Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Roscoe, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 69Number of bridges
  • 623ft / 190mTotal length
  • $938,000Total costs
  • 848,550Total average daily traffic
  • 179,362Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Roscoe
  • No street view available for this location

New bridges in Roscoe, IL - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11910-1919
  • 11920-1929
  • 181950-1959
  • 211960-1969
  • 111970-1979
  • 51980-1989
  • 21990-1999
  • 82000-2009
  • 12010-2019
Average Bridge Daily Traffic in Roscoe, IL
Average Bridge Truck Traffic in Roscoe, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.4%Very good
  • 27.6%Good
  • 27.6%Satisfactory
  • 37.9%Fair
  • 3.4%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.4%Very good
  • 34.5%Good
  • 20.7%Satisfactory
  • 31.0%Fair
  • 6.9%Poor
  • 3.4%Critical
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 13.8%Very good
  • 31.0%Good
  • 41.4%Satisfactory
  • 13.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 22.2%Very good
  • 15.6%Good
  • 42.2%Satisfactory
  • 20.0%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 10.3%Very good
  • 41.4%Good
  • 34.5%Satisfactory
  • 10.3%Fair
  • 3.4%Poor
Find on map >>   Show street view

Structure Number: 1016602,  Location: .2 MI S OF SWANSON R (Lat: 42.389114,  Lng: -89.013267),  Route carried "on" structure: City street ,  Year Built: 2007,  Status: Open,  Structure Length: 1.75m (5.74ft),  Average Daily Traffic: 1,000 (year 2017),  Average Future Daily Traffic: 350 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: S BR MCDONALD CRK,  Facility Carried by Structure: SWANSON DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 1019901,  Location: 1 MI E OF ROSCOE (Lat: 42.418550,  Lng: -88.985731),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 38,800 (year 2040),  Design Load: HS 20,  Features Intersected: BURR OAK RD,  Facility Carried by Structure: I-90 S B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 216.692,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 62.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1019902,  Location: 1 MI E OF ROSCOE (Lat: 42.418408,  Lng: -88.985728),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 37,800 (year 2040),  Design Load: HS 20,  Features Intersected: BURR OAK RD,  Facility Carried by Structure: I-90 N B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 216.676,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 78.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1019903,  Location: 1 MI E OF ROSCOE (Lat: 42.411239,  Lng: -88.985611),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 37,800 (year 2040),  Design Load: HS 20,  Features Intersected: STONEBRIDGE TRAIL,  Facility Carried by Structure: I-90 S B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 215.855,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1019904,  Location: 1 MI E OF ROSCOE (Lat: 42.411097,  Lng: -88.985611),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 37,800 (year 2040),  Design Load: HS 20,  Features Intersected: STONEBRIDGE TRAIL,  Facility Carried by Structure: I-90 N B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 215.839,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1019913,  Location: 1 MI E OF ROSCOE (Lat: 42.427931,  Lng: -88.986550),  Route carried "on" structure: Other road ,  Year Built: 1958,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 5,000 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,700 (year 2040),  Design Load: HS 15,  Features Intersected: I-90,  Facility Carried by Structure: ELEVATOR RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.674,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1019917,  Location: 2.5 MI N ILL 173 (Lat: 42.405919,  Lng: -88.984131),  Route carried "on" structure: Other road ,  Year Built: 1958,  Status: Open,  Structure Length: 11.40m (37.40ft),  Average Daily Traffic: 3,700 (year 2017),  Truck Traffic: 19%,  Average Future Daily Traffic: 5,800 (year 2040),  Design Load: HS 15,  Features Intersected: I-90,  Facility Carried by Structure: BELVIDERE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.982,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.2m (108.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 69.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1019919,  Location: 2.5 MI S OF ILL 75 (Lat: 42.456850,  Lng: -88.995189),  Route carried "on" structure: Other road ,  Year Built: 1958,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 2,225 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,900 (year 2040),  Features Intersected: I-90,  Facility Carried by Structure: ROCKTON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.545,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1019921,  Location: 1.5 MI N ILL 173 (Lat: 42.388897,  Lng: -88.974642),  Route carried "on" structure: Other road ,  Year Built: 1958,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 2,250 (year 2017),  Truck Traffic: 16%,  Average Future Daily Traffic: 4,200 (year 2040),  Design Load: HS 15,  Features Intersected: I-90,  Facility Carried by Structure: SWANSON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.524,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 101993,  Location: 1 MI SE OF ROCKTON (Lat: 42.439553,  Lng: -89.042594),  Route carried "on" structure: County highway ,  Year Built: 1925,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 650 (year 2017),  Average Future Daily Traffic: 600 (year 2040),  Design Load: H 15,  Features Intersected: DRY RUN CREEK,  Facility Carried by Structure: HONONEGAH PRES RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 2,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Material/Design: Concrete,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 6.6m (21.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1019951,  Location: 1 MI NE OF ROSCOE (Lat: 42.451883,  Lng: -88.994972),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 75,200 (year 2040),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: I-90
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 220.410,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019
Find on map >>   Show street view

Structure Number: 1019952,  Location: 1 MI E OF ROSCOE (Lat: 42.435314,  Lng: -88.989217),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 2.27m (7.45ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 75,200 (year 2040),  Design Load: HS 20,  Features Intersected: N KINNIKINNICK CREEK,  Facility Carried by Structure: I-90
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 218.559,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 93.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019
Find on map >>   Show street view

Structure Number: 1019953,  Location: 1 MI E OF ROSCOE (Lat: 42.414472,  Lng: -88.985667),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 2.27m (7.45ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 75,600 (year 2040),  Design Load: HS 20,  Features Intersected: S KINNIKINNICK CREEK,  Facility Carried by Structure: I-90
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 216.226,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019
Find on map >>   Show street view

Structure Number: 1019962,  Location: .97 MI S OF BELV. RD (Lat: 42.392981,  Lng: -88.976744),  Route carried "on" structure: Interstate 39,  Year Built: 1958,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 23,400 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 48,300 (year 2040),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: I-90
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 213.667,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 36.6m (120.1ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019
Find on map >>   Show street view

Structure Number: 1019965,  Location: 1 MI E OF ROSCOE (Lat: 42.442422,  Lng: -88.991700),  Route carried "on" structure: Other road ,  Year Built: 2006,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 3,950 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,200 (year 2040),  Design Load: HS 20,  Features Intersected: I-90 (N & W),  Facility Carried by Structure: MCCURRY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.669,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1010031,  Location: 2.6 MI S ILL 75 (Lat: 42.456439,  Lng: -89.019603),  Route carried "under" structure: Other road ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 13,800 (year 2017),  Truck Traffic: 9%,  Features Intersected: ROCKTON ROAD,  Facility Carried by Structure: ILL 251 S B
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 6.518,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.8m (58.4ft)

Find on map >>   Show street view

Structure Number: 1010032,  Location: 2.6 MI S ILL 75 (Lat: 42.456444,  Lng: -89.019331),  Route carried "under" structure: Other road ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 9,100 (year 2017),  Truck Traffic: 7%,  Features Intersected: ROCKTON ROAD,  Facility Carried by Structure: ILL 251 N B
Minimum Vertical Clearance: 5.77m (18.93ft),  Kilometerpoint: 6.550,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.0m (59.1ft)

Find on map >>   Show street view

Structure Number: 1019901,  Location: 1 MI E OF ROSCOE (Lat: 42.418550,  Lng: -88.985731),  Route carried "under" structure: Other road ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 2,050 (year 2017),  Truck Traffic: 5%,  Features Intersected: BURR OAK RD,  Facility Carried by Structure: I-90 S B
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 1.963,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 1019902,  Location: 1 MI E OF ROSCOE (Lat: 42.418533,  Lng: -88.985583),  Route carried "under" structure: Other road ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 2,050 (year 2017),  Truck Traffic: 5%,  Features Intersected: BURR OAK RD,  Facility Carried by Structure: I-90 N B
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 1.979,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 1019913,  Location: 1 MI E OF ROSCOE (Lat: 42.427931,  Lng: -88.986550),  Route carried "under" structure: Interstate 39,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 46,800 (year 2020),  Truck Traffic: 34%,  Features Intersected: I-90,  Facility Carried by Structure: ELEVATOR RD
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 217.706,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1019917,  Location: 2.5 MI N ILL 173 (Lat: 42.405919,  Lng: -88.984131),  Route carried "under" structure: Interstate 39,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 46,800 (year 2020),  Truck Traffic: 34%,  Features Intersected: I-90,  Facility Carried by Structure: BELVIDERE RD
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 215.228,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 1019919,  Location: 2.5 MI S OF ILL 75 (Lat: 42.456850,  Lng: -88.995189),  Route carried "under" structure: Interstate 39,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 46,800 (year 2020),  Truck Traffic: 34%,  Features Intersected: I-90,  Facility Carried by Structure: ROCKTON RD
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 221.005,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 1019921,  Location: 1.5 MI N ILL 173 (Lat: 42.388897,  Lng: -88.974642),  Route carried "under" structure: Interstate 39,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 46,800 (year 2020),  Truck Traffic: 34%,  Features Intersected: I-90,  Facility Carried by Structure: SWANSON RD
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 213.184,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>   Show street view

Structure Number: 1019927,  Location: 1.5 MI SW ROSCOE (Lat: 42.397981,  Lng: -89.045739),  Route carried "under" structure: Other road ,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 1,450 (year 2017),  Truck Traffic: 5%,  Features Intersected: GLEASMAN RD,  Facility Carried by Structure: DM&E RR
Minimum Vertical Clearance: 3.96m (12.99ft),  Kilometerpoint: 2.655,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 8.5m (27.9ft)

Find on map >>   Show street view

Structure Number: 1019945,  Route carried "under" structure: Interstate 39,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 46,800 (year 2020),  Truck Traffic: 34%,  Features Intersected: I-90,  Facility Carried by Structure: Pedestrian Walkway
Minimum Vertical Clearance: 7.32m (24.02ft),  Kilometerpoint: 219.621,  Lanes under structure: 16,  Toll: On toll road,  Material/Design: Steel continuous,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>   Show street view

Structure Number: 1019965,  Location: 1 MI E OF ROSCOE (Lat: 42.442422,  Lng: -88.991700),  Route carried "under" structure: Interstate 39,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 46,800 (year 2020),  Truck Traffic: 34%,  Features Intersected: I-90 (N & W),  Facility Carried by Structure: MCCURRY RD
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 219.380,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.2m (145.0ft)

Discuss Roscoe, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.