Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for New Haven, Connecticut (CT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 179Number of bridges
  • 3,461ft / 1,055mTotal length
  • $136,065,000Total costs
  • 5,621,098Total average daily traffic
  • 529,194Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for New Haven
  • No street view available for this location

New bridges in New Haven, CT - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 91900-1909
  • 61910-1919
  • 41920-1929
  • 31930-1939
  • 91940-1949
  • 131950-1959
  • 611960-1969
  • 31970-1979
  • 81980-1989
  • 61990-1999
  • 162000-2009
  • 402010-2019
Reconstructed bridges in New Haven, CT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31960-1969
  • 11970-1979
  • 121980-1989
  • 71990-1999
  • 102000-2009
  • 82010-2019
Average Bridge Daily Traffic in New Haven, CT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.7%Very good
  • 54.7%Good
  • 34.0%Satisfactory
  • 5.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 4.4%Very good
  • 37.7%Good
  • 42.1%Satisfactory
  • 14.9%Fair
  • 0.9%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.8%Very good
  • 45.6%Good
  • 39.5%Satisfactory
  • 11.4%Fair
  • 1.8%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.7%Very good
  • 20.9%Good
  • 55.8%Satisfactory
  • 14.0%Fair
  • 4.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 22.2%Good
  • 33.3%Satisfactory
  • 44.4%Fair
Find on map >>   Show street view

Structure Number: 16,  Location: .7 MI EAST OF MIANUS RV (Lat: 41.038622,  Lng: -73.586811),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 5.58m (18.31ft),  Average Daily Traffic: 9,500 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,116 (year 2031),  Design Load: HS 20,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: RIVERSIDE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.0m (88.6ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 157,  Location: I-95 AT EXIT 42 (Lat: 41.273269,  Lng: -72.970250),  Route carried "on" structure: Interstate 95,  Year Built: 2005,  Status: Open,  Structure Length: 4.92m (16.14ft),  Average Daily Traffic: 105,200 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 156,317 (year 2041),  Design Load: HS 20,  Features Intersected: ROUTE 162
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 70.666,  Lanes on structure: 7,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 38.7m (127.0ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.2m (151.6ft),  Curb-To-Curb Width: 38.8m (127.3ft),  Out-to-Out Width: 41.7m (136.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 158,  Location: 0.2 MI N OF ROUTE 162 (Lat: 41.275922,  Lng: -72.968303),  Route carried "on" structure: Interstate 95,  Year Built: 1957,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 114,100 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 169,541 (year 2040),  Design Load: H 20,  Features Intersected: GRETA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 71.036,  Lanes on structure: 7,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 40.8m (133.9ft),  Out-to-Out Width: 42.6m (139.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 159,  Location: 0.7 MI N OF ROUTE 162 (Lat: 41.279417,  Lng: -72.961111),  Route carried "on" structure: City street ,  Year Built: 1957,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 3.78m (12.40ft),  Average Daily Traffic: 4,634 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,886 (year 2041),  Design Load: HS 20,  Features Intersected: INTERSTATE 95,  Facility Carried by Structure: STEVENS AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.322,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 14.5m (47.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 163A,  Location: 0.5 MI S OF RT 10 (Lat: 41.283572,  Lng: -72.939208),  Route carried "on" structure: Interstate 95,  Year Built: 2018,  Status: Open,  Structure Length: 31.47m (103.25ft),  Average Daily Traffic: 137,300 (year 2017),  Truck Traffic: 14%,  Average Future Daily Traffic: 204,014 (year 2037),  Design Load: HL 93,  Features Intersected: WEST RIVER & SR 745
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 73.547,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.6m (77.4ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 62.0m (203.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 23.6m (77.4ft),  Out-to-Out Width: 44.3m (145.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Underwater Inspection Date: June 2018,  Total Project Cost: $47,332,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 164,  Location: 1.5 MILES SOUTH OF I-91 (Lat: 41.283975,  Lng: -72.934553),  Route carried "on" structure: Interstate 95,  Year Built: 1957,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 3.43m (11.25ft),  Average Daily Traffic: 128,000 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 190,195 (year 2037),  Design Load: HL 93,  Features Intersected: ROUTE 10
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 74.110,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 38.4m (126.0ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.1m (105.3ft),  Curb-To-Curb Width: 38.4m (126.0ft),  Out-to-Out Width: 41.3m (135.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Total Project Cost: $47,332,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 165,  Location: 0.2 MI N OF ROUTE 10 (Lat: 41.284633,  Lng: -72.930561),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 4,002 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,947 (year 2041),  Design Load: HL 93,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: HOWARD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.306,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 3.5m (11.5ft),  Right: 3.5m (11.5ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 24.5m (80.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 172,  Location: OVER WATER STREET (Lat: 41.299019,  Lng: -72.915708),  Route carried "on" structure: Interstate 95,  Year Built: 2013,  Status: Open,  Structure Length: 42.18m (138.39ft),  Average Daily Traffic: 61,300 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 91,086 (year 2037),  Design Load: HS 20,  Features Intersected: I-91NB,US1,RTE 34 & RAMP
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 76.798,  Lanes on structure: 6,  Lanes under structure: 15,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 36.0m (118.1ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 76.0m (249.3ft),  Curb-To-Curb Width: 36.0m (118.1ft),  Out-to-Out Width: 38.9m (127.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 174A,  Location: OVER QUINNIPIAC RIVER (Lat: 41.301856,  Lng: -72.910983),  Route carried "on" structure: Interstate 95,  Year Built: 2014,  Status: Open,  Structure Length: 141.55m (464.40ft),  Average Daily Traffic: 73,300 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 108,916 (year 2037),  Design Load: HS 20,  Features Intersected: US1,QUINNIPIAC RV,P&W RR
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 76.283,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 9 degrees,  Navigation Control: Yes ( Vertical Clearance: 19.5m (64.0ft), Horizontal Clearance: 70.1m (230.0ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stayed Girder,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 20,  Length of Maximum Span: 157.0m (515.1ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2019,  Underwater Inspection Date: May 2019,  Total Project Cost: $3,000,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 174B,  Location: OVER QUINNIPIAC RIVER (Lat: 41.301933,  Lng: -72.910969),  Route carried "on" structure: Interstate 95,  Year Built: 2015,  Status: Open,  Structure Length: 140.15m (459.81ft),  Average Daily Traffic: 73,300 (year 2017),  Truck Traffic: 9%,  Average Future Daily Traffic: 108,916 (year 2037),  Design Load: HS 20,  Features Intersected: US1,QUINNIPIAC RV,P&W RR
Minimum Vertical Clearance: 6.35m (20.83ft),  Kilometerpoint: 76.927,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 9 degrees,  Navigation Control: Yes ( Vertical Clearance: 18.3m (60.0ft), Horizontal Clearance: 86.3m (283.1ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stayed Girder,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 20,  Length of Maximum Span: 157.0m (515.1ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 55.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 2019,  Underwater Inspection Date: May 2019,  Total Project Cost: $3,000,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 174C,  Location: AT WEST END OF Q-BRIDGE (Lat: 41.300250,  Lng: -72.913278),  Route carried "on" structure: Ramp State highway 34,  Year Built: 2011,  Status: Open,  Structure Length: 44.68m (146.59ft),  Average Daily Traffic: 26,700 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 39,674 (year 2037),  Design Load: HS 20,  Features Intersected: US1, Local Rds, P&W RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.866,  Lanes on structure: 1,  Lanes under structure: 11,  Owner: State Highway Agency,  Approaching Roadway Width: 9.0m (29.5ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 62.5m (205.1ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 174D,  Location: AT WEST END OF Q-BRIDGE (Lat: 41.301361,  Lng: -72.910861),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1958,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 14.78m (48.49ft),  Average Daily Traffic: 20,300 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 30,164 (year 2038),  Design Load: HS 20,  Features Intersected: EAST STREET & PWRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.1m (46.3ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 55.5m (182.1ft),  Curb-To-Curb Width: 14.1m (46.3ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 174E,  Location: AT WEST END OF Q-BRIDGE (Lat: 41.302222,  Lng: -72.910944),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 2016,  Status: Open,  Structure Length: 25.70m (84.32ft),  Average Daily Traffic: 22,310 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 33,150 (year 2035),  Design Load: HS 20,  Features Intersected: EAST STREET & P&W RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 22.7m (74.5ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 60.4m (198.2ft),  Curb-To-Curb Width: 22.7m (74.5ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 179,  Location: 1.7 MI N OF I-91 (Lat: 41.289239,  Lng: -72.892486),  Route carried "on" structure: State highway 337,  Year Built: 2006,  Status: Open,  Structure Length: 5.46m (17.91ft),  Average Daily Traffic: 7,300 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,847 (year 2038),  Design Load: HL 93,  Features Intersected: INTERSTATE-95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 4,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 15.6m (51.2ft),  Out-to-Out Width: 22.4m (73.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 18,  Location: 1.6 MI N OF I-91 (Lat: 41.288750,  Lng: -72.890033),  Route carried "on" structure: US 1,  Year Built: 2006,  Status: Open,  Structure Length: 7.96m (26.12ft),  Average Daily Traffic: 10,650 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,825 (year 2038),  Design Load: HL 93,  Features Intersected: INTERSTATE-95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.014,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.9m (130.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 27.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 208,  Location: 400 FT N. OF US ROUTE 1 (Lat: 41.289311,  Lng: -72.658108),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 5.38m (17.65ft),  Average Daily Traffic: 2,660 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,952 (year 2041),  Design Load: H 20,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: TANNER MARSH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.306,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.1m (85.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 83.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 209,  Location: 2.1 MI NORTH OF ROUTE 77 (Lat: 41.288806,  Lng: -72.648686),  Route carried "on" structure: Interstate 95,  Year Built: 1957,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 69,000 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 102,527 (year 2037),  Design Load: HS 20,  Features Intersected: EAST RIVER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 100.278,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 28.7m (94.2ft),  Skew: 33 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 29.7m (97.4ft),  Out-to-Out Width: 31.6m (103.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 276,  Location: .2 MI N OF ROUTE 2 & 32 (Lat: 41.549139,  Lng: -72.107706),  Route carried "on" structure: Interstate 395,  Year Built: 1958,  Status: Open,  Structure Length: 7.18m (23.56ft),  Average Daily Traffic: 20,300 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 30,164 (year 2040),  Design Load: HS 20,  Features Intersected: YANTIC RIVER, NEC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.370,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.7m (81.0ft),  Curb-To-Curb Width: 29.9m (98.1ft),  Out-to-Out Width: 31.6m (103.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 24.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 18.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Underwater Inspection Date: September 2021,  Total Project Cost: $1,309,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 277,  Location: 0.5 MI N OF ROUTE 2 & 32 (Lat: 41.553475,  Lng: -72.105828),  Route carried "on" structure: Interstate 395,  Year Built: 1958,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 2.66m (8.73ft),  Average Daily Traffic: 36,200 (year 2017),  Truck Traffic: 14%,  Average Future Daily Traffic: 53,790 (year 2037),  Design Load: HS 20,  Features Intersected: SR 642 WEST TOWN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.901,  Lanes on structure: 5,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 22 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 33.6m (110.2ft),  Out-to-Out Width: 34.6m (113.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 278,  Location: 1.6 MILES NORTH OF SR 642 (Lat: 41.571975,  Lng: -72.087925),  Route carried "on" structure: City street ,  Year Built: 1958,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 6.14m (20.14ft),  Average Daily Traffic: 1,600 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,377 (year 2037),  Design Load: H 20,  Features Intersected: INTERSTATE-395,  Facility Carried by Structure: SCOTLAND ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.462,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Galvanized Reinforcing
Find on map >>   Show street view

Structure Number: 337,  Location: 0.2 MI S OF I-95 Q-BRIDGE (Lat: 41.298072,  Lng: -72.905036),  Route carried "on" structure: US 1,  Year Built: 2002,  Status: Open,  Structure Length: 28.53m (93.60ft),  Average Daily Traffic: 12,400 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 18,425 (year 2038),  Design Load: HS 20,  Features Intersected: QUINNIPIAC RIVER
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 79.228,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Navigation Control: Yes ( Vertical Clearance: 4.0m (13.1ft), Horizontal Clearance: 73.2m (240.2ft)),  Material/Design: Steel,  Design/Construction: Movable - Lift,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 6,  Length of Maximum Span: 82.3m (270.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Critical Feature Inspection Date: January 2021,  Underwater Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 77,  Location: 1 MILE WEST OF ROUTE 63 (Lat: 41.330903,  Lng: -72.986214),  Route carried "on" structure: State highway 15,  Year Built: 1948,  Status: Posted for load-capacity,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 71,400 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 106,093 (year 2035),  Design Load: HS 20,  Features Intersected: ROUTE 243
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 73.933,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 771,  Location: 3.7 MI W. OF ROUTE 10 (Lat: 41.337186,  Lng: -72.979075),  Route carried "on" structure: State highway 15,  Year Built: 1948,  Year Reconstructed: 1989,  Status: Posted for load-capacity,  Structure Length: 2.23m (7.32ft),  Average Daily Traffic: 72,300 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 107,431 (year 2039),  Design Load: HS 20,  Features Intersected: ROUTE 63
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 74.851,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 21.1m (69.2ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 83.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 772,  Location: .3MI NO OF RT 63 & 69 INT (Lat: 41.339331,  Lng: -72.976669),  Route carried "on" structure: State highway 15,  Year Built: 1949,  Year Reconstructed: 1987,  Status: Posted for load-capacity,  Structure Length: 7.83m (25.69ft),  Average Daily Traffic: 61,200 (year 2019),  Average Future Daily Traffic: 90,937 (year 2039),  Design Load: HS 20,  Features Intersected: ROUTE 69 & WEST RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 75.172,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 21.7m (71.2ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 774A,  Location: 0.7 MI N OF ROUTE 69 (Lat: 41.346881,  Lng: -72.967939),  Route carried "on" structure: State highway 15,  Year Built: 1949,  Status: Posted for load-capacity,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 39,600 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 58,842 (year 2035),  Features Intersected: WINTERGREEN AVE & BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 76.299,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 774B,  Location: 0.7 MI N OF ROUTE 69 (Lat: 41.347067,  Lng: -72.968053),  Route carried "on" structure: State highway 15,  Year Built: 1949,  Status: Posted for load-capacity,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 39,200 (year 2016),  Truck Traffic: 1%,  Average Future Daily Traffic: 58,247 (year 2036),  Features Intersected: WINTERGREEN AVE & BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 76.315,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 951,  Location: BTWN N & S FRONTAGE ROADS (Lat: 41.302458,  Lng: -72.928483),  Route carried "on" structure: City street ,  Year Built: 1960,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 14,294 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 21,239 (year 2040),  Design Load: HS 20,  Features Intersected: ROUTE 34,  Facility Carried by Structure: CHURCH ST SOUTH #1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.418,  Lanes on structure: 5,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 952,  Location: 0.3 MI E. OF US ROUTE 1 (Lat: 41.300581,  Lng: -72.918306),  Route carried "on" structure: State highway 34,  Year Built: 2011,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 35,900 (year 2016),  Truck Traffic: 8%,  Average Future Daily Traffic: 53,344 (year 2036),  Design Load: HS 20,  Features Intersected: BREWERY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.721,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 953,  Location: 250FT SOUTH OF US 1 (Lat: 41.300022,  Lng: -72.918336),  Route carried "on" structure: State highway 34,  Year Built: 1960,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 37,800 (year 2012),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,167 (year 2032),  Design Load: HS 20,  Features Intersected: BREWERY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.737,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1031,  Location: 105 FT N OF ROUTE 10 (Lat: 41.325172,  Lng: -72.957408),  Route carried "on" structure: State highway 63,  Year Built: 1921,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 23,100 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 34,324 (year 2038),  Features Intersected: WEST RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 27.4m (89.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 175,  Location: 150'N TROUT BROOK DRIVE (Lat: 41.741975,  Lng: -72.734261),  Route carried "on" structure: Ramp Interstate 84,  Year Built: 1965,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 2,800 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 4,161 (year 2038),  Design Load: HS 20,  Features Intersected: TROUT BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.6m (24.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 90.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 69.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 178,  Location: 0.3 MI S OF ROUTE 117 (Lat: 41.361261,  Lng: -72.034325),  Route carried "on" structure: Interstate 95,  Year Built: 1964,  Status: Open,  Structure Length: 3.19m (10.47ft),  Average Daily Traffic: 35,700 (year 2017),  Truck Traffic: 14%,  Average Future Daily Traffic: 53,047 (year 2037),  Design Load: H 20,  Features Intersected: POHEGNUT POND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 156.348,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Inventory Rating: 52.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2166,  Location: 2.8 MI S. OF US ROUTE 1 (Lat: 41.250986,  Lng: -72.889472),  Route carried "on" structure: State highway 337,  Year Built: 1936,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 2,600 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,863 (year 2038),  Design Load: HS 20,  Features Intersected: MORRIS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.538,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Fair,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: March 2021,  Total Project Cost: $1,500,000 ( Estimate for 2017),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 3014A,  Location: 1.4 MI N OF I-95 (Lat: 41.316147,  Lng: -72.905664),  Route carried "on" structure: Interstate 91,  Year Built: 1965,  Status: Open,  Structure Length: 32.80m (107.61ft),  Average Daily Traffic: 67,500 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 100,298 (year 2039),  Design Load: HS 20,  Features Intersected: MILL RV-STATE ST RMP 140
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.173,  Lanes on structure: 5,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 15,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.6m (67.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 3014B,  Location: I-91 NB EXIT NO. 5 (Lat: 41.315647,  Lng: -72.906169),  Route carried "on" structure: Ramp Interstate 91,  Year Built: 1965,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 9,900 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 14,710 (year 2035),  Design Load: HS 20,  Features Intersected: MILL RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Underwater Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 3014C,  Location: I91 NB OFF RAMP TO WILLOW (Lat: 41.316972,  Lng: -72.904506),  Route carried "on" structure: Ramp Interstate 91,  Year Built: 1965,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 4,200 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 6,241 (year 2039),  Design Load: HS 20,  Features Intersected: I-91 NB RAMP 140
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 57.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 3015A,  Location: 1.4 MI N OF I-95 (Lat: 41.316389,  Lng: -72.906389),  Route carried "on" structure: Interstate 91,  Year Built: 1965,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 31.82m (104.40ft),  Average Daily Traffic: 73,100 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 108,619 (year 2035),  Design Load: HS 20,  Features Intersected: STATE ST MILL RIV RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.301,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 11,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 19.6m (64.3ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 36.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Critical Feature Inspection Date: September 2020,  Underwater Inspection Date: September 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3015B,  Location: I91SB ON RAMP FROM WILLOW (Lat: 41.317339,  Lng: -72.905383),  Route carried "on" structure: Ramp Interstate 91,  Year Built: 1965,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 4,750 (year 2016),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,058 (year 2036),  Design Load: HS 20,  Features Intersected: NO NOTABLE FEATURE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Discuss New Haven, Connecticut (CT) on our hugely popular Connecticut forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.