Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Elgin, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 72Number of bridges
  • 1,119ft / 341mTotal length
  • $8,149,000Total costs
  • 1,546,850Total average daily traffic
  • 205,527Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Elgin
  • No street view available for this location

New bridges in Elgin, IL - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 21900-1909
  • 11910-1919
  • 11920-1929
  • 31930-1939
  • 31940-1949
  • 111950-1959
  • 101960-1969
  • 31970-1979
  • 51980-1989
  • 21990-1999
  • 82000-2009
  • 222010-2019
Reconstructed bridges in Elgin, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 41980-1989
  • 11990-1999
  • 32000-2009
Average Bridge Daily Traffic in Elgin, IL
Average Bridge Truck Traffic in Elgin, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 24.4%Very good
  • 17.8%Good
  • 20.0%Satisfactory
  • 22.2%Fair
  • 11.1%Poor
  • 4.4%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.4%Very good
  • 19.1%Good
  • 12.8%Satisfactory
  • 31.9%Fair
  • 8.5%Poor
  • 4.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 29.8%Very good
  • 42.6%Good
  • 21.3%Satisfactory
  • 6.4%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 22.6%Very good
  • 35.5%Good
  • 25.8%Satisfactory
  • 12.9%Fair
  • 3.2%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Very good
  • 60.0%Good
  • 20.0%Satisfactory
Find on map >>   Show street view

Structure Number: 456301,  Location: DOWNTOWN ELGIN (Lat: 42.041528,  Lng: -88.290239),  Route carried "on" structure: Other road ,  Year Built: 1917,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 13.62m (44.69ft),  Average Daily Traffic: 20,000 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 29,986 (year 2032),  Design Load: HS 20,  Features Intersected: FOX RIVER,  Facility Carried by Structure: KIMBALL-ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.835,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 11,  Number Of Approach Spans: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Fair,  Channel: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2020,  Underwater Inspection Date: September 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 456302,  Location: .2MI S BIG TIMBER RD (Lat: 42.089286,  Lng: -88.401411),  Route carried "on" structure: Other road ,  Year Built: 2010,  Status: Open,  Structure Length: 2.30m (7.55ft),  Average Daily Traffic: 2,300 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,340 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: TYLER CREEK,  Facility Carried by Structure: DAMISCH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 456304,  Location: 0.7 MI. N US-20 (Lat: 42.029533,  Lng: -88.279633),  Route carried "on" structure: Other road ,  Year Built: 1949,  Status: Open,  Structure Length: 8.41m (27.59ft),  Average Daily Traffic: 6,700 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 11,356 (year 2032),  Features Intersected: FOX RIVER,  Facility Carried by Structure: NATIONAL STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.738,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.9m (78.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2020,  Underwater Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 456305,  Location: .3 MI W MCLEAN BLVD (Lat: 42.046547,  Lng: -88.314825),  Route carried "on" structure: City street ,  Year Built: 1967,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 75 (year 2018),  Truck Traffic: 11%,  Average Future Daily Traffic: 251 (year 2019),  Design Load: H 15,  Features Intersected: TYLER CREEK,  Facility Carried by Structure: EAGLE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.3m (20.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 456306,  Location: .4 MI W MCLEAN BLVD (Lat: 42.051928,  Lng: -88.323286),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 5,750 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,200 (year 2032),  Design Load: HS 20,  Features Intersected: TYLER CREEK,  Facility Carried by Structure: ROYAL BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.432,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 456307,  Location: E BANK FOX RIVER (Lat: 42.037664,  Lng: -88.285667),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 7.06m (23.16ft),  Average Daily Traffic: 850 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 267 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: PARKING GARAGE,  Facility Carried by Structure: RIVERSIDE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 456312,  Location: 0.14 MI SW OF CH34 (Lat: 42.024483,  Lng: -88.340950),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 3,800 (year 2019),  Average Future Daily Traffic: 5,738 (year 2038),  Design Load: HS 20,  Features Intersected: OTTER CREEK,  Facility Carried by Structure: SOUTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.754,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.8m (15.7ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 88.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 76.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 459909,  Location: I90 2.5M W ILL 31 (Lat: 42.080622,  Lng: -88.335550),  Route carried "on" structure: Other road ,  Year Built: 1958,  Status: Open,  Structure Length: 7.49m (24.57ft),  Average Daily Traffic: 41,800 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 55,378 (year 2032),  Design Load: HS 20,  Features Intersected: INTERSTATE 90,  Facility Carried by Structure: RANDALL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.079,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: County Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.4m (76.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45997,  Location: .25 MI E RANDALL RD (Lat: 42.072628,  Lng: -88.317275),  Route carried "on" structure: Interstate 90,  Year Built: 2014,  Status: Open,  Structure Length: 2.59m (8.50ft),  Average Daily Traffic: 43,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 57,548 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SLEEPY HOLLOW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.663,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 23.8m (78.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 24.7m (81.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Other
Find on map >>   Show street view

Structure Number: 459971,  Location: .25 M E RANDALL RD (Lat: 42.072569,  Lng: -88.317108),  Route carried "on" structure: Interstate 90,  Year Built: 2014,  Status: Open,  Structure Length: 2.60m (8.53ft),  Average Daily Traffic: 43,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 57,548 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SLEEPY HOLLOW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.679,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 23.8m (78.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 24.7m (81.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Other
Find on map >>   Show street view

Structure Number: 459992,  Location: 1.5 Mi. W. of IL 25 (Lat: 42.067236,  Lng: -88.291831),  Route carried "on" structure: Interstate 90,  Year Built: 2015,  Status: Open,  Structure Length: 3.94m (12.93ft),  Average Daily Traffic: 43,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 57,548 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Ill. Rte. 31
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 87.884,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 27.1m (88.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.3m (125.7ft),  Curb-To-Curb Width: 27.1m (88.9ft),  Out-to-Out Width: 28.2m (92.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 459993,  Location: 1.5 Mi W. of Il 25 (Lat: 42.067236,  Lng: -88.291831),  Route carried "on" structure: Interstate 90,  Year Built: 2016,  Status: Open,  Structure Length: 3.94m (12.93ft),  Average Daily Traffic: 43,000 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 57,548 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Illinois Route 31
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 87.884,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 27.1m (88.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.3m (125.7ft),  Curb-To-Curb Width: 27.1m (88.9ft),  Out-to-Out Width: 28.2m (92.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 82.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 56.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 459994,  Location: 1 Mi. E. Ill. 31 (Lat: 42.066381,  Lng: -88.273214),  Route carried "on" structure: Interstate 90,  Year Built: 2015,  Status: Open,  Structure Length: 40.10m (131.56ft),  Average Daily Traffic: 50,350 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 68,968 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Fox River/Duncan Ave
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 89.348,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 51.8m (169.9ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 25.4m (83.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2019,  Underwater Inspection Date: April 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 459995,  Location: 1 Mi. E. of IL 31 (Lat: 42.066389,  Lng: -88.269683),  Route carried "on" structure: Interstate 90,  Year Built: 2015,  Status: Open,  Structure Length: 40.10m (131.56ft),  Average Daily Traffic: 50,350 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 68,968 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Fox River/Duncan Ave
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 89.574,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 0.0m,  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 25.4m (83.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2019,  Underwater Inspection Date: April 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160218,  Location: 1 M E KANE CO (Lat: 42.021367,  Lng: -88.247250),  Route carried "under" structure: Other road ,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 5,750 (year 2018),  Truck Traffic: 7%,  Features Intersected: US 20 VILLA ST,  Facility Carried by Structure: US 20 WB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 1.609,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 169057,  Location: 0.25 Mi E. of Il. 25 (Lat: 42.066378,  Lng: -88.258392),  Route carried "under" structure: Interstate 90,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 101,700 (year 2020),  Truck Traffic: 26%,  Features Intersected: I-90,  Facility Carried by Structure: Ill. Rte. 25 Ramp
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 90.700,  Lanes on structure: 2,  Lanes under structure: 9,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.8m (137.1ft)

Find on map >>   Show street view

Structure Number: 450005,  Location: 0.25 M W OF IL 25 (Lat: 42.020150,  Lng: -88.272419),  Route carried "under" structure: Other road ,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 4,850 (year 2018),  Truck Traffic: 5%,  Features Intersected: RAYMOND ST,  Facility Carried by Structure: US 20
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 2.977,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 450006,  Location: 1 BLOCK W OF IL 25 (Lat: 42.020272,  Lng: -88.268519),  Route carried "under" structure: City street ,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 3,250 (year 2018),  Truck Traffic: 22%,  Features Intersected: ST CHARLES ST,  Facility Carried by Structure: US 20
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.080,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 450007,  Location: US 20 & LIBERTY ST (Lat: 42.020211,  Lng: -88.267331),  Route carried "under" structure: State highway 25,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 14,900 (year 2021),  Truck Traffic: 15%,  Features Intersected: IL 25 (LIBERTY ST),  Facility Carried by Structure: US 20
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 41.858,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 450008,  Location: 2.6 M W OF IL 31 (Lat: 42.031478,  Lng: -88.336236),  Route carried "under" structure: US 20,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,700 (year 2021),  Truck Traffic: 14%,  Features Intersected: US 20 WB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 228.118,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 450017,  Location: 3 M S OF I-90 (Lat: 42.021903,  Lng: -88.283469),  Route carried "under" structure: US 20,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 38,100 (year 2021),  Truck Traffic: 16%,  Features Intersected: US 20 BY PASS,  Facility Carried by Structure: IL 31
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 232.544,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.5m (67.3ft)

Find on map >>   Show street view

Structure Number: 45006,  Location: 2.5 M W OF IL 31 (Lat: 42.032325,  Lng: -88.338861),  Route carried "under" structure: US 20,  Year Built: 1961,  Structure Length: 0. m,  Average Daily Traffic: 28,000 (year 2021),  Truck Traffic: 9%,  Features Intersected: US 20 BY PASS,  Facility Carried by Structure: RANDALL RD
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 227.796,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 450066,  Location: 0.1 M W OF ILL 31 (Lat: 42.036792,  Lng: -88.288978),  Route carried "under" structure: Other road ,  Year Built: 1893,  Structure Length: 0. m,  Average Daily Traffic: 9,150 (year 2018),  Truck Traffic: 5%,  Features Intersected: US 20B (HIGHLAND A),  Facility Carried by Structure: CHGO & NW RR
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 4.072,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 450077,  Location: 1.3 M W OF IL 31 (Lat: 42.023350,  Lng: -88.312081),  Route carried "under" structure: Other road ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 25,300 (year 2018),  Truck Traffic: 5%,  Features Intersected: MCLEAN BLVD,  Facility Carried by Structure: US 20
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 9.125,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 76.2m (250.0ft)

Find on map >>   Show street view

Structure Number: 450111,  Location: 1.5 M E of IL 31 (Lat: 42.066397,  Lng: -88.263392),  Route carried "under" structure: Interstate 90,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 100,700 (year 2021),  Truck Traffic: 26%,  Features Intersected: I- 90 ADAMS TOLL,  Facility Carried by Structure: IL 25
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 90.298,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>   Show street view

Structure Number: 459007,  Location: 0.85 Mi W of Ill 31 (Lat: 42.070103,  Lng: -88.306697),  Route carried "under" structure: Interstate 90,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2020),  Truck Traffic: 16%,  Features Intersected: I-90,  Facility Carried by Structure: Pedestrian Walkway
Minimum Vertical Clearance: 7.32m (24.02ft),  Kilometerpoint: 86.613,  Lanes under structure: 16,  Toll: On toll road,  Material/Design: Steel continuous,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>   Show street view

Structure Number: 459909,  Location: I90 2.5M W ILL 31 (Lat: 42.080622,  Lng: -88.335550),  Route carried "under" structure: Interstate 90,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 86,000 (year 2020),  Truck Traffic: 16%,  Features Intersected: INTERSTATE 90,  Facility Carried by Structure: RANDALL ROAD
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 83.973,  Lanes on structure: 4,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 45994,  Location: 4.2 M W OF ILL 31 (Lat: 42.002469,  Lng: -88.370089),  Route carried "under" structure: County highway ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 3,350 (year 2018),  Truck Traffic: 4%,  Features Intersected: NOLAN ROAD,  Facility Carried by Structure: ILL CENTRAL GULF R
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.451,  Lanes under structure: 2,  Material/Design: Wood or Timber,  Length of Maximum Span: 10.7m (35.1ft)

Find on map >>   Show street view

Structure Number: 45997,  Location: .25 MI E RANDALL RD (Lat: 42.072378,  Lng: -88.316939),  Route carried "under" structure: Other road ,  Year Built: 2014,  Structure Length: 0. m,  Average Daily Traffic: 6,900 (year 2018),  Truck Traffic: 3%,  Features Intersected: SLEEPY HOLLOW RD,  Facility Carried by Structure: I-90
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 3.508,  Lanes on structure: 4,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.1m (79.1ft)

Find on map >>   Show street view

Structure Number: 459971,  Location: .25 M E RANDALL RD (Lat: 42.072747,  Lng: -88.316914),  Route carried "under" structure: Other road ,  Year Built: 2014,  Structure Length: 0. m,  Average Daily Traffic: 6,900 (year 2018),  Truck Traffic: 3%,  Features Intersected: SLEEPY HOLLOW RD,  Facility Carried by Structure: I-90
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 3.476,  Lanes on structure: 4,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.1m (79.1ft)

Find on map >>   Show street view

Structure Number: 459992,  Location: 1.5 Mi. W. of IL 25 (Lat: 42.067389,  Lng: -88.291494),  Route carried "under" structure: State highway 31,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 22,400 (year 2021),  Truck Traffic: 8%,  Features Intersected: Ill. Rte. 31,  Facility Carried by Structure: I-90 (WB)
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 47.555,  Lanes on structure: 4,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.3m (125.7ft)

Find on map >>   Show street view

Structure Number: 459993,  Location: 1.5 Mi W. of Il 25 (Lat: 42.067158,  Lng: -88.291533),  Route carried "under" structure: State highway 31,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2021),  Truck Traffic: 11%,  Features Intersected: Illinois Route 31,  Facility Carried by Structure: I-90 (EB)
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 47.539,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.3m (125.7ft)

Find on map >>   Show street view

Structure Number: 459994,  Location: 1 Mi. E. Ill. 31 (Lat: 42.066558,  Lng: -88.269414),  Route carried "under" structure: Other road ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 2,050 (year 2018),  Truck Traffic: 5%,  Features Intersected: Fox River/Duncan Ave,  Facility Carried by Structure: I-90 (EB)
Minimum Vertical Clearance: 10.67m (35.01ft),  Kilometerpoint: 5.649,  Lanes on structure: 4,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 459995,  Location: 1 Mi. E. of IL 31 (Lat: 42.066389,  Lng: -88.269439),  Route carried "under" structure: Other road ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 2,050 (year 2018),  Truck Traffic: 5%,  Features Intersected: Fox River/Duncan Ave,  Facility Carried by Structure: I-90 (WB)
Minimum Vertical Clearance: 10.67m (35.01ft),  Kilometerpoint: 5.665,  Lanes on structure: 4,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 0.0m

Discuss Elgin, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.