361,  Lng: -87.632150),  Route carried "under" structure: Interstate 55,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 79,100 (year 2021),  Truck Traffic: 15%,  Features Intersected: I- 55 STEVENSON,  Facility Carried by Structure: WENTWORTH AVE
Minimum Vertical Clearance: 5.69m (18.67ft),  Kilometerpoint: 471.702,  Lanes on structure: 4,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.7m (74.5ft)

Find on map >>   Show street view

Structure Number: 16105,  Location: 0.1 M W I-94 (Lat: 41.847014,  Lng: -87.642753),  Route carried "under" structure: Interstate 55,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 58,900 (year 2021),  Truck Traffic: 20%,  Features Intersected: I- 55 STEVENSON
Minimum Vertical Clearance: 10.06m (33.01ft),  Kilometerpoint: 470.752,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.3m (96.1ft)

Find on map >>   Show street view

Structure Number: 161053,  Location: 0.6 M E I-94 (Lat: 41.856419,  Lng: -87.642589),  Route carried "under" structure: City street ,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 1,100 (year 2018),  Truck Traffic: 15%,  Features Intersected: KINGSBURY ST,  Facility Carried by Structure: OHIO ST FEEDER E A
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 0.225,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 161056,  Location: 0.6 M E I-94 (Lat: 41.847150,  Lng: -87.630400),  Route carried "under" structure: Interstate 55,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 79,100 (year 2021),  Truck Traffic: 15%,  Features Intersected: I- 55 STEVENSON
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 471.831,  Lanes on structure: 1,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.3m (96.1ft)

Find on map >>   Show street view

Structure Number: 161056,  Location: 0.6 M E I-94 (Lat: 41.846669,  Lng: -87.632111),  Route carried "under" structure: Other road ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 2,350 (year 2018),  Truck Traffic: 7%,  Features Intersected: I- 55 STEVENSON,  Facility Carried by Structure: I- 55 EB TO NB FRK
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.676,  Lanes on structure: 1,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.3m (96.1ft)

Find on map >>   Show street view

Structure Number: 161058,  Location: 2.5 M SW DAN RYAN (Lat: 41.835681,  Lng: -87.684589),  Route carried "under" structure: Other road ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 27,900 (year 2018),  Truck Traffic: 12%,  Features Intersected: WESTERN AVE VIADUCT,  Facility Carried by Structure: I- 55 EB STEVENSON
Minimum Vertical Clearance: 8.84m (29.00ft),  Kilometerpoint: 17.203,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.8m (117.5ft)

Find on map >>   Show street view

Structure Number: 161059,  Location: 0.1 M E I-94 (Lat: 41.847117,  Lng: -87.641925),  Route carried "under" structure: Interstate 55,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 58,900 (year 2021),  Truck Traffic: 20%,  Features Intersected: I- 55 STEVENSON
Minimum Vertical Clearance: 7.92m (25.98ft),  Kilometerpoint: 470.865,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 161062,  Location: 0.1 M W I-94 (Lat: 41.848361,  Lng: -87.643681),  Route carried "under" structure: Other road ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 18,200 (year 2018),  Truck Traffic: 5%,  Features Intersected: ARCHER, BNSF & IC RR,  Facility Carried by Structure: I- 90,94 SB TOI-55
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 4.764,  Lanes on structure: 1,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.0m (65.6ft)

Find on map >>   Show street view

Structure Number: 161064,  Location: 0.1 M S I-55 (Lat: 41.845539,  Lng: -87.631500),  Route carried "under" structure: Other road ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 76,500 (year 2018),  Truck Traffic: 1%,  Features Intersected: FRANKLIN ST EXTEND,  Facility Carried by Structure: 26TH ST
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 2.012,  Lanes on structure: 4,  Lanes under structure: 9,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.0m (82.0ft)

Find on map >>   Show street view

Structure Number: 161066,  Location: 1.5 M SW I-290 (Lat: 41.855347,  Lng: -87.645019),  Route carried "under" structure: Other road ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 5,150 (year 2018),  Truck Traffic: 8%,  Features Intersected: CHI RIV &CANAL P-AVE,  Facility Carried by Structure: I- 90,94 SB TO I55
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.579,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 161067,  Location: 0.6 M S I-55 (Lat: 41.844514,  Lng: -87.631856),  Route carried "under" structure: Other road ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 2,350 (year 2018),  Truck Traffic: 7%,  Features Intersected: STEWART ST TO 29 ST,  Facility Carried by Structure: I- 90,94 ELEV LOCA
Minimum Vertical Clearance: 7.06m (23.16ft),  Kilometerpoint: 0.901,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.0m (111.5ft)

Find on map >>   Show street view

Structure Number: 16107,  Location: 1.4 M SW I-290 (Lat: 41.852661,  Lng: -87.644619),  Route carried "under" structure: Other road ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 8,600 (year 2021),  Truck Traffic: 8%,  Features Intersected: CHI RIVER; CERMAK;RR,  Facility Carried by Structure: I- 55 EB TO I90,94
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 23.013,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 67.1m (220.1ft)

Find on map >>   Show street view

Structure Number: 161071,  Location: 2.7 M NW IL 64 (Lat: 41.936600,  Lng: -87.702639),  Route carried "under" structure: Other road ,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 6,950 (year 2018),  Truck Traffic: 7%,  Features Intersected: SACRAMENTO AVE,  Facility Carried by Structure: I- 90,94 NWB JFK
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 0.660,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 161073,  Location: 2.2 M NW IL 64 (Lat: 41.932122,  Lng: -87.696197),  Route carried "under" structure: Other road ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 16,000 (year 2018),  Truck Traffic: 6%,  Features Intersected: DIVERSEY BLVD,  Facility Carried by Structure: I- 90,94 REV JFK
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 11.506,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 161076,  Location: 2.4 M NW IL 64 (Lat: 41.932992,  Lng: -87.697642),  Route carried "under" structure: Other road ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2018),  Truck Traffic: 7%,  Features Intersected: CALIFORNIA AVE,  Facility Carried by Structure: I- 90,94 REV JFK
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 4.136,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 161077,  Location: 2.4 M NW IL 64 (Lat: 41.933681,  Lng: -87.697661),  Route carried "under" structure: Other road ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2018),  Truck Traffic: 7%,  Features Intersected: CALIFORNIA AVE,  Facility Carried by Structure: I- 90,94 NWB JFK
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 4.088,  Lanes on structure: 6,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 161078,  Location: 2.2 M NW IL 64 (Lat: 41.932119,  Lng: -87.696383),  Route carried "under" structure: Other road ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 16,700 (year 2018),  Truck Traffic: 6%,  Features Intersected: DIVERSEY BLVD,  Facility Carried by Structure: I- 90,94 SEB JFK
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 11.458,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.2m (102.4ft)

Find on map >>   Show street view

Structure Number: 161083,  Location: 2.6 M SW I-90,94 (Lat: 41.838489,  Lng: -87.665756),  Route carried "under" structure: Other road ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 22,300 (year 2021),  Truck Traffic: 9%,  Features Intersected: ASHLAND AVE VIADUCT,  Facility Carried by Structure: I- 55 WB ELEVATED
Minimum Vertical Clearance: 8.74m (28.67ft),  Kilometerpoint: 26.071,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.1m (131.6ft)

Find on map >>   Show street view

Structure Number: 161084,  Location: 2.6 M SW I-90,94 (Lat: 41.838014,  Lng: -87.665733),  Route carried "under" structure: Other road ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 22,300 (year 2021),  Truck Traffic: 9%,  Features Intersected: ASHLAND AVE VIADUCT,  Facility Carried by Structure: I- 55 EB ELEVATED
Minimum Vertical Clearance: 6.71m (22.01ft),  Kilometerpoint: 26.135,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.1m (131.6ft)

Find on map >>   Show street view

Structure Number: 161092,  Location: 0.9 M E I-94 (Lat: 41.847403,  Lng: -87.625833),  Route carried "under" structure: Interstate 55,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 118,500 (year 2021),  Truck Traffic: 10%,  Features Intersected: I- 55 STEVENSON,  Facility Carried by Structure: STATE ST
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 472.153,  Lanes on structure: 5,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.6m (87.3ft)

Discuss Chicago, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.