Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Baytown, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 159Number of bridges
  • 6,939ft / 2,115mTotal length
  • $2,476,000Total costs
  • 2,951,988Total average daily traffic
  • 350,483Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Baytown
  • No street view available for this location

New bridges in Baytown, TX - historical statistics
  • New bridges - historical statistics
  • 21930-1939
  • 21940-1949
  • 41950-1959
  • 81960-1969
  • 381970-1979
  • 161980-1989
  • 241990-1999
  • 552000-2009
  • 92010-2019
  • 12020-2022
Reconstructed bridges in Baytown, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 01950-1959
  • 11960-1969
  • 41970-1979
  • 11980-1989
  • 21990-1999
  • 32000-2009
Average Bridge Daily Traffic in Baytown, TX
Average Bridge Truck Traffic in Baytown, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.7%Very good
  • 67.0%Good
  • 23.6%Satisfactory
  • 3.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.2%Very good
  • 60.4%Good
  • 22.6%Satisfactory
  • 2.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.7%Very good
  • 52.8%Good
  • 34.9%Satisfactory
  • 6.6%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.1%Very good
  • 47.7%Good
  • 34.9%Satisfactory
  • 9.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 82.4%Good
  • 11.8%Satisfactory
  • 5.9%Fair
Find on map >>   Show street view

Structure Number: 200360AA0365002,  Location: 0.95 MI N OF FM 99 (Lat: 29.740192,  Lng: -94.921506),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Posted for load,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 2,470 (year 2015),  Average Future Daily Traffic: 4,540 (year 2035),  Features Intersected: CEDAR BAYOU TRIBUTARY,  Facility Carried by Structure: W BAY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.506,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 0.98m (3.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $2,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $3,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Structure Number: 121020038903087,  Location: 2.70 MI E OF SPUR 330,  Route carried "under" structure: Business State highway 146,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 32,680 (year 2016),  Truck Traffic: 10%,  Features Intersected: SH 146 BUS
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 17.801,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 12102003891209,  Location: 0.6 MI N OF SH 225 (Lat: 29.712914,  Lng: -95.003225),  Route carried "under" structure: State highway 146,  Year Built: 1995,  Structure Length: 0. m,  Truck Traffic: 8%,  Features Intersected: HOUSTON SHIP CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.830,  Lanes on structure: 4,  Material/Design: Steel,  Design/Construction: Suspension,  Length of Maximum Span: 381.0m (1,250.0ft)

Structure Number: 121020038913062,  Location: 0.85 MI NE OF SH 146 BUS,  Route carried "under" structure: City street ,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: WEST MAIN STREET,  Facility Carried by Structure: SH 146 NB
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Structure Number: 121020038913063,  Location: 1.4 MI N OF BU 146,  Route carried "under" structure: City street ,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: UPRR,MARKET & LEFEVRE ST,  Facility Carried by Structure: SH 146 NB
Minimum Vertical Clearance: 7.52m (24.67ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Structure Number: 121020038913096,  Location: 0.85 MI NE OF SH 146 BUS,  Route carried "under" structure: City street ,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: WEST MAIN STREET,  Facility Carried by Structure: SH 146 SB
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Structure Number: 121020038913097,  Location: 1.4 MI N OF BU 146,  Route carried "under" structure: City street ,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: UPRR,MARKET & LEFEVRE ST,  Facility Carried by Structure: SH 146 SB
Minimum Vertical Clearance: 7.75m (25.43ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Structure Number: 121020038913106,  Location: 0.30 MI NE OF SH 146 BUS,  Route carried "under" structure: City street ,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 4,640 (year 2010),  Features Intersected: MISSOURI ST,  Facility Carried by Structure: SH 146
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.002,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Structure Number: 121020038913109,  Location: 0.50 MI SW OF SPUR 330,  Route carried "under" structure: City street ,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: W TEXAS AVE,  Facility Carried by Structure: SH 146
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Structure Number: 12102003891311,  Location: AT BU 146 & SH 146 INTER.,  Route carried "under" structure: State highway 146,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 46,390 (year 2013),  Truck Traffic: 8%,  Features Intersected: SH 146 ML
Minimum Vertical Clearance: 7.47m (24.51ft),  Kilometerpoint: 26.281,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 67.1m (220.1ft)

Structure Number: 121020038913111,  Location: 0.40 MI E OF SPUR 330,  Route carried "under" structure: City street ,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: GOOSE CREEK, GARTH RD,  Facility Carried by Structure: SH 146
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 121020038913112,  Location: 1.45 MI E OF SPUR 330 (Lat: 29.750589,  Lng: -94.963397),  Route carried "under" structure: City street ,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2010),  Truck Traffic: 8%,  Features Intersected: NORTH MAIN ST,  Facility Carried by Structure: SH 146
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Structure Number: 121020038913118,  Location: AT JCT SH146 AND SPUR330,  Route carried "under" structure: State highway 146,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 42,300 (year 2010),  Features Intersected: SH 146, SP330, DECKER DR
Minimum Vertical Clearance: 9.65m (31.66ft),  Kilometerpoint: 22.180,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Structure Number: 121020038913268,  Location: AT INT SH 146 & SPUR 330,  Route carried "under" structure: Spur State highway 330,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 10,950 (year 2013),  Truck Traffic: 11%,  Features Intersected: SPUR 330,  Facility Carried by Structure: SH 146 SB
Minimum Vertical Clearance: 6.04m (19.82ft),  Kilometerpoint: 8.420,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Structure Number: 121020038913269,  Location: AT INT SH 146 & SPUR 330,  Route carried "under" structure: Spur State highway 330,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 43,180 (year 2013),  Truck Traffic: 11%,  Features Intersected: SPUR 330,  Facility Carried by Structure: SH 146 NB
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 8.385,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 121020038913343,  Location: AT INT SH 146 & SPUR 330 (Lat: 29.752806,  Lng: -94.990625),  Route carried "under" structure: Spur State highway 330,  Year Built: 2010,  Structure Length: 0. m,  Average Daily Traffic: 26,030 (year 2013),  Truck Traffic: 9%,  Features Intersected: SH 146 SB FR
Minimum Vertical Clearance: 6.22m (20.41ft),  Kilometerpoint: 0.002,  Lanes on structure: 1,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 67.1m (220.1ft)

Structure Number: 121020038913344,  Location: AT INT SH 146 & SPUR 330,  Route carried "under" structure: State highway 146,  Year Built: 2010,  Structure Length: 0. m,  Average Daily Traffic: 25,520 (year 2011),  Truck Traffic: 5%,  Features Intersected: SH 146
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 0.000,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.2m (145.0ft)

Find on map >>   Show street view

Structure Number: 121020038913345,  Location: AT INT SH 146 & SPUR 330 (Lat: 29.748347,  Lng: -94.987256),  Route carried "under" structure: Spur State highway 330,  Year Built: 2010,  Structure Length: 0. m,  Average Daily Traffic: 26,030 (year 2013),  Truck Traffic: 9%,  Features Intersected: SPUR 330 EB
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.002,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121020038913358,  Location: AT INT OF SH 146 & S 330 (Lat: 29.749853,  Lng: -94.981769),  Route carried "under" structure: ServiceState highway 146,  Year Built: 2010,  Structure Length: 0. m,  Average Daily Traffic: 7,190 (year 2013),  Truck Traffic: 8%,  Features Intersected: SH 146 SB FR
Minimum Vertical Clearance: 16.87m (55.35ft),  Kilometerpoint: 0.002,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 121020050801197,  Location: 0.50 MI E OF CROSBY/LYNCH (Lat: 29.791239,  Lng: -95.049872),  Route carried "under" structure: Interstate 10,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 78,960 (year 2013),  Truck Traffic: 20%,  Features Intersected: IH 10,  Facility Carried by Structure: SPUR 330 WB
Minimum Vertical Clearance: 5.72m (18.77ft),  Kilometerpoint: 75.736,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.3m (83.0ft)

Find on map >>   Show street view

Structure Number: 121020050801224,  Location: 0.45 MI E OF CROSBY/LYNCH (Lat: 29.790006,  Lng: -95.050447),  Route carried "under" structure: Spur State highway 330,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 13,900 (year 2011),  Truck Traffic: 10%,  Features Intersected: SPUR 330 EB,  Facility Carried by Structure: IH 10 EB ON RP
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 0.380,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Structure Number: 121020050801331,  Location: 7.75 MI E OF SAN JAC RIV,  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2010),  Truck Traffic: 10%,  Features Intersected: SJOLANDER RD,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 86.782,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>   Show street view

Structure Number: 121020050801333,  Location: 6.0 MI E OF SAN JAC RIVER (Lat: 29.808119,  Lng: -94.964806),  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2010),  Truck Traffic: 10%,  Features Intersected: NORTH MAIN ST,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 84.143,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.7m (117.1ft)

Structure Number: 121020050801334,  Location: 5.0 MI E OF SAN JAC RIVER,  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2010),  Truck Traffic: 10%,  Features Intersected: GARTH RD,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 82.513,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Structure Number: 121020050801335,  Location: 4.0 MI E OF SAN JAC RIVER,  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2010),  Truck Traffic: 10%,  Features Intersected: JOHN MARTIN RD,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 5.87m (19.26ft),  Kilometerpoint: 80.956,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 121020050801336,  Location: 2.1 MI W OF GARTH RD (Lat: 29.799806,  Lng: -95.017494),  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 2,500 (year 2011),  Truck Traffic: 10%,  Features Intersected: UP RR & WADE RD,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 7.95m (26.08ft),  Kilometerpoint: 79.051,  Lanes on structure: 8,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Structure Number: 121020050801337,  Location: 1.2 MI E OF SPUR 330,  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 3,500 (year 2011),  Truck Traffic: 10%,  Features Intersected: THOMPSON RD,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 77.566,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>   Show street view

Structure Number: 121020050807303,  Location: 1.10 MI SE OF IH 10 (Lat: 29.783003,  Lng: -95.031569),  Route carried "under" structure: City street ,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2011),  Truck Traffic: 8%,  Features Intersected: BAYWAY DR,  Facility Carried by Structure: SPUR 330 WB
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 1.770,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 121020050807304,  Location: 1.10 MI SE OF IH 10 (Lat: 29.783056,  Lng: -95.032528),  Route carried "under" structure: City street ,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2011),  Truck Traffic: 8%,  Features Intersected: BAYWAY DR,  Facility Carried by Structure: SPUR 330 EB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 1.770,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Structure Number: 121020050807305,  Location: 2.5 MI SE OF IH 10,  Route carried "under" structure: City street ,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 3,500 (year 2011),  Truck Traffic: 8%,  Features Intersected: MPRR, WADE RD, BAKER RD,  Facility Carried by Structure: SPUR 330 WB
Minimum Vertical Clearance: 7.34m (24.08ft),  Kilometerpoint: 4.023,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Structure Number: 121020050807306,  Location: 2.50 MI SE OF IH 10,  Route carried "under" structure: City street ,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 3,500 (year 2011),  Truck Traffic: 8%,  Features Intersected: MPRR, WADE RD, BAKER RD,  Facility Carried by Structure: SPUR 330 EB
Minimum Vertical Clearance: 7.24m (23.75ft),  Kilometerpoint: 4.023,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Structure Number: 121020050807307,  Location: 0.85 MI NW OF SH 146,  Route carried "under" structure: City street ,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 28,860 (year 2010),  Truck Traffic: 10%,  Features Intersected: ROLLINGBROOK DRIVE,  Facility Carried by Structure: SPUR 330 EB
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 76.347,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Structure Number: 121020050807308,  Location: 0.85 MI NW OF SH 146,  Route carried "under" structure: City street ,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 28,860 (year 2010),  Truck Traffic: 10%,  Features Intersected: ROLLINGBROOK DRIVE,  Facility Carried by Structure: SPUR 330 WB
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 6.960,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Structure Number: 121020050807343,  Location: 0.45 MI NW OF SH 146,  Route carried "under" structure: Spur State highway 330,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 11,000 (year 2010),  Truck Traffic: 11%,  Features Intersected: SPUR 330 WB
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 77.907,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 200360050802328,  Location: IH 10 @ SH 146 (Lat: 29.821767,  Lng: -94.898489),  Route carried "under" structure: Interstate 146,  Year Built: 2000,  Structure Length: 0. m,  Average Daily Traffic: 56,410 (year 2016),  Truck Traffic: 24%,  Features Intersected: SH 146,  Facility Carried by Structure: IH 10
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 1.033,  Lanes on structure: 6,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.8m (124.0ft)

Find on map >>   Show street view

Structure Number: 200360351010031,  Location: 2.8 MI S OF IH 10 (Lat: 29.786214,  Lng: -94.871753),  Route carried "under" structure: State highway 565,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 7,730 (year 2013),  Truck Traffic: 3%,  Features Intersected: FM 565,  Facility Carried by Structure: SH 99 SB
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 1.146,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 200360351010032,  Location: 2.8 MI S OF IH 10 (Lat: 29.784944,  Lng: -94.871881),  Route carried "under" structure: State highway 565,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 7,730 (year 2013),  Truck Traffic: 3%,  Features Intersected: FM 565,  Facility Carried by Structure: SH 99 NB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 1.146,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Discuss Baytown, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.