Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Dickson, Tennessee (TN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 62Number of bridges
  • 358ft / 109mTotal length
  • $12,173,000Total costs
  • 269,648Total average daily traffic
  • 50,052Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Dickson
  • No street view available for this location

New bridges in Dickson, TN - historical statistics
  • New bridges - historical statistics
  • 31920-1929
  • 51930-1939
  • 31940-1949
  • 21950-1959
  • 121960-1969
  • 51970-1979
  • 101980-1989
  • 141990-1999
  • 52000-2009
  • 32010-2019
Reconstructed bridges in Dickson, TN - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
  • 01990-1999
  • 22000-2009
  • 02010-2019
  • 12020-2022
Average Bridge Daily Traffic in Dickson, TN
Average Bridge Truck Traffic in Dickson, TN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 31.8%Very good
  • 36.4%Good
  • 22.7%Satisfactory
  • 9.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 31.8%Very good
  • 31.8%Good
  • 13.6%Satisfactory
  • 18.2%Fair
  • 4.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 40.9%Very good
  • 27.3%Good
  • 9.1%Satisfactory
  • 13.6%Fair
  • 9.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 14.0%Very good
  • 42.0%Good
  • 30.0%Satisfactory
  • 12.0%Fair
  • 2.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 3.0%Very good
  • 69.7%Good
  • 15.2%Satisfactory
  • 9.1%Fair
  • 3.0%Poor
Find on map >>   Show street view

Structure Number: 22S61470005,  Location: 1.5 M. N. I40. (Lat: 36.032883,  Lng: -87.401117),  Route carried "on" structure: County highway 1854,  Year Built: 1970,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 772 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,216 (year 2040),  Features Intersected: EAST FORK PINEY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.143,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.6m (15.1ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Channel: Fair,  Culverts: Poor,  Operating Rating: 42.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.04m (6.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $372,000,  Roadway Improvement Cost: $38,000,  Total Project Cost: $559,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22S61470007,  Location: 2.5 M. N. I40. (Lat: 36.052100,  Lng: -87.397550),  Route carried "on" structure: County highway 1854,  Year Built: 1973,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 772 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,216 (year 2040),  Design Load: H 15,  Features Intersected: EAST FORK PINEY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.332,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.6m (15.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22S62730003,  Location: 5 M. NE. DICKSON (Lat: 36.114000,  Lng: -87.294483),  Route carried "on" structure: County highway 1860,  Year Built: 1978,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 577 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 992 (year 2040),  Design Load: HS 20,  Features Intersected: JONES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.560,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22SR0010001,  Location: 2 MI.E.OF TENN. CITY (Lat: 36.089050,  Lng: -87.472467),  Route carried "on" structure: US 70,  Year Built: 1924,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 8,511 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 13,840 (year 2040),  Design Load: HS 20,  Features Intersected: PINEY CREEK,  Facility Carried by Structure: FAP 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.711,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 22SR0010003,  Location: .3 MI.W. OF DICKSON (Lat: 36.086067,  Lng: -87.408117),  Route carried "on" structure: US 70,  Year Built: 1924,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 11,600 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 21,440 (year 2040),  Design Load: HS 20,  Features Intersected: PINEY CREEK,  Facility Carried by Structure: FAP 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.295,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 22SR0010005,  Location: W. COLLEGE ST.IN DICKSON (Lat: 36.085783,  Lng: -87.401283),  Route carried "on" structure: US 70,  Year Built: 2009,  Status: Open,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 11,600 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 21,440 (year 2040),  Design Load: HL 93,  Features Intersected: CSX RAILROAD,  Facility Carried by Structure: FAP 1 350810G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.004,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.7m (84.3ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.0m (85.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 22SR0010007,  Location: 2.1 MI.E.OF DICKSON (Lat: 36.081667,  Lng: -87.346750),  Route carried "on" structure: US 70,  Year Built: 1939,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 10,456 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 26,128 (year 2040),  Design Load: HS 20,  Features Intersected: BRANCH,  Facility Carried by Structure: FAP 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.580,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.73m (2.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $223,000,  Roadway Improvement Cost: $23,000,  Total Project Cost: $335,000 ( Estimate for 2020)
Find on map >>   Show street view

Structure Number: 22SR0010009,  Location: 3.5 MI.E.OF DICKSON (Lat: 36.087133,  Lng: -87.322300),  Route carried "on" structure: US 70,  Year Built: 1939,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 7,060 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 14,304 (year 2040),  Design Load: HS 20,  Features Intersected: WOLFDEN BRANCH,  Facility Carried by Structure: FAP 1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.857,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 35.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.70m (2.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $180,000,  Roadway Improvement Cost: $19,000,  Total Project Cost: $271,000 ( Estimate for 2020)
Find on map >>   Show street view

Structure Number: 22SR0480003,  Location: 4.3 MI.S.W.OF DICKSON (Lat: 36.027883,  Lng: -87.449917),  Route carried "on" structure: State highway 48,  Year Built: 1992,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 2,624 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,544 (year 2040),  Design Load: HS 20,  Features Intersected: PINEY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.502,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 54.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 22SR0480005,  Location: 3.5 MI.S.W.OF DICKSON (Lat: 36.028550,  Lng: -87.442483),  Route carried "on" structure: State highway 48,  Year Built: 1985,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 2,624 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,544 (year 2040),  Design Load: HS 20,  Features Intersected: BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.194,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.82m (2.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $82,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $124,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22SR0480007,  Location: IN DICKSON CITY LIMITS (Lat: 36.067583,  Lng: -87.398633),  Route carried "on" structure: State highway 48,  Year Built: 1989,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 3,546 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,744 (year 2040),  Design Load: HS 20,  Features Intersected: LITTLE PINEY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.840,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.6m (15.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.16m (3.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $57,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $86,000 ( Estimate for 2020)
Find on map >>   Show street view

Structure Number: 22SR0480009,  Location: 2.7 MI.N.OF DICKSON (Lat: 36.128950,  Lng: -87.359400),  Route carried "on" structure: State highway 48,  Year Built: 1929,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 8,720 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 13,072 (year 2040),  Design Load: HS 20,  Features Intersected: JONES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.968,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.23m (10.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $285,000,  Roadway Improvement Cost: $29,000,  Total Project Cost: $428,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 43017790007,  Location: 2 M. S. SR 1 (Lat: 36.073933,  Lng: -87.439183),  Route carried "on" structure: County highway 1779,  Year Built: 1987,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 165 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 320 (year 2040),  Design Load: HS 20,  Features Intersected: HURRICANE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.859,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 57.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 22031500003,  Location: IN THE CITY OF DICKSON (Lat: 36.076900,  Lng: -87.390967),  Route carried "under" structure: City street 3150,  Year Built: 1930,  Structure Length: 0. m,  Average Daily Traffic: 1,515 (year 2020),  Truck Traffic: 4%,  Features Intersected: CSX RR / SO. CHARLOTTE,  Facility Carried by Structure: CSX RR 348091X
Minimum Vertical Clearance: 2.60m (8.53ft),  Kilometerpoint: 0.161,  Lanes under structure: 1,  Material/Design: Concrete,  Design/Construction: Culvert,  Length of Maximum Span: 4.6m (15.1ft)

Find on map >>   Show street view

Structure Number: 22FA0360001,  Location: NEAR DICKSON TENN. (Lat: 36.081667,  Lng: -87.380000),  Route carried "under" structure: US 70,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 11,429 (year 2020),  Truck Traffic: 9%,  Features Intersected: SR 48 / SR 1,  Facility Carried by Structure: FAU 48
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 14.967,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.9m (127.6ft)

Find on map >>   Show street view

Structure Number: 22I00400005,  Location: 5 M S OF DICKSON (Lat: 36.006950,  Lng: -87.404517),  Route carried "under" structure: County highway 1854,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 772 (year 2020),  Truck Traffic: 3%,  Features Intersected: I40 RL / EAST PINEY RD.,  Facility Carried by Structure: I40
Minimum Vertical Clearance: 3.97m (13.02ft),  Kilometerpoint: 4.216,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 22I00400006,  Location: 5 M S OF DICKSON (Lat: 36.007567,  Lng: -87.404467),  Route carried "under" structure: County highway 1854,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 772 (year 2020),  Truck Traffic: 3%,  Features Intersected: I40 LL / EAST PINEY RD.,  Facility Carried by Structure: I40
Minimum Vertical Clearance: 3.97m (13.02ft),  Kilometerpoint: 4.265,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 22I00400007,  Location: NEAR DICKSON TENN. (Lat: 36.018333,  Lng: -87.338333),  Route carried "under" structure: Interstate 40,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 32,099 (year 2020),  Truck Traffic: 31%,  Features Intersected: CSX RAILROAD / I40,  Facility Carried by Structure: CSX RR 351047N
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 14.581,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.1m (79.1ft)

Find on map >>   Show street view

Structure Number: 22I00400009,  Location: NEAR DICKSON TENN. (Lat: 36.018333,  Lng: -87.336667),  Route carried "under" structure: Interstate 40,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 32,099 (year 2020),  Truck Traffic: 31%,  Features Intersected: SR 46 / I40,  Facility Carried by Structure: FAP 46
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 14.629,  Lanes on structure: 6,  Lanes under structure: 5,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 25.3m (83.0ft)

Find on map >>   Show street view

Structure Number: 22SR0460003,  Location: DICKSON (Lat: 36.070533,  Lng: -87.380317),  Route carried "under" structure: State highway 46,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 27,245 (year 2020),  Truck Traffic: 9%,  Features Intersected: CSX RAILROAD / SR 46,  Facility Carried by Structure: CSX RR 348084M
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 13.052,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Discuss Dickson, Tennessee (TN) on our hugely popular Tennessee forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.