Bridge Statistics for Minneapolis, Minnesota (MN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 748Number of bridges
  • 12,034ft / 3,668mTotal length
  • $43,447,988,000Total costs
  • 21,380,514Total average daily traffic
  • 715,072Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Minneapolis
  • No street view available for this location

New bridges in Minneapolis, MN - historical statistics
  • New bridges - historical statistics
  • 3Before 1900
  • 41900-1909
  • 351910-1919
  • 201920-1929
  • 41930-1939
  • 11940-1949
  • 2121960-1969
  • 981970-1979
  • 1521980-1989
  • 671990-1999
  • 752000-2009
  • 622010-2019
  • 152020-2022
Reconstructed bridges in Minneapolis, MN - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 141980-1989
  • 01990-1999
  • 62000-2009
  • 72010-2019
  • 12020-2022
Average Bridge Truck Traffic in Minneapolis, MN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.2%Excellent
  • 9.7%Very good
  • 33.4%Good
  • 33.4%Satisfactory
  • 18.8%Fair
  • 2.2%Poor
  • 0.3%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.2%Excellent
  • 11.4%Very good
  • 30.2%Good
  • 34.8%Satisfactory
  • 18.8%Fair
  • 1.5%Poor
  • 1.2%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.2%Excellent
  • 8.9%Very good
  • 35.1%Good
  • 22.8%Satisfactory
  • 26.5%Fair
  • 4.3%Poor
  • 0.3%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.2%Excellent
  • 38.9%Very good
  • 26.4%Good
  • 20.8%Satisfactory
  • 8.3%Fair
  • 1.4%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 5.9%Very good
  • 17.6%Good
  • 35.3%Satisfactory
  • 35.3%Fair
  • 5.9%Poor
Find on map >>   Show street view

Structure Number: 27798,  Location: AT THE JCT TH 394; 94 (Lat: 44.975892,  Lng: -93.287778),  Route carried "under" structure: Interstate 94,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 91,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94, RAMP; LYNDALE,  Facility Carried by Structure: CON 4555
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.0m (72.2ft)

Find on map >>   Show street view

Structure Number: 27799,  Location: 0.1 MI S OF JCT TH 394 (Lat: 44.971928,  Lng: -93.287453),  Route carried "under" structure: City street 312,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2005),  Features Intersected: Dunwoody Blvd,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.7m (61.4ft)

Find on map >>   Show street view

Structure Number: 27799L,  Location: 0.1 MI S OF JCT TH 394 (Lat: 44.972461,  Lng: -93.287156),  Route carried "under" structure: City street 312,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2005),  Features Intersected: Lyndale Avenue NB,  Facility Carried by Structure: CON 6593
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 27799R,  Location: 0.1 MI S OF JCT TH 394 (Lat: 44.972636,  Lng: -93.287811),  Route carried "under" structure: City street 312,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2005),  Features Intersected: Lyndale Avenue SB,  Facility Carried by Structure: CON 2224
Minimum Vertical Clearance: 4.66m (15.29ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>   Show street view

Structure Number: 27799R,  Location: 0.1 MI S OF JCT TH 394 (Lat: 44.972636,  Lng: -93.287811),  Route carried "under" structure: City street 1964,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 17,500 (year 1997),  Features Intersected: Lyndale Avenue SB,  Facility Carried by Structure: CON 2224
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>   Show street view

Structure Number: 27807,  Location: 1.3 MI S OF JCT TH 694 (Lat: 45.051156,  Lng: -93.285156),  Route carried "under" structure: Interstate 94,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 99,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 113
Minimum Vertical Clearance: 5.30m (17.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.7m (97.4ft)

Find on map >>   Show street view

Structure Number: 27808,  Location: 2.0 MI S OF JCT TH 694 (Lat: 45.043953,  Lng: -93.284653),  Route carried "under" structure: Ramp Interstate 5782,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 1994),  Features Intersected: I 94, BUS RAMP; ON RAMP,  Facility Carried by Structure: MSAS 263
Minimum Vertical Clearance: 5.40m (17.72ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>   Show street view

Structure Number: 27808,  Location: 2.0 MI S OF JCT TH 694 (Lat: 45.043953,  Lng: -93.284653),  Route carried "under" structure: Interstate 94,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 99,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94, BUS RAMP; ON RAMP,  Facility Carried by Structure: MSAS 263
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>   Show street view

Structure Number: 27808,  Location: 2.0 MI S OF JCT TH 694 (Lat: 45.043953,  Lng: -93.284653),  Route carried "under" structure: Ramp Interstate 5782,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 4,250 (year 1994),  Features Intersected: I 94, BUS RAMP; ON RAMP,  Facility Carried by Structure: MSAS 263
Minimum Vertical Clearance: 4.91m (16.11ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>   Show street view

Structure Number: 27812,  Location: 3.4 MI N OF JCT TH 12 (Lat: 45.023933,  Lng: -93.284517),  Route carried "under" structure: Interstate 94,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 111,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 169
Minimum Vertical Clearance: 7.13m (23.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.7m (110.6ft)

Find on map >>   Show street view

Structure Number: 27813,  Location: 2.7 MI N OF JCT TH 12 (Lat: 45.013111,  Lng: -93.282578),  Route carried "under" structure: Interstate 94,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 112,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: CSAH 153
Minimum Vertical Clearance: 8.02m (26.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.9m (104.7ft)

Find on map >>   Show street view

Structure Number: 27814,  Location: 2.2 MI N OF JCT TH 12 (Lat: 45.005883,  Lng: -93.282631),  Route carried "under" structure: Interstate 94,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 112,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 240
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.1m (105.3ft)

Find on map >>   Show street view

Structure Number: 27815,  Location: 1.8 MI N OF JCT TH 394 (Lat: 44.999172,  Lng: -93.282853),  Route carried "under" structure: Interstate 94,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 91,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94; US 952A,  Facility Carried by Structure: CSAH 81
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>   Show street view

Structure Number: 27815,  Location: 1.8 MI N OF JCT TH 394 (Lat: 44.999172,  Lng: -93.282853),  Route carried "under" structure: US 52,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 1996),  Truck Traffic: 5%,  Features Intersected: I 94; US 952A,  Facility Carried by Structure: CSAH 81
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>   Show street view

Structure Number: 27815,  Location: 1.8 MI N OF JCT TH 394 (Lat: 44.999172,  Lng: -93.282853),  Route carried "under" structure: US 52,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 1996),  Truck Traffic: 5%,  Features Intersected: I 94; US 952A,  Facility Carried by Structure: CSAH 81
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: City street 599,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 1979),  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: City street 209,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 4,300 (year 2005),  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: City street 194,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 4,500 (year 2005),  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: Other road ,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 1994),  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: Ramp US 4897,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 1994),  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 6.80m (22.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: Interstate 394,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 36,500 (year 2019),  Truck Traffic: 4%,  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816N,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.985894,  Lng: -93.279350),  Route carried "under" structure: City street 220,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 2,400 (year 2005),  Features Intersected: RR; STREETS TO I 94,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 5.85m (19.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: Ramp US 4897,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 1994),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: Ramp US 1812,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 1994),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 7.01m (23.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: Interstate 394,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 36,500 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: City street 209,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 4,300 (year 2005),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: City street 599,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 1979),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 6.16m (20.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: City street 194,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 4,500 (year 2005),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: Ramp US 1034,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 1994),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27816S,  Location: 0.3 MI SE OF JCT TH 94 (Lat: 44.986075,  Lng: -93.279983),  Route carried "under" structure: City street 220,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 2,400 (year 2005),  Features Intersected: I 94 ramp RR, streets,  Facility Carried by Structure: UNU 52
Minimum Vertical Clearance: 6.65m (21.82ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 27817,  Location: 1.6 MI N OF JCT TH 394 (Lat: 44.997842,  Lng: -93.283511),  Route carried "under" structure: US 52,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 20,000 (year 2006),  Truck Traffic: 5%,  Features Intersected: SB off ramp,  Facility Carried by Structure: CON 234
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.2m (151.6ft)

Find on map >>   Show street view

Structure Number: 27818,  Location: 1.4 MI N OF JCT TH 394 (Lat: 44.996264,  Lng: -93.282197),  Route carried "under" structure: US 52,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 9,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: NB on ramp,  Facility Carried by Structure: CON 4512
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.0m (108.3ft)

Find on map >>   Show street view

Structure Number: 27819,  Location: 2.9 MI S OF JCT TH 694 (Lat: 45.029400,  Lng: -93.286942),  Route carried "under" structure: Interstate 94,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 111,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: CSAH 152
Minimum Vertical Clearance: 7.13m (23.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 27821,  Location: 2.7 MI S OF JCT TH 694 (Lat: 45.032139,  Lng: -93.287422),  Route carried "under" structure: Interstate 94,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 111,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: RAILROAD
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 44.6m (146.3ft)

Find on map >>   Show street view

Structure Number: 27822,  Location: 1.5 MI S OF JCT I-94 (Lat: 44.946700,  Lng: -93.274700),  Route carried "under" structure: City street 366,  Year Built: 2021,  Structure Length: 0. m,  Average Daily Traffic: 9,900 (year 2019),  Features Intersected: E 31ST ST,  Facility Carried by Structure: I 35W NB
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 27831,  Location: 0.5 Mi west of Jct TH 94 (Lat: 44.972644,  Lng: -93.294503),  Route carried "under" structure: City street 312,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 14,100 (year 2005),  Features Intersected: Dunwoody Blvd,  Facility Carried by Structure: I 394
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 27834,  Location: AT THE W JCT TH 35; 94 (Lat: 44.965492,  Lng: -93.267936),  Route carried "under" structure: Interstate 94,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 72,645 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94 EB,  Facility Carried by Structure: I 35W
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Frame,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 27836,  Location: 0.5 MI W OF W JCT TH 35W (Lat: 44.965800,  Lng: -93.279342),  Route carried "under" structure: Interstate 94,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 154,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 159
Minimum Vertical Clearance: 4.66m (15.29ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 27837,  Location: 0.4 MI W OF W JCT TH 35W (Lat: 44.966250,  Lng: -93.277817),  Route carried "under" structure: Interstate 94,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 154,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 283
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 27838,  Location: 0.3 MI W OF W JCT TH 35W (Lat: 44.966564,  Lng: -93.276528),  Route carried "under" structure: Interstate 94,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 154,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 190
Minimum Vertical Clearance: 4.51m (14.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 2784,  Location: ATH THE JCT TH 65; 94 (Lat: 44.968033,  Lng: -93.269692),  Route carried "under" structure: Ramp Interstate 334,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 7,000 (year 1994),  Features Intersected: TH 65; RAMPS,  Facility Carried by Structure: MSAS 281
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 2784,  Location: ATH THE JCT TH 65; 94 (Lat: 44.968033,  Lng: -93.269692),  Route carried "under" structure: State highway 65,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 55 (year 2019),  Truck Traffic: 9%,  Features Intersected: TH 65; RAMPS,  Facility Carried by Structure: MSAS 281
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 2784,  Location: ATH THE JCT TH 65; 94 (Lat: 44.968033,  Lng: -93.269692),  Route carried "under" structure: Ramp State highway 2721,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 7,000 (year 1994),  Features Intersected: TH 65; RAMPS,  Facility Carried by Structure: MSAS 281
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 27841,  Location: 1.4 MI S OF JCT TH 94 (Lat: 44.948375,  Lng: -93.274894),  Route carried "under" structure: County highway 3,  Year Built: 2019,  Structure Length: 0. m,  Average Daily Traffic: 23,600 (year 2005),  Truck Traffic: 1%,  Features Intersected: E. LAKE ST
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 0.000,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 27844,  Location: 1.4 MI S OF JCT I 94 (Lat: 44.948394,  Lng: -93.274603),  Route carried "under" structure: County highway 3,  Year Built: 2021,  Structure Length: 0. m,  Average Daily Traffic: 20,200 (year 2011),  Truck Traffic: 1%,  Features Intersected: E. LAKE ST
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 27845,  Location: 1.3 MI S OF JCT I 94 (Lat: 44.948400,  Lng: -93.274800),  Route carried "under" structure: County highway 3,  Year Built: 2021,  Structure Length: 0. m,  Average Daily Traffic: 19,100 (year 2019),  Features Intersected: E LAKE ST,  Facility Carried by Structure: BUS RAPID TRANSIT
Minimum Vertical Clearance: 7.89m (25.89ft),  Kilometerpoint: 0.000,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 45.7m (149.9ft)

Find on map >>   Show street view

Structure Number: 27848,  Location: AT THE E JCT TH 94; 35W (Lat: 44.966139,  Lng: -93.255586),  Route carried "under" structure: Interstate 35W,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; SB on ramp,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 6.77m (22.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.1m (95.5ft)

Find on map >>   Show street view

Structure Number: 27848,  Location: AT THE E JCT TH 94; 35W (Lat: 44.966139,  Lng: -93.255586),  Route carried "under" structure: Ramp Interstate 1573,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 1994),  Features Intersected: I 35W; SB on ramp,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 4.63m (15.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.1m (95.5ft)

Find on map >>   Show street view

Structure Number: 27849,  Location: AT JCT TH 55; 35W (Lat: 44.967608,  Lng: -93.253783),  Route carried "under" structure: Interstate 35W,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; RAMPS,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 7.74m (25.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 27849,  Location: AT JCT TH 55; 35W (Lat: 44.967608,  Lng: -93.253783),  Route carried "under" structure: Ramp State highway 5483,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 8,300 (year 1994),  Features Intersected: I 35W; RAMPS,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 27849,  Location: AT JCT TH 55; 35W (Lat: 44.967608,  Lng: -93.253783),  Route carried "under" structure: Ramp State highway 576,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 10,200 (year 1994),  Features Intersected: I 35W; RAMPS,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 7.22m (23.69ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 27849,  Location: AT JCT TH 55; 35W (Lat: 44.967608,  Lng: -93.253783),  Route carried "under" structure: Ramp State highway 4341,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 1994),  Features Intersected: I 35W; RAMPS,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 27849,  Location: AT JCT TH 55; 35W (Lat: 44.967608,  Lng: -93.253783),  Route carried "under" structure: Ramp State highway 2373,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 8,300 (year 1994),  Features Intersected: I 35W; RAMPS,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>   Show street view

Structure Number: 2785,  Location: AT THE EAST JCT TH 94 (Lat: 44.966419,  Lng: -93.254844),  Route carried "under" structure: Ramp Interstate 1573,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 1994),  Features Intersected: I 35W; SB ON RAMP,  Facility Carried by Structure: CON 1923
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 2785,  Location: AT THE EAST JCT TH 94 (Lat: 44.966419,  Lng: -93.254844),  Route carried "under" structure: Interstate 35W,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; SB ON RAMP,  Facility Carried by Structure: CON 1923
Minimum Vertical Clearance: 7.44m (24.41ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 27851,  Location: 0.6 MI WEST OF JCT TH 55 (Lat: 44.965742,  Lng: -93.267656),  Route carried "under" structure: Ramp Interstate 4222,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 4,360 (year 1994),  Features Intersected: I 35W; I 94 WB,  Facility Carried by Structure: CSAH 35
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 27851,  Location: 0.6 MI WEST OF JCT TH 55 (Lat: 44.965742,  Lng: -93.267656),  Route carried "under" structure: Interstate 94,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 145,290 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; I 94 WB,  Facility Carried by Structure: CSAH 35
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 27851,  Location: 0.6 MI WEST OF JCT TH 55 (Lat: 44.965742,  Lng: -93.267656),  Route carried "under" structure: Interstate 35W,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 95,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; I 94 WB,  Facility Carried by Structure: CSAH 35
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 27851,  Location: 0.6 MI WEST OF JCT TH 55 (Lat: 44.965742,  Lng: -93.267656),  Route carried "under" structure: Ramp Interstate 2792,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 3,700 (year 1994),  Features Intersected: I 35W; I 94 WB,  Facility Carried by Structure: CSAH 35
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 27851,  Location: 0.6 MI WEST OF JCT TH 55 (Lat: 44.965742,  Lng: -93.267656),  Route carried "under" structure: Ramp Interstate 334,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 6,100 (year 1994),  Features Intersected: I 35W; I 94 WB,  Facility Carried by Structure: CSAH 35
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 27852,  Location: 0.5 MI WEST OF JCT TH 55 (Lat: 44.965714,  Lng: -93.265097),  Route carried "under" structure: Interstate 35W,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W, I 94; ramp,  Facility Carried by Structure: CSAH 33
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27852,  Location: 0.5 MI WEST OF JCT TH 55 (Lat: 44.965714,  Lng: -93.265097),  Route carried "under" structure: Interstate 94,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W, I 94; ramp,  Facility Carried by Structure: CSAH 33
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27852,  Location: 0.5 MI WEST OF JCT TH 55 (Lat: 44.965714,  Lng: -93.265097),  Route carried "under" structure: Interstate 94,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 78,500 (year 2004),  Truck Traffic: 4%,  Features Intersected: I 35W, I 94; ramp,  Facility Carried by Structure: CSAH 33
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27852,  Location: 0.5 MI WEST OF JCT TH 55 (Lat: 44.965714,  Lng: -93.265097),  Route carried "under" structure: Ramp Interstate 2792,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 3,700 (year 1994),  Features Intersected: I 35W, I 94; ramp,  Facility Carried by Structure: CSAH 33
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27852,  Location: 0.5 MI WEST OF JCT TH 55 (Lat: 44.965714,  Lng: -93.265097),  Route carried "under" structure: Ramp Interstate 3332,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 1 (year 2022),  Features Intersected: I 35W, I 94; ramp,  Facility Carried by Structure: CSAH 33
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.000,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27853,  Location: 0.4 MI WEST OF JCT TH 55 (Lat: 44.965686,  Lng: -93.262567),  Route carried "under" structure: Interstate 94,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; I 94,  Facility Carried by Structure: MSAS 165
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 27853,  Location: 0.4 MI WEST OF JCT TH 55 (Lat: 44.965686,  Lng: -93.262567),  Route carried "under" structure: Interstate 35W,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; I 94,  Facility Carried by Structure: MSAS 165
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 27853,  Location: 0.4 MI WEST OF JCT TH 55 (Lat: 44.965686,  Lng: -93.262567),  Route carried "under" structure: Interstate 94,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 78,500 (year 2004),  Truck Traffic: 4%,  Features Intersected: I 35W; I 94,  Facility Carried by Structure: MSAS 165
Minimum Vertical Clearance: 4.48m (14.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 27854,  Location: 0.3 MI WEST OF JCT TH 55 (Lat: 44.965881,  Lng: -93.258178),  Route carried "under" structure: Interstate 94,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 124,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W, I 94; WB ON RAMP,  Facility Carried by Structure: MSAS 213
Minimum Vertical Clearance: 4.51m (14.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27854,  Location: 0.3 MI WEST OF JCT TH 55 (Lat: 44.965881,  Lng: -93.258178),  Route carried "under" structure: Ramp Interstate 4217,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 7,300 (year 1994),  Features Intersected: I 35W, I 94; WB ON RAMP,  Facility Carried by Structure: MSAS 213
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27854,  Location: 0.3 MI WEST OF JCT TH 55 (Lat: 44.965881,  Lng: -93.258178),  Route carried "under" structure: Interstate 35W,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W, I 94; WB ON RAMP,  Facility Carried by Structure: MSAS 213
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27854,  Location: 0.3 MI WEST OF JCT TH 55 (Lat: 44.965881,  Lng: -93.258178),  Route carried "under" structure: Interstate 94,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W, I 94; WB ON RAMP,  Facility Carried by Structure: MSAS 213
Minimum Vertical Clearance: 4.48m (14.70ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27854,  Location: 0.3 MI WEST OF JCT TH 55 (Lat: 44.965881,  Lng: -93.258178),  Route carried "under" structure: Ramp Interstate 4557,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 6,266 (year 2019),  Truck Traffic: 1%,  Features Intersected: I 35W, I 94; WB ON RAMP,  Facility Carried by Structure: MSAS 213
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 27855,  Location: AT THE JCT TH 55; 94 (Lat: 44.966094,  Lng: -93.252286),  Route carried "under" structure: Ramp Interstate 3930,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 8,300 (year 1994),  Features Intersected: TH 55; RAMPS,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.3m (135.5ft)

Find on map >>   Show street view

Structure Number: 27855,  Location: AT THE JCT TH 55; 94 (Lat: 44.966094,  Lng: -93.252286),  Route carried "under" structure: Ramp Interstate 1923,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 7,300 (year 1994),  Features Intersected: TH 55; RAMPS,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 6.68m (21.92ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.3m (135.5ft)

Find on map >>   Show street view

Structure Number: 27855,  Location: AT THE JCT TH 55; 94 (Lat: 44.966094,  Lng: -93.252286),  Route carried "under" structure: Ramp Interstate 4293,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 11,970 (year 1994),  Features Intersected: TH 55; RAMPS,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 5.40m (17.72ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.3m (135.5ft)

Find on map >>   Show street view

Structure Number: 27855,  Location: AT THE JCT TH 55; 94 (Lat: 44.966094,  Lng: -93.252286),  Route carried "under" structure: Ramp Interstate 3021,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 1994),  Features Intersected: TH 55; RAMPS,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 6.19m (20.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.3m (135.5ft)

Find on map >>   Show street view

Structure Number: 27855,  Location: AT THE JCT TH 55; 94 (Lat: 44.966094,  Lng: -93.252286),  Route carried "under" structure: State highway 55,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 64,090 (year 2019),  Truck Traffic: 4%,  Features Intersected: TH 55; RAMPS,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.3m (135.5ft)

Find on map >>   Show street view

Structure Number: 27856,  Location: 1.6 MI NE OF JCT TH 55 (Lat: 44.967081,  Lng: -93.220539),  Route carried "under" structure: Interstate 94,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 154,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94; RAMPS,  Facility Carried by Structure: CSAH 5
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Find on map >>   Show street view

Structure Number: 27856,  Location: 1.6 MI NE OF JCT TH 55 (Lat: 44.967081,  Lng: -93.220539),  Route carried "under" structure: Ramp Interstate 2781,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 1994),  Features Intersected: I 94; RAMPS,  Facility Carried by Structure: CSAH 5
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Find on map >>   Show street view

Structure Number: 27856,  Location: 1.6 MI NE OF JCT TH 55 (Lat: 44.967081,  Lng: -93.220539),  Route carried "under" structure: Ramp Interstate 4861,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 1994),  Features Intersected: I 94; RAMPS,  Facility Carried by Structure: CSAH 5
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.8m (120.7ft)

Find on map >>   Show street view

Structure Number: 27857,  Location: 0.1 MI S OF JCT TH 55 (Lat: 44.965467,  Lng: -93.251678),  Route carried "under" structure: Ramp State highway 1923,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 7,300 (year 1994),  Features Intersected: I 94 WB ON RAMP,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Frame,  Length of Maximum Span: 12.7m (41.7ft)

Find on map >>   Show street view

Structure Number: 27859,  Location: 0.1 MI E OF JCT TH 55 (Lat: 44.966269,  Lng: -93.249764),  Route carried "under" structure: City street 2375,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 250 (year 1974),  Features Intersected: CP RAIL; CITY ST,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.5m (90.2ft)

Find on map >>   Show street view

Structure Number: 2786,  Location: 1.5 MI E OF JCT TH 55 (Lat: 44.966983,  Lng: -93.223908),  Route carried "under" structure: Interstate 94,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 154,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94; RAMPS,  Facility Carried by Structure: CON 2781
Minimum Vertical Clearance: 5.67m (18.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.9m (167.0ft)

Find on map >>   Show street view

Structure Number: 2786,  Location: 1.5 MI E OF JCT TH 55 (Lat: 44.966983,  Lng: -93.223908),  Route carried "under" structure: Ramp Interstate 4934,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 1994),  Features Intersected: I 94; RAMPS,  Facility Carried by Structure: CON 2781
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.9m (167.0ft)

Find on map >>   Show street view

Structure Number: 2786,  Location: 1.5 MI E OF JCT TH 55 (Lat: 44.966983,  Lng: -93.223908),  Route carried "under" structure: Ramp Interstate 4934,  Year Built: 1994,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 1994),  Features Intersected: I 94; RAMPS,  Facility Carried by Structure: CON 2781
Minimum Vertical Clearance: 5.85m (19.19ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.9m (167.0ft)

Find on map >>   Show street view

Structure Number: 27861,  Location: 0.1 MI E OF JCT TH 55 (Lat: 44.966606,  Lng: -93.249772),  Route carried "under" structure: City street 2375,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 250 (year 1974),  Features Intersected: CP RAIL; CITY ST,  Facility Carried by Structure: CON 2017
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 27863,  Location: 0.2 MI E OF JCT TH 55 (Lat: 44.965789,  Lng: -93.247261),  Route carried "under" structure: County highway 152,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 17,400 (year 2005),  Features Intersected: Cedar Ave,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 4.76m (15.62ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 27865,  Location: 0.4 MI SE OF JCT TH 55 (Lat: 44.964639,  Lng: -93.244186),  Route carried "under" structure: Interstate 94,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 160,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 94,  Facility Carried by Structure: MSAS 282
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 27873,  Location: 0.2 MI NE OF E JCT TH 94 (Lat: 44.967136,  Lng: -93.254092),  Route carried "under" structure: Ramp Interstate 576,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 10,200 (year 1994),  Features Intersected: I 35W; NB OFF RAMP,  Facility Carried by Structure: CON 5483
Minimum Vertical Clearance: 4.79m (15.72ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 27873,  Location: 0.2 MI NE OF E JCT TH 94 (Lat: 44.967136,  Lng: -93.254092),  Route carried "under" structure: Interstate 35W,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 114,000 (year 2019),  Truck Traffic: 4%,  Features Intersected: I 35W; NB OFF RAMP,  Facility Carried by Structure: CON 5483
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 27874,  Location: 0.2 MI N OF E JCT TH 94 (Lat: 44.967747,  Lng: -93.252936),  Route carried "under" structure: Ramp Interstate 576,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 10,200 (year 1994),  Features Intersected: I 35W NB off ramp,  Facility Carried by Structure: CON 2672
Minimum Vertical Clearance: 4.51m (14.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.6m (77.4ft)

Find on map >>   Show street view

Structure Number: 27875,  Location: AT JCT TH 55 OVER 35W (Lat: 44.968178,  Lng: -93.253539),  Route carried "under" structure: Ramp State highway 576,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 10,200 (year 1994),  Features Intersected: I 35W; RAMPS,  Facility Carried by Structure: MN 55
Minimum Vertical Clearance: 6.25m (20.51ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.3m (86.3ft)

Discuss Minneapolis, Minnesota (MN) on our hugely popular Minnesota forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.