Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Sanford, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 131Number of bridges
  • 1,234ft / 376mTotal length
  • 1,194,690Total average daily traffic
  • 138,434Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Sanford
  • No street view available for this location

New bridges in Sanford, NC - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 121950-1959
  • 71960-1969
  • 241970-1979
  • 71980-1989
  • 101990-1999
  • 482000-2009
  • 202010-2019
  • 12020-2022
Reconstructed bridges in Sanford, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21950-1959
  • 01960-1969
  • 41970-1979
  • 11980-1989
Average Bridge Daily Traffic in Sanford, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.8%Very good
  • 60.9%Good
  • 23.4%Satisfactory
  • 7.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 34.4%Very good
  • 40.6%Good
  • 15.6%Satisfactory
  • 6.3%Fair
  • 3.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 20.3%Very good
  • 54.7%Good
  • 17.2%Satisfactory
  • 4.7%Fair
  • 3.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 2.0%Very good
  • 77.6%Good
  • 14.3%Satisfactory
  • 6.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 63.2%Good
  • 31.6%Satisfactory
  • 5.3%Fair
Find on map >>   Show street view

Structure Number: 1050026,  Location: 1.94 MI. N. JCT. NC42 (Lat: 35.495197,  Lng: -79.195183),  Route carried "under" structure: US 421,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: US1/15/501,NC87BUS
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1050026,  Location: 1.94 MI. N. JCT. NC42 (Lat: 35.495197,  Lng: -79.195183),  Route carried "under" structure: US 421,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: US1/15/501,NC87BUS
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1050029,  Location: 0.2 MI. E. JCT. SR1438 (Lat: 35.502906,  Lng: -79.190911),  Route carried "under" structure: Bypass US 1,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 16,500 (year 2017),  Truck Traffic: 12%,  Features Intersected: SR1406
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 1050029,  Location: 0.2 MI. E. JCT. SR1438 (Lat: 35.502906,  Lng: -79.190911),  Route carried "under" structure: Bypass US 1,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 16,500 (year 2017),  Truck Traffic: 12%,  Features Intersected: SR1406
Minimum Vertical Clearance: 5.81m (19.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 1050031,  Location: 2.2 MI. N. JCT. US421 (Lat: 35.523356,  Lng: -79.183722),  Route carried "under" structure: US 15,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 8,250 (year 2019),  Truck Traffic: 12%,  Features Intersected: US1B,US15/501,NC87
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.2m (154.9ft)

Find on map >>   Show street view

Structure Number: 1050031,  Location: 2.2 MI. N. JCT. US421 (Lat: 35.523356,  Lng: -79.183722),  Route carried "under" structure: US 15,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 8,250 (year 2019),  Truck Traffic: 12%,  Features Intersected: US1B,US15/501,NC87
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.2m (154.9ft)

Find on map >>   Show street view

Structure Number: 1050039,  Location: 2.7 MI. N. JCT. NC87 (Lat: 35.561256,  Lng: -79.153225),  Route carried "under" structure: State highway 1415,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 2,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: US1 SBL
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 105004,  Location: 0.7 MI.W.JCT.SR1423 (Lat: 35.577353,  Lng: -79.135300),  Route carried "under" structure: US 1,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 16,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: SR1426
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 22.921,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 105004,  Location: 0.7 MI.W.JCT.SR1423 (Lat: 35.577353,  Lng: -79.135300),  Route carried "under" structure: US 1,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 16,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: SR1426
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 22.921,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 1050041,  Location: 1.0 MI. N. JCT. SR1426 (Lat: 35.587694,  Lng: -79.121969),  Route carried "under" structure: US 1,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 16,750 (year 2019),  Truck Traffic: 14%,  Features Intersected: SR1423
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 1050041,  Location: 1.0 MI. N. JCT. SR1426 (Lat: 35.587694,  Lng: -79.121969),  Route carried "under" structure: US 1,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 16,750 (year 2019),  Truck Traffic: 14%,  Features Intersected: SR1423
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 1050113,  Location: 2.7 MI. N. JCT. NC87 (Lat: 35.561044,  Lng: -79.153025),  Route carried "under" structure: Bypass Interstate 1415,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 2,200 (year 2017),  Truck Traffic: 7%,  Features Intersected: US1 NBL
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 1050115,  Location: 1.1MI.N.JCT.SR1415 (Lat: 35.511272,  Lng: -79.187817),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 16,500 (year 2017),  Truck Traffic: 12%,  Features Intersected: US421N, NC87
Minimum Vertical Clearance: 7.03m (23.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 1050115,  Location: 1.1MI.N.JCT.SR1415 (Lat: 35.511272,  Lng: -79.187817),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: US421N, NC87
Minimum Vertical Clearance: 7.59m (24.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 1050115,  Location: 1.1MI.N.JCT.SR1415 (Lat: 35.511272,  Lng: -79.187817),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 16,500 (year 2017),  Truck Traffic: 12%,  Features Intersected: US421N, NC87
Minimum Vertical Clearance: 7.16m (23.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 1050116,  Location: 1.1 MI. N. JCT. SR1415 (Lat: 35.511028,  Lng: -79.187900),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: US 421 SBL
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1050116,  Location: 1.1 MI. N. JCT. SR1415 (Lat: 35.511028,  Lng: -79.187900),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: US 421 SBL
Minimum Vertical Clearance: 6.14m (20.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1050117,  Location: 1.1 MI. N. JCT.SR1415 (Lat: 35.511458,  Lng: -79.187753),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: US421(FUT) NBL COL
Minimum Vertical Clearance: 7.59m (24.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 1050117,  Location: 1.1 MI. N. JCT.SR1415 (Lat: 35.511458,  Lng: -79.187753),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: US421(FUT) NBL COL
Minimum Vertical Clearance: 7.36m (24.15ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 1050118,  Location: 0.45 MI. W. JCT. US1 BUS (Lat: 35.510836,  Lng: -79.187967),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2019),  Truck Traffic: 12%,  Features Intersected: US421,NC87 SBL COL
Minimum Vertical Clearance: 5.53m (18.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1050118,  Location: 0.45 MI. W. JCT. US1 BUS (Lat: 35.510836,  Lng: -79.187967),  Route carried "under" structure: Bypass US 1,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2019),  Truck Traffic: 12%,  Features Intersected: US421,NC87 SBL COL
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1050119,  Location: 0.45 MI. N. JCT. SR1406 (Lat: 35.508961,  Lng: -79.178839),  Route carried "under" structure: Bypass US 421,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2015),  Truck Traffic: 12%,  Features Intersected: US1BUS
Minimum Vertical Clearance: 6.01m (19.72ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 1050119,  Location: 0.45 MI. N. JCT. SR1406 (Lat: 35.508961,  Lng: -79.178839),  Route carried "under" structure: Bypass US 421,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 12,500 (year 2015),  Truck Traffic: 12%,  Features Intersected: US1BUS
Minimum Vertical Clearance: 5.94m (19.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 1050124,  Location: 0.6 MI.E.JCT. US1BUS. (Lat: 35.507453,  Lng: -79.168314),  Route carried "under" structure: Bypass US 421,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2013),  Truck Traffic: 12%,  Features Intersected: SR1415
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Find on map >>   Show street view

Structure Number: 1050124,  Location: 0.6 MI.E.JCT. US1BUS. (Lat: 35.507453,  Lng: -79.168314),  Route carried "under" structure: Bypass US 421,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2013),  Truck Traffic: 12%,  Features Intersected: SR1415
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Find on map >>   Show street view

Structure Number: 1050125,  Location: 1.2 MI. N. JCT. SR1521 (Lat: 35.498136,  Lng: -79.145028),  Route carried "under" structure: Bypass US 421,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2015),  Truck Traffic: 12%,  Features Intersected: SR1002
Minimum Vertical Clearance: 6.11m (20.05ft),  Kilometerpoint: 44.592,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.1m (148.0ft)

Find on map >>   Show street view

Structure Number: 1050125,  Location: 1.2 MI. N. JCT. SR1521 (Lat: 35.498136,  Lng: -79.145028),  Route carried "under" structure: Bypass US 421,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2015),  Truck Traffic: 12%,  Features Intersected: SR1002
Minimum Vertical Clearance: 5.35m (17.55ft),  Kilometerpoint: 44.592,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.1m (148.0ft)

Find on map >>   Show street view

Structure Number: 1050126,  Location: 0.65 MI. N. JCT. SR1521 (Lat: 35.491292,  Lng: -79.140558),  Route carried "under" structure: Bypass US 421,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1509
Minimum Vertical Clearance: 6.54m (21.46ft),  Kilometerpoint: 44.348,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 1050126,  Location: 0.65 MI. N. JCT. SR1521 (Lat: 35.491292,  Lng: -79.140558),  Route carried "under" structure: Bypass US 421,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1509
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 44.348,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 1050127,  Location: 0.65 MI. S. JCT. SR1506 (Lat: 35.483608,  Lng: -79.133475),  Route carried "under" structure: Alternate US 421,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1521
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 1050127,  Location: 0.65 MI. S. JCT. SR1506 (Lat: 35.483608,  Lng: -79.133475),  Route carried "under" structure: Alternate US 421,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 14%,  Features Intersected: SR1521
Minimum Vertical Clearance: 6.65m (21.82ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 1050128,  Location: 0.8 MI. N. JCT. SR1596 (Lat: 35.472144,  Lng: -79.121656),  Route carried "under" structure: Bypass US 421,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1524
Minimum Vertical Clearance: 5.30m (17.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 1050128,  Location: 0.8 MI. N. JCT. SR1596 (Lat: 35.472144,  Lng: -79.121656),  Route carried "under" structure: Bypass US 421,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1524
Minimum Vertical Clearance: 5.71m (18.73ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 1050129,  Location: 09 MI. N. JCT. US421 BUS (Lat: 35.460511,  Lng: -79.118225),  Route carried "under" structure: State highway 42,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 6,500 (year 2017),  Truck Traffic: 6%,  Features Intersected: US421NB,NC87N BYP.
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.3m (138.8ft)

Find on map >>   Show street view

Structure Number: 105013,  Location: 0.9 MI. N. JCT. US421BUS. (Lat: 35.460600,  Lng: -79.118500),  Route carried "under" structure: State highway 42,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2017),  Truck Traffic: 6%,  Features Intersected: US421S, NC87S BYP.
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.0m (137.8ft)

Find on map >>   Show street view

Structure Number: 1050135,  Location: 1.0 MI. S. JCT. NC42 (Lat: 35.446750,  Lng: -79.118858),  Route carried "under" structure: US 421,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 5,250 (year 2019),  Truck Traffic: 12%,  Features Intersected: US421(FUT),NC87N
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 40.843,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Find on map >>   Show street view

Structure Number: 1050135,  Location: 1.0 MI. S. JCT. NC42 (Lat: 35.446750,  Lng: -79.118858),  Route carried "under" structure: Business US 421,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 5,250 (year 2019),  Truck Traffic: 12%,  Features Intersected: US421(FUT),NC87N
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 40.843,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Find on map >>   Show street view

Structure Number: 1050136,  Location: 0.1 MI. S. JCT. NC42 (Lat: 35.446750,  Lng: -79.118858),  Route carried "under" structure: Bypass US 421,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2019),  Truck Traffic: 12%,  Features Intersected: US421S,NC87S
Minimum Vertical Clearance: 5.10m (16.73ft),  Kilometerpoint: 40.843,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Find on map >>   Show street view

Structure Number: 1050136,  Location: 0.1 MI. S. JCT. NC42 (Lat: 35.446750,  Lng: -79.118858),  Route carried "under" structure: Bypass US 241,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2019),  Truck Traffic: 12%,  Features Intersected: US421S,NC87S,  Facility Carried by Structure: US421S
Minimum Vertical Clearance: 5.10m (16.73ft),  Kilometerpoint: 40.843,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Find on map >>   Show street view

Structure Number: 1050137,  Location: 1.1 MI. S. JCT. US421 (Lat: 35.433783,  Lng: -79.122617),  Route carried "under" structure: Bypass State highway 87,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: NC87 BUS. NBL
Minimum Vertical Clearance: 5.35m (17.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.0m (150.9ft)

Find on map >>   Show street view

Structure Number: 1050137,  Location: 1.1 MI. S. JCT. US421 (Lat: 35.433783,  Lng: -79.122617),  Route carried "under" structure: Bypass State highway 87,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: NC87 BUS. NBL
Minimum Vertical Clearance: 6.19m (20.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.0m (150.9ft)

Find on map >>   Show street view

Structure Number: 1050153,  Location: 1.9 MI. S. JCT. SR2146 (Lat: 35.540689,  Lng: -79.240719),  Route carried "under" structure: US 421,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: US401BUS,SR1400
Minimum Vertical Clearance: 6.14m (20.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.5m (146.0ft)

Find on map >>   Show street view

Structure Number: 1050153,  Location: 1.9 MI. S. JCT. SR2146 (Lat: 35.540689,  Lng: -79.240719),  Route carried "under" structure: US 421,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 14%,  Features Intersected: US401BUS,SR1400
Minimum Vertical Clearance: 6.09m (19.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.5m (146.0ft)

Discuss Sanford, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.