Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Shelbyville, Kentucky (KY)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 64Number of bridges
  • 771ft / 235mTotal length
  • $3,019,000Total costs
  • 579,700Total average daily traffic
  • 94,763Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Shelbyville
  • No street view available for this location

New bridges in Shelbyville, KY - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21930-1939
  • 31940-1949
  • 41950-1959
  • 171960-1969
  • 31970-1979
  • 141980-1989
  • 81990-1999
  • 72000-2009
  • 52010-2019
Reconstructed bridges in Shelbyville, KY - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 01990-1999
  • 22000-2009
Average Bridge Daily Traffic in Shelbyville, KY
Average Bridge Truck Traffic in Shelbyville, KY
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 35.4%Good
  • 31.3%Satisfactory
  • 22.9%Fair
  • 10.4%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.1%Very good
  • 25.0%Good
  • 47.9%Satisfactory
  • 18.8%Fair
  • 4.2%Poor
  • 2.1%Imminent failure
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 29.2%Good
  • 37.5%Satisfactory
  • 25.0%Fair
  • 6.3%Poor
  • 2.1%Imminent failure
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 28.6%Good
  • 51.0%Satisfactory
  • 20.4%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 11.1%Good
  • 44.4%Satisfactory
  • 44.4%Fair
Find on map >>   Show street view

Structure Number: 106C00047N,  Location: 0.1 MI N OF US 60 WB (Lat: 38.212500,  Lng: -85.215000),  Route carried "on" structure: County highway 1329,  Year Built: 1982,  Status: Closed,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 145 (year 2006),  Average Future Daily Traffic: 199 (year 2026),  Features Intersected: CLEAR CREEK,  Facility Carried by Structure: JAIL HILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.650,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.1m (88.9ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 3.2m (10.5ft),  Out-to-Out Width: 3.8m (12.5ft)

Condition: Deck: Satisfactory,  Superstructure: Imminent failure,  Substructure: Imminent failure,  Channel: Satisfactory,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.28m (0.92ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $224,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $244,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 106C00049N,  Location: 1.5 MI S OF KY 362 (Lat: 38.272778,  Lng: -85.289444),  Route carried "on" structure: County highway 1310,  Year Built: 1985,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 71 (year 2014),  Average Future Daily Traffic: 2,034 (year 2034),  Design Load: HS 20,  Features Intersected: BULLSKIN CREEK,  Facility Carried by Structure: HEBRON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.398,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 87.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00051N,  Location: 2.2 MI E OF KY 362 (Lat: 38.263611,  Lng: -85.302222),  Route carried "on" structure: County highway 1312,  Year Built: 1986,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 299 (year 2014),  Average Future Daily Traffic: 2,034 (year 2034),  Design Load: HS 20,  Features Intersected: BULLSKIN CREEK,  Facility Carried by Structure: ANDERSON LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.592,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.0m (52.5ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.18m (0.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $158,000,  Total Project Cost: $157,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00052N,  Location: 2.9 MI E OF KY 1848 (Lat: 38.240833,  Lng: -85.290000),  Route carried "on" structure: County highway 1309,  Year Built: 1986,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 112 (year 2014),  Average Future Daily Traffic: 2,034 (year 2034),  Design Load: HS 20,  Features Intersected: BULLSKIN CREEK,  Facility Carried by Structure: ANTIOCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.598,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 85.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00054N,  Location: 1.6 MI W OF KY 55 (Lat: 38.274167,  Lng: -85.233333),  Route carried "on" structure: County highway 1301,  Year Built: 1987,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 67 (year 2014),  Average Future Daily Traffic: 2,034 (year 2034),  Design Load: HS 20,  Features Intersected: FOX RUN,  Facility Carried by Structure: FOX RUN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.996,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00056N,  Location: 2.2 MI S OF KY 53 (Lat: 38.158889,  Lng: -85.182500),  Route carried "on" structure: County highway 1116,  Year Built: 1988,  Status: Open,  Structure Length: 2.33m (7.64ft),  Average Daily Traffic: 250 (year 2010),  Average Future Daily Traffic: 217 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: GUIST CREEK,  Facility Carried by Structure: ROCKBRIDGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.201,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 77.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00059N,  Location: 1.5 MI E OF KY 55 (Lat: 38.268333,  Lng: -85.177500),  Route carried "on" structure: County highway 1003,  Year Built: 1989,  Status: Open,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 106 (year 2014),  Average Future Daily Traffic: 2,034 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: CLEAR CREEK,  Facility Carried by Structure: CLEAR CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.375,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 68.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00060N,  Location: 0.6 MI W OF KY 1871 (Lat: 38.217500,  Lng: -85.188611),  Route carried "on" structure: County highway 1001,  Year Built: 1991,  Status: Posted for load,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 2,685 (year 2019),  Average Future Daily Traffic: 2,497 (year 2039),  Design Load: HS 20,  Features Intersected: TRIB TO CLEAR CREEK,  Facility Carried by Structure: BENSON PIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.587,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 43.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00066N,  Location: 250 FT S OF CLEAR CR RD (Lat: 38.268611,  Lng: -85.176111),  Route carried "on" structure: County highway 1002,  Year Built: 1992,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 189 (year 2014),  Average Future Daily Traffic: 2,034 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: E CLEAR CREEK,  Facility Carried by Structure: BELLVIEW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.065,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.7m (15.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00070N,  Location: 0.5 MI E OF KY 55 (Lat: 38.217222,  Lng: -85.196944),  Route carried "on" structure: County highway 1001,  Year Built: 1993,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 2,685 (year 2019),  Average Future Daily Traffic: 2,497 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: TRIB TO CLEAR CREEK,  Facility Carried by Structure: BENSON PIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.850,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.3m (40.4ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00079N,  Location: 175 FT E OF KY 55 (Lat: 38.197222,  Lng: -85.267222),  Route carried "on" structure: County highway 1247,  Year Built: 1996,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 295 (year 2006),  Average Future Daily Traffic: 406 (year 2026),  Design Load: HS 25 or greater,  Features Intersected: DRY RUN,  Facility Carried by Structure: OLD BRUNERSTOWN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.326,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.3m (40.4ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 52.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00081N,  Location: 2.9 MI S OF KY 53 (Lat: 38.149444,  Lng: -85.176667),  Route carried "on" structure: County highway 1116,  Year Built: 1997,  Status: Open,  Structure Length: 2.30m (7.55ft),  Average Daily Traffic: 121 (year 2010),  Average Future Daily Traffic: 105 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: JEPTHA CREEK,  Facility Carried by Structure: ROCKBRIDGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.932,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 6.8m (22.3ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 85.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00083N,  Location: 100 FT E OF KY 55 (Lat: 38.209444,  Lng: -85.261944),  Route carried "on" structure: County highway 1239,  Year Built: 1998,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 1,710 (year 2006),  Average Future Daily Traffic: 2,352 (year 2026),  Design Load: HS 25 or greater,  Features Intersected: DRY RUN,  Facility Carried by Structure: BROOKS INDUSTRIAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.039,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 106C00085N,  Location: 0.5 MI W OF KY 2861 (Lat: 38.131667,  Lng: -85.270556),  Route carried "on" structure: County highway 1207,  Year Built: 2007,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 54 (year 2010),  Average Future Daily Traffic: 46 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: WISE RUN,  Facility Carried by Structure: OLIVE BRANCH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.326,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 62.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106C00087N,  Location: 0.5 MI E OF BURKS BR RD (Lat: 38.233333,  Lng: -85.219444),  Route carried "on" structure: City street 1177,  Year Built: 1987,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 50 (year 2009),  Average Future Daily Traffic: 50 (year 2029),  Features Intersected: TRIB TO SHELBY LAKE,  Facility Carried by Structure: DON CUBERT DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.814,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 36.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Open Grating,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 106C00091N,  Location: 0.55 MI E OF KY 55 (Lat: 38.190556,  Lng: -85.266944),  Route carried "on" structure: City street 1181,  Year Built: 2015,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 210 (year 2017),  Average Future Daily Traffic: 256 (year 2037),  Design Load: Greater than HL93,  Features Intersected: DRY RUN,  Facility Carried by Structure: GORDON LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.217,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 50.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 106B00009N,  Location: 1.9 MI S OF US 60 (Lat: 38.184722,  Lng: -85.212222),  Route carried "under" structure: Interstate 64,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 41,274 (year 2020),  Truck Traffic: 20%,  Features Intersected: I-64,  Facility Carried by Structure: KY 53
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 56.515,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 106B00019N,  Location: 0.6 MI S OF US 60 (Lat: 38.206111,  Lng: -85.264444),  Route carried "under" structure: State highway 55,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 19,117 (year 2013),  Truck Traffic: 10%,  Features Intersected: KY 55,  Facility Carried by Structure: NS RAILROAD
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 11.780,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Find on map >>   Show street view

Structure Number: 106B00039N,  Location: 1.9 MI S OF US 60 (Lat: 38.185278,  Lng: -85.239444),  Route carried "under" structure: Interstate 64,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 41,274 (year 2020),  Truck Traffic: 20%,  Features Intersected: I-64,  Facility Carried by Structure: KY 2861
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 54.135,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 106B00047N,  Location: 1.0 MI W OF KY 714 (Lat: 38.173056,  Lng: -85.159444),  Route carried "under" structure: Interstate 64,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 38,204 (year 2020),  Truck Traffic: 22%,  Features Intersected: I-64,  Facility Carried by Structure: KY 1790
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 61.359,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.3m (56.8ft)

Find on map >>   Show street view

Structure Number: 106B00109N,  Location: 1.55 MI S OF US 60 (Lat: 38.192222,  Lng: -85.271667),  Route carried "under" structure: Interstate 64,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 50,900 (year 2011),  Truck Traffic: 17%,  Features Intersected: I-64,  Facility Carried by Structure: KY 55
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 51.196,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.2m (145.0ft)

Find on map >>   Show street view

Structure Number: 106R00600N,  Location: 0.15 MI N OF US 60 WB (Lat: 38.214444,  Lng: -85.218611),  Route carried "under" structure: City street 1001,  Year Built: 1924,  Structure Length: 0. m,  Average Daily Traffic: 5,142 (year 2019),  Features Intersected: 7TH ST,  Facility Carried by Structure: RJ CORMAN RAILROAD
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.150,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 106R00604N,  Location: 0.15 MI S OF US 60 EB (Lat: 38.208889,  Lng: -85.213056),  Route carried "under" structure: City street 1122,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 1,307 (year 2019),  Features Intersected: 3RD ST,  Facility Carried by Structure: NS RAILROAD
Minimum Vertical Clearance: 3.71m (12.17ft),  Kilometerpoint: 0.356,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 10.7m (35.1ft)