Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Waverly, Iowa (IA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 65Number of bridges
  • 643ft / 196mTotal length
  • 131,761Total average daily traffic
  • 19,203Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Waverly
  • No street view available for this location

New bridges in Waverly, IA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21920-1929
  • 11930-1939
  • 41950-1959
  • 61960-1969
  • 31970-1979
  • 221990-1999
  • 112000-2009
  • 152010-2019
Average Bridge Daily Traffic in Waverly, IA
Average Bridge Truck Traffic in Waverly, IA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 17.5%Very good
  • 37.5%Good
  • 22.5%Satisfactory
  • 15.0%Fair
  • 7.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 42.5%Very good
  • 25.0%Good
  • 15.0%Satisfactory
  • 10.0%Fair
  • 7.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 20.0%Very good
  • 47.5%Good
  • 12.5%Satisfactory
  • 12.5%Fair
  • 7.5%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.8%Excellent
  • 33.3%Very good
  • 31.4%Good
  • 23.5%Satisfactory
  • 2.0%Fair
  • 2.0%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 5.3%Excellent
  • 26.3%Very good
  • 47.4%Good
  • 10.5%Satisfactory
  • 5.3%Fair
  • 5.3%Serious
Find on map >>   Show street view

Structure Number: 502301,  Location: Int of 6th Ave/2st SW (Lat: 42.720028,  Lng: -92.473097),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 1.38m (4.53ft),  Average Daily Traffic: 183 (year 1975),  Average Future Daily Traffic: 183 (year 2041),  Design Load: HL 93,  Features Intersected: SMALL STREAM,  Facility Carried by Structure: 2ND ST SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.154,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 505325,  Location: Int 3rd St/3rd Ave SW (Lat: 42.722831,  Lng: -92.474639),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 1.02m (3.35ft),  Average Daily Traffic: 270 (year 2017),  Average Future Daily Traffic: 270 (year 2041),  Design Load: HL 93,  Features Intersected: DRY RUN CREEK,  Facility Carried by Structure: 3RD AVE SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.705,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 50533,  Location: 0.2 Mi E of 4th St SW (Lat: 42.720933,  Lng: -92.473781),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 627 (year 1998),  Average Future Daily Traffic: 627 (year 2041),  Design Load: HL 93,  Features Intersected: DRY RUN CREEK,  Facility Carried by Structure: 5TH AVE SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.550,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 505335,  Location: 100' E of 6th Ave NW (Lat: 42.726717,  Lng: -92.477906),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 300 (year 1975),  Average Future Daily Traffic: 300 (year 2041),  Design Load: HL 93,  Features Intersected: DRY RUN CREEK,  Facility Carried by Structure: 1ST AVE NW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.519,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 505355,  Location: BETWEEN 5TH & 6TH ST NW (Lat: 42.728625,  Lng: -92.477681),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 350 (year 1975),  Average Future Daily Traffic: 350 (year 2041),  Design Load: HL 93,  Features Intersected: DRY RUN CREEK,  Facility Carried by Structure: 3RD AVE NW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.262,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 50538,  Location: 0.5 MI E OF BREMER RD (Lat: 42.730258,  Lng: -92.444756),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 120 (year 2017),  Average Future Daily Traffic: 120 (year 2041),  Design Load: HL 93,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: 5TH AVE NE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.888,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 505605,  Location: 000000000 (Lat: 42.714344,  Lng: -92.459011),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 25.18m (82.61ft),  Average Daily Traffic: 151 (year 2019),  Average Future Daily Traffic: 151 (year 2041),  Design Load: HL 93,  Features Intersected: CEDAR RIVER,  Facility Carried by Structure: CEDAR RIVER PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.379,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 41.8m (137.1ft),  Curb or Sidewalk Widths: Left: 4.3m (14.1ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 601725,  Location: 1.0 mi. S of Jct. IA #3 (Lat: 42.700564,  Lng: -92.534253),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 200 (year 2017),  Average Future Daily Traffic: 200 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: US 218,  Facility Carried by Structure: 240TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.420,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 60173,  Location: 0.7 Mi. S of Jct. IA #3 (Lat: 42.704983,  Lng: -92.533886),  Route carried "on" structure: US 218,  Year Built: 1996,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 4,500 (year 2041),  Design Load: HS 20,  Features Intersected: OVERFLOW AVE. SAINTS LAK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 324.532,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 601732,  Location: 0.7 mi. S of Jct. Ia. #3 (Lat: 42.705478,  Lng: -92.534228),  Route carried "on" structure: US 218,  Year Built: 1996,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 4,500 (year 2041),  Design Load: HS 20,  Features Intersected: OVERFLOW AVE. SAINTS LAK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 114.119,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 60.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 60174,  Location: 1.1 MI. N OF JCT. IA 3 (Lat: 42.730931,  Lng: -92.533428),  Route carried "on" structure: US 218,  Year Built: 1996,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 7,800 (year 2020),  Truck Traffic: 29%,  Average Future Daily Traffic: 7,800 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB-SHELL ROCK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 327.416,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 50.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 601775,  Location: 2.0 MI. S JCT. IOWA #3 (Lat: 42.693847,  Lng: -92.520353),  Route carried "on" structure: US 218,  Year Built: 1996,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 9,000 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: TRIB TO SHELL ROCK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 322.503,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 601945,  Location: 4.3 MI. S OF JCT. IA 3 (Lat: 42.691611,  Lng: -92.477331),  Route carried "on" structure: Ramp US 218,  Year Built: 1997,  Status: Open,  Structure Length: 8.78m (28.81ft),  Average Daily Traffic: 190 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 190 (year 2040),  Design Load: HS 20,  Features Intersected: US 218
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.784,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 60195,  Location: 4.2 MI. S OF JCT. IA 3 (Lat: 42.692422,  Lng: -92.477150),  Route carried "on" structure: State highway 116,  Year Built: 1997,  Status: Open,  Structure Length: 8.78m (28.81ft),  Average Daily Traffic: 2,950 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,950 (year 2040),  Design Load: HS 20,  Features Intersected: US 218
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.730,  Lanes on structure: 1,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 601955,  Location: 2.0 MI. N OF JCT. IA. 3 (Lat: 42.744647,  Lng: -92.534628),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 910 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 910 (year 2041),  Design Load: HS 20,  Features Intersected: US 218,  Facility Carried by Structure: 210TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.622,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 60.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 604462,  Location: 0.1 MI.S.OF JCT.3 (Lat: 42.723761,  Lng: -92.475650),  Route carried "on" structure: State highway 116,  Year Built: 2015,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 12,500 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 12,500 (year 2040),  Design Load: HL 93,  Features Intersected: DRY RUN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.234,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 60668,  Location: At the Jct. of Iowa #3 (Lat: 42.714828,  Lng: -92.534347),  Route carried "on" structure: US 218,  Year Built: 1996,  Status: Open,  Structure Length: 6.13m (20.11ft),  Average Daily Traffic: 3,400 (year 2020),  Truck Traffic: 30%,  Average Future Daily Traffic: 3,400 (year 2041),  Design Load: HS 20,  Features Intersected: IA 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 325.627,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 606685,  Location: AT THE JCT. OF IA. 3 (Lat: 42.715378,  Lng: -92.534669),  Route carried "on" structure: US 218,  Year Built: 1996,  Status: Open,  Structure Length: 6.13m (20.11ft),  Average Daily Traffic: 3,400 (year 2020),  Truck Traffic: 30%,  Average Future Daily Traffic: 3,400 (year 2041),  Design Load: HS 20,  Features Intersected: IA 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 113.018,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 71.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 601725,  Location: 1.0 mi. S of Jct. IA #3 (Lat: 42.700564,  Lng: -92.534253),  Route carried "under" structure: US 218,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 9,000 (year 2020),  Truck Traffic: 26%,  Features Intersected: US 218,  Facility Carried by Structure: 240TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 324.040,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 601945,  Location: 4.3 MI. S OF JCT. IA 3 (Lat: 42.691611,  Lng: -92.477331),  Route carried "under" structure: US 218,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 4,250 (year 2020),  Truck Traffic: 27%,  Features Intersected: US 218
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 318.917,  Lanes on structure: 1,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 60195,  Location: 4.2 MI. S OF JCT. IA 3 (Lat: 42.692422,  Lng: -92.477150),  Route carried "under" structure: US 218,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 4,250 (year 2020),  Truck Traffic: 27%,  Features Intersected: US 218,  Facility Carried by Structure: IA 116 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 318.938,  Lanes on structure: 1,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.8m (101.0ft)

Find on map >>   Show street view

Structure Number: 601955,  Location: 2.0 MI. N OF JCT. IA. 3 (Lat: 42.744647,  Lng: -92.534628),  Route carried "under" structure: US 218,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 7,700 (year 2020),  Truck Traffic: 29%,  Features Intersected: US 218,  Facility Carried by Structure: 210TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 328.932,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.8m (110.9ft)

Find on map >>   Show street view

Structure Number: 60668,  Location: At the Jct. of Iowa #3 (Lat: 42.714828,  Lng: -92.534347),  Route carried "under" structure: State highway 3,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 3,100 (year 2020),  Truck Traffic: 7%,  Features Intersected: IA 3,  Facility Carried by Structure: NB US 218
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 349.852,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 606685,  Location: AT THE JCT. OF IA. 3 (Lat: 42.715378,  Lng: -92.534669),  Route carried "under" structure: State highway 3,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 3,100 (year 2020),  Truck Traffic: 7%,  Features Intersected: IA 3,  Facility Carried by Structure: SB US 218
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 349.825,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Discuss Waverly, Iowa (IA) on our hugely popular Iowa forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.