Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for East Chicago, Indiana (IN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 81Number of bridges
  • 2,349ft / 716mTotal length
  • $2,949,000Total costs
  • 1,148,995Total average daily traffic
  • 108,426Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for East Chicago
  • No street view available for this location

New bridges in East Chicago, IN - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 271950-1959
  • 121960-1969
  • 41970-1979
  • 151980-1989
  • 171990-1999
  • 22010-2019
  • 32020-2022
Reconstructed bridges in East Chicago, IN - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 91980-1989
  • 11990-1999
  • 52000-2009
  • 72010-2019
Average Bridge Daily Traffic in East Chicago, IN
Average Bridge Truck Traffic in East Chicago, IN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 8.3%Excellent
  • 5.6%Very good
  • 33.3%Good
  • 36.1%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.8%Excellent
  • 5.6%Very good
  • 36.1%Good
  • 30.6%Satisfactory
  • 25.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.8%Excellent
  • 8.3%Very good
  • 41.7%Good
  • 22.2%Satisfactory
  • 25.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.7%Excellent
  • 30.8%Very good
  • 30.8%Good
  • 23.1%Satisfactory
  • 7.7%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Satisfactory
  • 50.0%Fair
Find on map >>   Show street view

Structure Number: 8,  Location: 01.12 N SR 101 (Lat: 39.442861,  Lng: -85.023797),  Route carried "on" structure: State highway 1,  Year Built: 1931,  Year Reconstructed: 1961,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 3,563 (year 2014),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,831 (year 2033),  Design Load: H 20,  Features Intersected: BUTLERS RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.896,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 31,  Location: 01.14 S SR 67 (Lat: 40.337811,  Lng: -85.149631),  Route carried "on" structure: State highway 1,  Year Built: 1985,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 1,779 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 6,175 (year 2030),  Design Load: HS 20,  Features Intersected: HALFWAY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.380,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.1m (23.3ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 31,  Location: 00.51 W US 20 (Lat: 41.646711,  Lng: -87.480881),  Route carried "on" structure: US 12,  Year Built: 1987,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 8.17m (26.80ft),  Average Daily Traffic: 11,779 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,000 (year 2030),  Design Load: HS 20,  Features Intersected: LAKE GEORGE CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.483,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Navigation Control: Yes ( Vertical Clearance: 3.7m (12.1ft), Horizontal Clearance: 36.6m (120.1ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2020,  Critical Feature Inspection Date: November 2020,  Underwater Inspection Date: July 2021,  Deck Structure Type: Open Grating,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 311,  Location: 00.52 E US 20 (Lat: 41.639300,  Lng: -87.471328),  Route carried "on" structure: US 12,  Year Built: 1996,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 18,135 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 25,551 (year 2030),  Design Load: HS 20,  Features Intersected: INDIANA HARBOR CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.141,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 77.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2020,  Underwater Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 312,  Location: 01.01 E US 20 (Lat: 41.639181,  Lng: -87.461717),  Route carried "on" structure: US 12,  Year Built: 1994,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 24,672 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 34,763 (year 2029),  Design Load: HS 20,  Features Intersected: KENNEDY AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.930,  Lanes on structure: 6,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 313,  Location: 01.19 E US 20 (Lat: 41.639139,  Lng: -87.458761),  Route carried "on" structure: US 12,  Year Built: 1994,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 29.96m (98.29ft),  Average Daily Traffic: 19,735 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 34,763 (year 2030),  Design Load: HS 20,  Features Intersected: EJ&E RR,IHB RR, CAREY ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.219,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 4,  Length of Maximum Span: 43.9m (144.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: September 2020,  Other Special Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 462,  Location: 00.71 E I-65 (Lat: 40.605200,  Lng: -86.965400),  Route carried "on" structure: State highway 18,  Year Built: 1988,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 1,280 (year 2006),  Truck Traffic: 20%,  Average Future Daily Traffic: 2,125 (year 2030),  Design Load: HS 20,  Features Intersected: RAYMAN DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.040,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 33025,  Location: 00.19 E US 12 (Lat: 41.653861,  Lng: -87.475169),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1983,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 18.78m (61.61ft),  Average Daily Traffic: 1,239 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,747 (year 2030),  Design Load: HS 20+Mod,  Features Intersected: CONRAIL RR,  Facility Carried by Structure: RAMP B - WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.959,  Lanes on structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Toll: Toll bridge,  Owner: Private,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Segmental Box Girder,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 60.0m (196.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Other Special Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 3303,  Location: 01.66 E W JCT US 12 (Lat: 41.651239,  Lng: -87.453219),  Route carried "on" structure: State highway 912,  Year Built: 1980,  Status: Open,  Structure Length: 72.94m (239.30ft),  Average Daily Traffic: 35,922 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 50,614 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: CONRAIL RR, DICKEY RD, D
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.325,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Toll: Toll bridge,  Owner: Private,  Approaching Roadway Width: 32.9m (107.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 15,  Number Of Approach Spans: 14,  Length of Maximum Span: 44.5m (146.0ft),  Curb-To-Curb Width: 32.0m (105.0ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 33032,  Location: 01.34 W US 12 (Lat: 41.652881,  Lng: -87.443161),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 20.91m (68.60ft),  Average Daily Traffic: 5,195 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,320 (year 2030),  Design Load: HL 93,  Features Intersected: SR 912 EB/WB, RAMPS, RR,  Facility Carried by Structure: MICHIGAN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 12,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 50 months,  Inspection Date: September 2020,  Other Special Inspection Date: June 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 33035,  Location: 01.33 W US 12 (Lat: 41.651931,  Lng: -87.444089),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 3,780 (year 2004),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,325 (year 2030),  Design Load: HS 20,  Features Intersected: RAMP B,  Facility Carried by Structure: RAMP B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.258,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 33036,  Location: 01.33 W US 12 (Lat: 41.651911,  Lng: -87.444244),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1980,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 14,537 (year 2004),  Truck Traffic: 10%,  Average Future Daily Traffic: 20,483 (year 2030),  Design Load: HS 20,  Features Intersected: RAMP B,  Facility Carried by Structure: RAMP H
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.274,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 33037,  Location: 01.17 W US 12 (Lat: 41.652189,  Lng: -87.441994),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1980,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 25.30m (83.01ft),  Average Daily Traffic: 9,570 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,483 (year 2030),  Design Load: HS 20,  Features Intersected: ELEVATION CHANGE-UP RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.516,  Lanes on structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 29.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 33039,  Location: 00.32 W US 12 (Lat: 41.640611,  Lng: -87.431792),  Route carried "on" structure: State highway 912,  Year Built: 1980,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 4.50m (14.76ft),  Average Daily Traffic: 25,736 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 31,403 (year 2035),  Design Load: HS 20,  Features Intersected: GUTHRIE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.884,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 32.9m (107.9ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.7m (64.6ft),  Curb-To-Curb Width: 32.9m (107.9ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Inventory Rating: 59.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3304,  Location: 00.52 W SR 312 (Lat: 41.636331,  Lng: -87.432019),  Route carried "on" structure: State highway 912,  Year Built: 1970,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 28,365 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 39,967 (year 2030),  Design Load: HS 20,  Features Intersected: US 12 (INDSTR HWY) EB/WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.399,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 27.3m (89.6ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 26.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: November 2021,  Other Special Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3305,  Location: 00.09 W SR 312 (Lat: 41.630161,  Lng: -87.432175),  Route carried "on" structure: US 12,  Year Built: 1965,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 71,014 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 100,060 (year 2030),  Design Load: HS 20,  Features Intersected: N&S RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.293,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 31.4m (103.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 31.2m (102.4ft),  Out-to-Out Width: 33.0m (108.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3306,  Location: 01.27 N I-90 (Lat: 41.628850,  Lng: -87.432219),  Route carried "on" structure: US 12,  Year Built: 1965,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 8.14m (26.71ft),  Average Daily Traffic: 71,014 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 100,060 (year 2030),  Design Load: HS 20,  Features Intersected: SR 312, 2 RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.438,  Lanes on structure: 6,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 31.4m (103.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 31.3m (102.7ft),  Out-to-Out Width: 33.1m (108.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3308,  Location: 00.49 W I-90 (Lat: 41.617189,  Lng: -87.432069),  Route carried "on" structure: US 12,  Year Built: 1965,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 14.44m (47.38ft),  Average Daily Traffic: 39,160 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 99,395 (year 2030),  Design Load: HS 20,  Features Intersected: CN RR, GARY AV, DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.693,  Lanes on structure: 5,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Skew: 39 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 3,  Length of Maximum Span: 24.0m (78.7ft),  Curb-To-Curb Width: 26.0m (85.3ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 14.45m (47.41ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: April 2020,  Other Special Inspection Date: April 2020,  Bridge Improvement Cost: $2,600,000,  Roadway Improvement Cost: $261,000,  Total Project Cost: $2,861,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3309,  Location: 00.19 W I-90 (Lat: 41.613119,  Lng: -87.432250),  Route carried "on" structure: US 12,  Year Built: 1965,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 13.59m (44.59ft),  Average Daily Traffic: 81,933 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 115,443 (year 2032),  Design Load: HS 20,  Features Intersected: GRAND CALUMET RIV, 2 RDS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.176,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.5m (86.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 28.6m (93.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2020,  Underwater Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4619,  Location: 00.44 W US 20 (Lat: 41.617369,  Lng: -87.489136),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 72.18m (236.81ft),  Average Daily Traffic: 18,425 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20,  Features Intersected: GR CALUMET RIV, DR, 2 RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.557,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 33,  Length of Maximum Span: 52.7m (172.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2017,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 462,  Location: 00.44 W US 20 (Lat: 41.617439,  Lng: -87.489014),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 83.24m (273.10ft),  Average Daily Traffic: 18,425 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20,  Features Intersected: GR CALUMET RIV, DR, 2 RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.557,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 33,  Length of Maximum Span: 53.6m (175.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 83.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 73.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2019,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4621,  Location: 01.51 E SR 312 (Lat: 41.612681,  Lng: -87.480689),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 18,146 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20,  Features Intersected: US 20/SR 152/INDY BLV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.265,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 86.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4622,  Location: 01.51 E SR 312 (Lat: 41.612811,  Lng: -87.480689),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 18,146 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20,  Features Intersected: US 20/SR 152/INDY BLV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.265,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 86.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4623,  Location: 00.52 E US 20 (Lat: 41.610881,  Lng: -87.471153),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 15,083 (year 2011),  Truck Traffic: 14%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20+Mod,  Features Intersected: NIPSCO ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.102,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Excellent,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 98.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4624,  Location: 00.52 E US 20 (Lat: 41.611000,  Lng: -87.471153),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 15,083 (year 2011),  Truck Traffic: 14%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20+Mod,  Features Intersected: NIPSCO ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.102,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Excellent,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 98.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4625,  Location: 01.01 E US 20 (Lat: 41.610819,  Lng: -87.461450),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 9.51m (31.20ft),  Average Daily Traffic: 18,146 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20,  Features Intersected: CONRAIL RR, KENNEDY AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.891,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 72.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4626,  Location: 01.01 E US 20 (Lat: 41.610931,  Lng: -87.461450),  Route carried "on" structure: Interstate 90,  Year Built: 1956,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 9.51m (31.20ft),  Average Daily Traffic: 15,083 (year 2011),  Truck Traffic: 13%,  Average Future Daily Traffic: 41,903 (year 2031),  Design Load: HS 20,  Features Intersected: CONRAIL RR, KENNEDY AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.891,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Number Of Approach Spans: 2,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 72.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 7645,  Location: 00.86 W US 12 (Lat: 41.648669,  Lng: -87.437392),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1998,  Status: Open,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 1,053 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,483 (year 2030),  Design Load: HS 20,  Features Intersected: SR 912 CD, NS RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.015,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.8m (114.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Other Special Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 76451,  Location: 00.84 W US 12 (Lat: 41.648881,  Lng: -87.436469),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1998,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 1,053 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,483 (year 2030),  Design Load: HS 20,  Features Intersected: NS RR, ACCESS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.047,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.5m (119.8ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 29.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 76452,  Location: 00.83 W US 12 (Lat: 41.649450,  Lng: -87.435683),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1998,  Status: Open,  Structure Length: 9.87m (32.38ft),  Average Daily Traffic: 2,105 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,967 (year 2030),  Design Load: HS 20,  Features Intersected: IHB RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.063,  Lanes on structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 23.4m (76.8ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 52.0m (170.6ft),  Curb-To-Curb Width: 23.4m (76.8ft),  Out-to-Out Width: 24.3m (79.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 76453,  Location: 00.82 W US 12 (Lat: 41.648181,  Lng: -87.437181),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1998,  Status: Open,  Structure Length: 12.59m (41.31ft),  Average Daily Traffic: 1,053 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,483 (year 2030),  Design Load: HS 20,  Features Intersected: SR 912, SR 912 CD, NS RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.079,  Lanes on structure: 1,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 48.3m (158.5ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 76454,  Location: 00.81 W US 12 (Lat: 41.648561,  Lng: -87.436531),  Route carried "on" structure: Ramp State highway 912,  Year Built: 1998,  Status: Open,  Structure Length: 11.86m (38.91ft),  Average Daily Traffic: 1,053 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,483 (year 2030),  Design Load: HS 20,  Features Intersected: NS RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.095,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 45.2m (148.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 76522,  Location: 00.50 E US 20 (Lat: 41.629339,  Lng: -87.471161),  Route carried "on" structure: State highway 312,  Year Built: 2010,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 18,731 (year 2008),  Truck Traffic: 5%,  Average Future Daily Traffic: 20,600 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: INDIANA HARBOR CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.941,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Navigation Control: Yes ( Vertical Clearance: 2.3m (7.5ft), Horizontal Clearance: 14.0m (45.9ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 46.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2020,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8,  Location: 00.50 NE MICHIGAN ST (Lat: 41.655211,  Lng: -87.459189),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Posted for load,  Structure Length: 11.80m (38.71ft),  Average Daily Traffic: 21,854 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 26,933 (year 2038),  Design Load: HS 20,  Features Intersected: INDIANA HARBOR CANAL,  Facility Carried by Structure: DICKEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Navigation Control: Yes ( Vertical Clearance: 3.9m (12.8ft), Horizontal Clearance: 36.1m (118.4ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 50.0m (164.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2020,  Underwater Inspection Date: March 2017,  Deck Structure Type: Open Grating,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 80777,  Location: 00.89 E W JCT US 12 (Lat: 41.651269,  Lng: -87.465081),  Route carried "on" structure: State highway 912,  Year Built: 2020,  Status: Open,  Structure Length: 190.09m (623.65ft),  Average Daily Traffic: 10,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 50,614 (year 2026),  Design Load: HL 93,  Features Intersected: IND H. CANAL, RR, RD'S
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 4.892,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Toll: Toll bridge,  Owner: Private,  Approaching Roadway Width: 13.1m (43.0ft),  Navigation Control: Yes ( Vertical Clearance: 30.5m (100.1ft), Horizontal Clearance: 61.0m (200.1ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Segmental Box Girder,  Number Of Spans In Main Unit: 29,  Length of Maximum Span: 95.9m (314.6ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: December 2020,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4500114,  Location: 00.30 E. of INDY Blvd (Lat: 41.621219,  Lng: -87.471089),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 8,243 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,892 (year 2040),  Design Load: HS 20,  Features Intersected: INDIANA HARBOR CANAL,  Facility Carried by Structure: 151ST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 20 degrees,  Navigation Control: Yes ( Vertical Clearance: 4.6m (15.1ft), Horizontal Clearance: 19.5m (64.0ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 56.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.61m (18.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $58,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $88,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4500134,  Location: 00.30 N. of US 20 (Lat: 41.614150,  Lng: -87.461469),  Route carried "on" structure: City street ,  Year Built: 1980,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 8,688 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 10,708 (year 2040),  Design Load: HS 20,  Features Intersected: GRAND CALUMET RIVER,  Facility Carried by Structure: KENNEDY AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Navigation Control: Yes ( Vertical Clearance: 3.0m (9.8ft), Horizontal Clearance: 22.9m (75.1ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.0m (52.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Underwater Inspection Date: October 2017,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Discuss East Chicago, Indiana (IN) on our hugely popular Indiana forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.