Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Auburn, Washington (WA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 51Number of bridges
  • 915ft / 279mTotal length
  • $253,058,000Total costs
  • 1,818,391Total average daily traffic
  • 172,028Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Auburn
  • No street view available for this location

New bridges in Auburn, WA - historical statistics
  • New bridges - historical statistics
  • 71950-1959
  • 21960-1969
  • 221970-1979
  • 31980-1989
  • 41990-1999
  • 82000-2009
  • 52010-2019
Reconstructed bridges in Auburn, WA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Auburn, WA
Average Bridge Truck Traffic in Auburn, WA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.6%Very good
  • 50.0%Good
  • 25.0%Satisfactory
  • 19.4%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.8%Very good
  • 66.7%Good
  • 19.4%Satisfactory
  • 11.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.6%Very good
  • 72.2%Good
  • 19.4%Satisfactory
  • 2.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 50.0%Good
  • 25.0%Fair
Find on map >>   Show street view

Structure Number: 6066A,  Location: JCT SR 18 (Lat: 47.302972,  Lng: -122.225833),  Route carried "under" structure: State highway 164,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 27,718 (year 2019),  Truck Traffic: 4%,  Features Intersected: SR 164,  Facility Carried by Structure: SR 18
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.499,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 24.1m (79.1ft)

Find on map >>   Show street view

Structure Number: 8853A,  Location: 0.1 N JCT SR 18 (Lat: 47.308364,  Lng: -122.249500),  Route carried "under" structure: State highway 167,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 44,417 (year 2019),  Truck Traffic: 10%,  Features Intersected: SR 167,  Facility Carried by Structure: W MAIN ST
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 23.770,  Lanes on structure: 4,  Lanes under structure: 7,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 44.5m (146.0ft)

Find on map >>   Show street view

Structure Number: 8853B,  Location: 1.1 N JCT SR 18 (Lat: 47.322417,  Lng: -122.245528),  Route carried "under" structure: State highway 167,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 116,482 (year 2019),  Truck Traffic: 10%,  Features Intersected: SR 167,  Facility Carried by Structure: 15TH ST NW
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 25.379,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 8853C,  Location: 2.3 N JCT SR 18 (Lat: 47.340167,  Lng: -122.245389),  Route carried "under" structure: State highway 167,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 132,510 (year 2019),  Truck Traffic: 10%,  Features Intersected: SR 167,  Facility Carried by Structure: 37TH ST NW
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 27.359,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.1m (134.8ft)

Find on map >>   Show street view

Structure Number: 9236A,  Location: 2.3 N PIERCE CO (Lat: 47.295694,  Lng: -122.257778),  Route carried "under" structure: State highway 167,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 92,539 (year 2019),  Truck Traffic: 10%,  Features Intersected: SR 167,  Facility Carried by Structure: 15TH ST SW
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 22.289,  Lanes on structure: 6,  Lanes under structure: 5,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 46.3m (151.9ft)

Find on map >>   Show street view

Structure Number: 9236B,  Location: 2.3 E JCT I-5 (Lat: 47.301889,  Lng: -122.252778),  Route carried "under" structure: State highway 18,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 60,520 (year 2019),  Truck Traffic: 9%,  Features Intersected: SR 18,  Facility Carried by Structure: SR 167 NB
Minimum Vertical Clearance: 7.06m (23.16ft),  Kilometerpoint: 4.651,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 9236C,  Location: 2.3 E JCT I-5 (Lat: 47.301944,  Lng: -122.253278),  Route carried "under" structure: State highway 18,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 60,520 (year 2019),  Truck Traffic: 9%,  Features Intersected: SR 18,  Facility Carried by Structure: SR 167
Minimum Vertical Clearance: 6.45m (21.16ft),  Kilometerpoint: 4.619,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 9236D,  Location: 2.7 N PIERCE CO (Lat: 47.299500,  Lng: -122.253000),  Route carried "under" structure: Ramp State highway 167,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 10,471 (year 2019),  Truck Traffic: 19%,  Features Intersected: N-E RAMP,  Facility Carried by Structure: NB RAMP
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 0.579,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 9236F,  Location: 2.3 E JCT I-5 (Lat: 47.301889,  Lng: -122.252417),  Route carried "under" structure: State highway 18,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 60,520 (year 2019),  Truck Traffic: 9%,  Features Intersected: SR 18,  Facility Carried by Structure: SR 167 RAMP
Minimum Vertical Clearance: 6.65m (21.82ft),  Kilometerpoint: 4.683,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 12555A,  Location: 0.6 E JCT SR 164 (Lat: 47.303472,  Lng: -122.213667),  Route carried "under" structure: City street ,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 18,226 (year 2017),  Truck Traffic: 5%,  Features Intersected: M STREET,  Facility Carried by Structure: SR 18
Minimum Vertical Clearance: 10.79m (35.40ft),  Kilometerpoint: 1.030,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.3m (119.1ft)

Find on map >>   Show street view

Structure Number: 14354A,  Location: 2.3 E JCT SR 164 (Lat: 47.300139,  Lng: -122.180550),  Route carried "under" structure: County highway ,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 9,224 (year 2016),  Truck Traffic: 5%,  Features Intersected: BNRR, AUBURN-BLK DIAMOND,  Facility Carried by Structure: SR 18
Minimum Vertical Clearance: 8.46m (27.76ft),  Kilometerpoint: 0.209,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 18665A,  Location: 2.3 E JCT I-5 (Lat: 47.301972,  Lng: -122.253000),  Route carried "under" structure: State highway 18,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 60,520 (year 2019),  Truck Traffic: 9%,  Features Intersected: SR 18,  Facility Carried by Structure: SR 167 SB HOV
Minimum Vertical Clearance: 6.88m (22.57ft),  Kilometerpoint: 4.635,  Lanes on structure: 1,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 56.1m (184.1ft)

Find on map >>   Show street view

Structure Number: 89201,  Location: 0.1 MI N OF SR 18 (Lat: 47.303875,  Lng: -122.213611),  Route carried "under" structure: City street 55,  Year Built: 2014,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2020),  Truck Traffic: 5%,  Features Intersected: M Street,  Facility Carried by Structure: BNSF MAIN LINE
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.001,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 89202,  Location: 0.1 MI N OF SR 18 (Lat: 47.303803,  Lng: -122.213611),  Route carried "under" structure: City street 55,  Year Built: 2018,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2020),  Truck Traffic: 15%,  Features Intersected: M STREET,  Facility Carried by Structure: BNSF SIDING LINE
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.001,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 27.7m (90.9ft)

Discuss Auburn, Washington (WA) on our hugely popular Washington forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.