Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Russellville, Arkansas (AR)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 73Number of bridges
  • 666ft / 203mTotal length
  • $3,152,000Total costs
  • 522,169Total average daily traffic
  • 29,926Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Russellville
  • No street view available for this location

New bridges in Russellville, AR - historical statistics
  • New bridges - historical statistics
  • 31930-1939
  • 31940-1949
  • 21950-1959
  • 71960-1969
  • 161970-1979
  • 31980-1989
  • 71990-1999
  • 92000-2009
  • 82010-2019
Reconstructed bridges in Russellville, AR - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21960-1969
  • 11970-1979
  • 01980-1989
  • 21990-1999
Average Bridge Daily Traffic in Russellville, AR
Average Bridge Truck Traffic in Russellville, AR
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 60.0%Good
  • 32.5%Satisfactory
  • 7.5%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.5%Excellent
  • 10.0%Very good
  • 52.5%Good
  • 20.0%Satisfactory
  • 15.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.0%Very good
  • 57.5%Good
  • 32.5%Satisfactory
  • 5.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 16.3%Very good
  • 57.1%Good
  • 18.4%Satisfactory
  • 8.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 5.6%Very good
  • 94.4%Good
Find on map >>   Show street view

Structure Number: 23477,  Location: 0.1 Mi. E. of Weir Rd. (Lat: 35.285442,  Lng: -93.104733),  Route carried "on" structure: City street 50500,  Year Built: 2011,  Status: Open,  Structure Length: 2.35m (7.71ft),  Average Daily Traffic: 3,300 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 165 (year 2031),  Features Intersected: Creek,  Facility Carried by Structure: Russell Rd - B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.384,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 23613,  Location: 0.55 Mi N of W Pkway Dr (Lat: 35.296917,  Lng: -93.146556),  Route carried "on" structure: City street 45140,  Year Built: 2012,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 7,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 280 (year 2032),  Design Load: HS 20,  Features Intersected: Prairie Creek,  Facility Carried by Structure: N. Phoenix Ave.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.690,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 23621,  Location: 0.25 MI N JCT US 64 (Lat: 35.285697,  Lng: -93.146739),  Route carried "on" structure: City street 45140,  Year Built: 2014,  Status: Open,  Structure Length: 4.34m (14.24ft),  Average Daily Traffic: 7,500 (year 2018),  Average Future Daily Traffic: 9,600 (year 2038),  Design Load: HL 93,  Features Intersected: Union Pacific Railroad,  Facility Carried by Structure: N. Phoenix Ave.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: A2679,  Location: 0.5 M NE of Yell Co (Lat: 35.228761,  Lng: -93.143889),  Route carried "on" structure: State highway 7,  Year Built: 1950,  Year Reconstructed: 1974,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 23,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 29,377 (year 2028),  Design Load: HS 20,  Features Intersected: Whig Creek-Pope
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 71,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Other Special Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: A268,  Location: 1.52 M NE of Yell Co. (Lat: 35.242778,  Lng: -93.139200),  Route carried "on" structure: State highway 7,  Year Built: 1950,  Year Reconstructed: 1974,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 23,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 29,377 (year 2028),  Design Load: HS 20,  Features Intersected: Whig Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.446,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: A3967,  Location: LM 85.80 om I-40 (Lat: 35.268100,  Lng: -93.069200),  Route carried "on" structure: Interstate 40,  Year Built: 1967,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 17,882 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: OLD COVE RD (CR 273)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 138.082,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: A6917,  Location: 6.33 Mi E SH 333 & I-40 (Lat: 35.309381,  Lng: -93.150939),  Route carried "on" structure: Interstate 40,  Year Built: 2013,  Status: Open,  Structure Length: 17.78m (58.33ft),  Average Daily Traffic: 14,000 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 14,688 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: Illinois Bayou
Minimum Vertical Clearance: 30.44m (99.87ft),  Kilometerpoint: 129.230,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 38.7m (127.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B3967,  Location: 2.36 MI NW OF SH 363 (Lat: 35.267911,  Lng: -93.069550),  Route carried "on" structure: Interstate 40,  Year Built: 1967,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 24%,  Average Future Daily Traffic: 43,100 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: OLD COVE RD (CR 273)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 138.082,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B6917,  Location: 0.75 Mi W of Jct SH 7 (Lat: 35.309189,  Lng: -93.151189),  Route carried "on" structure: Interstate 40,  Year Built: 2013,  Status: Open,  Structure Length: 17.77m (58.30ft),  Average Daily Traffic: 14,000 (year 2018),  Truck Traffic: 33%,  Average Future Daily Traffic: 14,688 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: Illinois Bayou
Minimum Vertical Clearance: 30.44m (99.87ft),  Kilometerpoint: 129.230,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 38.7m (127.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: X0186,  Location: 0.75 M S of Jct I-40 (Lat: 35.298739,  Lng: -93.134039),  Route carried "on" structure: State highway 7,  Year Built: 1972,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 15,000 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 22,991 (year 2028),  Design Load: H 20,  Features Intersected: Engineers Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.494,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.6m (15.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: X0362,  Location: 0.42 M E Jct SH 7 & 64 (Lat: 35.278619,  Lng: -93.126458),  Route carried "on" structure: US 64,  Year Built: 1976,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 15,618 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 19,159 (year 2028),  Design Load: H 20,  Features Intersected: Prairie Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.198,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: X0693,  Location: 0.4 M S of Jct US 64 (Lat: 35.271519,  Lng: -93.091089),  Route carried "on" structure: State highway 324,  Year Built: 1987,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,800 (year 2018),  Truck Traffic: 20%,  Average Future Daily Traffic: 3,065 (year 2028),  Design Load: H 20,  Features Intersected: Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: X0966,  Location: 2.77 M NE of jct. SH 7 (Lat: 35.313231,  Lng: -93.101569),  Route carried "on" structure: State highway 124,  Year Built: 1997,  Status: Open,  Structure Length: 1.42m (4.66ft),  Average Daily Traffic: 4,800 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,500 (year 2034),  Design Load: H 20,  Features Intersected: Shiloh Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.456,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: X0967,  Location: 5.77 MI NE OF JCT SH 7 (Lat: 35.332719,  Lng: -93.061450),  Route carried "on" structure: State highway 124,  Year Built: 1997,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 4,800 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 6,259 (year 2028),  Design Load: H 20,  Features Intersected: Gum Log Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.284,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: X1265,  Location: 0.1 Mi. SW. Jct. SH 7 (Lat: 35.298289,  Lng: -93.137631),  Route carried "on" structure: State highway 872,  Year Built: 1940,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 436 (year 2005),  Truck Traffic: 1%,  Average Future Daily Traffic: 639 (year 2025),  Features Intersected: Engineers Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.559,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: X1266,  Location: 0.30 Mi. SW. Jct. SH 7 (Lat: 35.298589,  Lng: -93.140431),  Route carried "on" structure: State highway 872,  Year Built: 1940,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 436 (year 2005),  Truck Traffic: 1%,  Average Future Daily Traffic: 639 (year 2025),  Design Load: H 20,  Features Intersected: Engineers Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.271,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: X1339,  Location: 0.47 M N jct US 64 (Lat: 35.284989,  Lng: -93.106811),  Route carried "on" structure: State highway 124,  Year Built: 2008,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 19,215 (year 2016),  Truck Traffic: 3%,  Average Future Daily Traffic: 19,797 (year 2027),  Design Load: H 20,  Features Intersected: Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.756,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 3589,  Location: At Jct I-40 & O St. (Lat: 35.296000,  Lng: -93.120431),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2012),  Truck Traffic: 1%,  Features Intersected: I 40-SEC 22,  Facility Carried by Structure: E. 'O' Street
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 132.433,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 3589,  Location: At Jct I-40 & O St. (Lat: 35.296000,  Lng: -93.120431),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2012),  Truck Traffic: 1%,  Features Intersected: I 40-SEC 22,  Facility Carried by Structure: E. 'O' Street
Minimum Vertical Clearance: 5.71m (18.73ft),  Kilometerpoint: 132.433,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5645,  Location: 0.11 M E Jct SH 7 & 64 (Lat: 35.278203,  Lng: -93.131703),  Route carried "under" structure: City street 6160,  Structure Length: 0. m,  Average Daily Traffic: 279 (year 1983),  Truck Traffic: 1%,  Features Intersected: 2 City Sts, RR,  Facility Carried by Structure: US 64-SEC 6
Minimum Vertical Clearance: 3.47m (11.38ft),  Kilometerpoint: 0.080,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5645,  Location: 0.11 M E Jct SH 7 & 64 (Lat: 35.278203,  Lng: -93.131703),  Route carried "under" structure: City street 15700,  Structure Length: 0. m,  Average Daily Traffic: 2,565 (year 1983),  Truck Traffic: 1%,  Features Intersected: 2 City Sts, RR,  Facility Carried by Structure: US 64-SEC 6
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 0.064,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 5645,  Location: 0.11 M E Jct SH 7 & 64 (Lat: 35.278203,  Lng: -93.131703),  Route carried "under" structure: City street ,  Structure Length: 0. m,  Truck Traffic: 1%,  Features Intersected: 2 City sts, RR,  Facility Carried by Structure: US 64-SEC 6
Minimum Vertical Clearance: 4.96m (16.27ft),  Kilometerpoint: 0.966,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6666,  Location: I-40 & SH 331 (Lat: 35.282331,  Lng: -93.092889),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 18%,  Features Intersected: I-40 SEC 22,  Facility Carried by Structure: SH 331 SEC 1
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 135.394,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6666,  Location: I-40 & SH 331 (Lat: 35.282331,  Lng: -93.092889),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 18%,  Features Intersected: I-40 SEC 22,  Facility Carried by Structure: SH 331 SEC 1
Minimum Vertical Clearance: 4.99m (16.37ft),  Kilometerpoint: 135.394,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6803,  Location: @ INTER I 40 & SH 7 (Lat: 35.305731,  Lng: -93.138361),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 1%,  Features Intersected: I 40 -SEC. 22,  Facility Carried by Structure: SH 7 -SEC. 15
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 130.437,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 6803,  Location: @ INTER I 40 & SH 7 (Lat: 35.305731,  Lng: -93.138361),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2013),  Truck Traffic: 1%,  Features Intersected: I 40 -SEC. 22,  Facility Carried by Structure: SH 7 -SEC. 15
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 130.437,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 7007,  Location: 0.2 Mi N. of Jct. US 64 (Lat: 35.321461,  Lng: -93.191061),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: I 40 -SEC. 22,  Facility Carried by Structure: Dwight Mission Rd.
Minimum Vertical Clearance: 5.99m (19.65ft),  Kilometerpoint: 125.126,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 7007,  Location: 0.2 Mi N. of Jct. US 64 (Lat: 35.321461,  Lng: -93.191061),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: I 40 -SEC. 22,  Facility Carried by Structure: Dwight Mission Rd.
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 125.126,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 7014,  Location: 0.85 MI N JCT US 64 (Lat: 35.290450,  Lng: -93.106731),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2012),  Truck Traffic: 1%,  Features Intersected: I 40 - SEC. 22,  Facility Carried by Structure: SH 124
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 133.817,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: 7014,  Location: 0.85 MI N JCT US 64 (Lat: 35.290450,  Lng: -93.106731),  Route carried "under" structure: Interstate 40,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2012),  Truck Traffic: 1%,  Features Intersected: I 40 - SEC. 22,  Facility Carried by Structure: SH 124
Minimum Vertical Clearance: 5.38m (17.65ft),  Kilometerpoint: 133.817,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: A3967,  Location: LM 85.80 om I-40 (Lat: 35.268100,  Lng: -93.069200),  Route carried "under" structure: County highway 273,  Structure Length: 0. m,  Average Daily Traffic: 89 (year 1983),  Truck Traffic: 1%,  Features Intersected: OLD COVE RD (CR 273),  Facility Carried by Structure: I 40-SEC 22, WB LN
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.097,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Structure Number: B3967,  Location: 2.36 MI NW OF SH 363 (Lat: 35.267911,  Lng: -93.069550),  Route carried "under" structure: County highway 273,  Structure Length: 0. m,  Average Daily Traffic: 89 (year 1983),  Truck Traffic: 1%,  Features Intersected: OLD COVE RD (CR 273),  Facility Carried by Structure: I 40-SEC 22, EB LN
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 0.080,  Length of Maximum Span: 0.0m

Discuss Russellville, Arkansas (AR) on our hugely popular Arkansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.