  • National Bridge Inventory (NBI) Statistics
  • 125Number of bridges
  • 1,168ft / 356mTotal length
  • $7,319,000Total costs
  • 7,577,175Total average daily traffic
  • 365,736Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Southfield
  • No street view available for this location

New bridges in Southfield, MI - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 21930-1939
  • 21950-1959
  • 611960-1969
  • 81970-1979
  • 401980-1989
  • 41990-1999
  • 42000-2009
  • 22010-2019
Reconstructed bridges in Southfield, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 41970-1979
  • 51980-1989
  • 171990-1999
  • 112000-2009
Average Bridge Daily Traffic in Southfield, MI
Average Bridge Truck Traffic in Southfield, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.7%Excellent
  • 6.8%Very good
  • 43.8%Good
  • 37.0%Satisfactory
  • 9.6%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 8.2%Excellent
  • 8.2%Very good
  • 39.7%Good
  • 27.4%Satisfactory
  • 16.4%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 9.6%Very good
  • 45.2%Good
  • 30.1%Satisfactory
  • 15.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 3.7%Excellent
  • 37.0%Very good
  • 14.8%Good
  • 14.8%Satisfactory
  • 14.8%Fair
  • 11.1%Poor
  • 3.7%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 40.0%Very good
  • 20.0%Good
  • 20.0%Satisfactory
  • 20.0%Poor
Find on map >>   Show street view

Structure Number: 7913,  Location: IN SOUTHFIELD (Lat: 42.487325,  Lng: -83.278589),  Route carried "on" structure: Interstate 696,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 56,238 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 62,138 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.407,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 71,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7914,  Location: IN SOUTHFIELD (Lat: 42.487414,  Lng: -83.278364),  Route carried "on" structure: Interstate 696,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 56,238 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 62,138 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.406,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 71,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7917,  Location: IN SOUTHFIELD (Lat: 42.487211,  Lng: -83.281792),  Route carried "on" structure: Ramp Interstate 696,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 4.84m (15.88ft),  Average Daily Traffic: 17,000 (year 1982),  Truck Traffic: 5%,  Average Future Daily Traffic: 17,000 (year 1977),  Design Load: HS 20+Mod,  Features Intersected: M-10 SB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.146,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.4m (83.3ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7918,  Location: IN SOUTHFIELD (Lat: 42.485467,  Lng: -83.266747),  Route carried "on" structure: Interstate 696,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 9.23m (30.28ft),  Average Daily Traffic: 122,300 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 118,082 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: M-10
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.423,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 71,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 36 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 47.8m (156.8ft),  Curb-To-Curb Width: 36.2m (118.8ft),  Out-to-Out Width: 38.1m (125.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7919,  Location: CITY OF SOUTHFIELD (Lat: 42.485519,  Lng: -83.261303),  Route carried "on" structure: County highway 2059,  Year Built: 1984,  Status: Open,  Structure Length: 7.35m (24.11ft),  Average Daily Traffic: 15,000 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,000 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: LAHSER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.703,  Lanes on structure: 5,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 32.5m (106.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 792,  Location: 0.4 MI EAST OF LASHER (Lat: 42.486600,  Lng: -83.252581),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 11.28m (37.01ft),  Average Daily Traffic: 1,500 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: 11 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 57.9m (190.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7921,  Location: IN SOUTHFIELD (Lat: 42.487192,  Lng: -83.241186),  Route carried "on" structure: City street 2059,  Year Built: 1985,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 15,000 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,250 (year 2008),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: EVERGREEN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.828,  Lanes on structure: 7,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 32.5m (106.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7926,  Location: IN SOUTHFIELD (Lat: 42.487681,  Lng: -83.212522),  Route carried "on" structure: City street 2059,  Year Built: 1987,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 8.71m (28.58ft),  Average Daily Traffic: 450 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 450 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: E B 11 MILE SER RO
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.473,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 45.6m (149.6ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7927,  Location: CITY OF SOUTHFIELD (Lat: 42.480997,  Lng: -83.207081),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 1,500 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: LINCOLN DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.972,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.0m (91.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7928,  Location: CITY OF SOUTHFIELD (Lat: 42.477461,  Lng: -83.203150),  Route carried "on" structure: Ramp County highway 2059,  Year Built: 1987,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 3,000 (year 1984),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,000 (year 1977),  Design Load: HS 20,  Features Intersected: I-696,  Facility Carried by Structure: U-TURN W.OF GRNFLD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.023,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7929,  Location: 1/4 MI.N. OF 10 MILE (Lat: 42.476939,  Lng: -83.201872),  Route carried "on" structure: County highway 2059,  Year Built: 1987,  Status: Open,  Structure Length: 4.92m (16.14ft),  Average Daily Traffic: 50,100 (year 1995),  Truck Traffic: 3%,  Average Future Daily Traffic: 59,000 (year 2010),  Design Load: HS 20,  Features Intersected: I-696,  Facility Carried by Structure: GREENFIELD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.571,  Lanes on structure: 6,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.6m (80.7ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 35.6m (116.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 793,  Location: IN ROYAL OAK TOWNSHIP (Lat: 42.477008,  Lng: -83.200589),  Route carried "on" structure: Ramp County highway 2059,  Year Built: 1987,  Status: Open,  Structure Length: 4.74m (15.55ft),  Average Daily Traffic: 4,000 (year 1984),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,000 (year 1977),  Design Load: HS 20,  Features Intersected: I-696,  Facility Carried by Structure: U-TURN E.OF GRNFLD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.019,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.7m (77.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7945,  Location: 0.2 MI EAST OF LASHER (Lat: 42.485561,  Lng: -83.257800),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 1,500 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: CORPORATE DR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.343,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.9m (121.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7946,  Location: SOUTHFIELD,W/CENT PK BLVD (Lat: 42.486842,  Lng: -83.249425),  Route carried "on" structure: City street 2059,  Year Built: 1987,  Status: Open,  Structure Length: 5.34m (17.52ft),  Average Daily Traffic: 2,400 (year 1993),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 20,  Features Intersected: I-696,  Facility Carried by Structure: HARVARD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.029,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.3m (96.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7947,  Location: IN SOUTHFIELD (Lat: 42.487111,  Lng: -83.244664),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 1,500 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: CENTRAL PARK BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.793,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 25.5m (83.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7948,  Location: 0.1 M W OF EVERGREEN (Lat: 42.487336,  Lng: -83.242878),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 1,500 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: MEADOWLARK U EAST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.024,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7949,  Location: E OF EVERGREEN (Lat: 42.487428,  Lng: -83.239533),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 5,800 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,800 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: RED RIVER AVE U-T
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.026,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 15.3m (50.2ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 795,  Location: IN LATHRUP VILLAGE (Lat: 42.487592,  Lng: -83.230514),  Route carried "on" structure: County highway 2059,  Year Built: 1987,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 1,500 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: I-696,  Facility Carried by Structure: SANTA BARBARA U EA
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.440,  Lanes on structure: 1,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7994,  Location: IN SOUTHFIELD (Lat: 42.451286,  Lng: -83.219856),  Route carried "on" structure: City street ,  Year Built: 1963,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 1,500 (year 1984),  Truck Traffic: 3%,  Average Future Daily Traffic: 320 (year 1977),  Design Load: HS 20,  Features Intersected: M-39,  Facility Carried by Structure: CORNELL RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.045,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.32m (10.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $151,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $77,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8147,  Location: BET 9 AND 10 MILE RDS (Lat: 42.467650,  Lng: -83.260525),  Route carried "on" structure: County highway 2059,  Year Built: 1983,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 17,080 (year 1994),  Average Future Daily Traffic: 20,100 (year 2014),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: LAHSER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.717,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 24.5m (80.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 86.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8164,  Location: BET INKSTER AND BEECH (Lat: 42.471347,  Lng: -83.303883),  Route carried "on" structure: County highway 2059,  Year Built: 1984,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 10,737 (year 1990),  Average Future Daily Traffic: 12,600 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: PEBBLE CREEK,  Facility Carried by Structure: 10 MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.834,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 26.6m (87.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8165,  Location: BET TELEGRAPH AND BEECH (Lat: 42.471728,  Lng: -83.288572),  Route carried "on" structure: County highway 2059,  Year Built: 1995,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 16,418 (year 1995),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,000 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: 10 MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.093,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8166,  Location: WEST OF NORTHWESTERN (Lat: 42.472725,  Lng: -83.247922),  Route carried "on" structure: County highway 2059,  Year Built: 1982,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,997 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 40,000 (year 2017),  Design Load: HS 20+Mod,  Features Intersected: CLAIRE DRAIN,  Facility Carried by Structure: 10 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.437,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.4m (17.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 32.2m (105.6ft)

Condition: Channel: Poor,  Culverts: Good,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8169,  Location: BET TELEGRAPH AND LAHSER (Lat: 42.501183,  Lng: -83.278728),  Route carried "on" structure: County highway 2059,  Year Built: 1972,  Status: Posted for load,  Structure Length: 3.51m (11.52ft),  Average Daily Traffic: 19,870 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 26,800 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: 12 MILE RD (WEST)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.551,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 446,  Subroute: 80),  Owner: County Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 42.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 817,  Location: BET TELEGRAPH AND LAHSER (Lat: 42.501272,  Lng: -83.273736),  Route carried "on" structure: County highway 2059,  Year Built: 1972,  Status: Posted for load,  Structure Length: 3.51m (11.52ft),  Average Daily Traffic: 19,870 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 26,800 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: 12 MILE RD (EAST)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.961,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 446,  Subroute: 80),  Owner: County Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 42.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 829,  Location: W OF BEECH RD (Lat: 42.456844,  Lng: -83.305878),  Route carried "on" structure: City street 2059,  Year Built: 1930,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 7,976 (year 2011),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,215 (year 2013),  Design Load: HS 25 or greater,  Features Intersected: RIVER ROUGE,  Facility Carried by Structure: NINE MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.964,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.4m (99.7ft),  Curb or Sidewalk Widths: Left: 4.3m (14.1ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8291,  Location: IN SOUTHFIELD (Lat: 42.457708,  Lng: -83.267397),  Route carried "on" structure: City street 2059,  Year Built: 2019,  Status: Open,  Structure Length: 3.78m (12.40ft),  Average Daily Traffic: 13,604 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 14,735 (year 2038),  Design Load: Greater than HL93,  Features Intersected: EVANS BRANCH OF ROUGE RI,  Facility Carried by Structure: NINE MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.130,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.7m (120.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.15m (30.02ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $3,184,000,  Roadway Improvement Cost: $572,000,  Total Project Cost: $4,943,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8292,  Location: IN SOUTHFIELD (Lat: 42.485817,  Lng: -83.308603),  Route carried "on" structure: City street 2059,  Year Built: 1972,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 10,483 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 10,798 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: PEBBLE CREEK,  Facility Carried by Structure: ELEVEN MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.662,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.6m (24.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 8294,  Location: IN SOUTHFIELD (Lat: 42.447817,  Lng: -83.297650),  Route carried "on" structure: City street 2059,  Year Built: 2012,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 6,637 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 7,300 (year 2032),  Design Load: Greater than HL93,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: BEECH RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.613,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 79.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 60.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8295,  Location: IN SOUTHFIELD (Lat: 42.467228,  Lng: -83.298575),  Route carried "on" structure: City street 2059,  Year Built: 1952,  Status: Open,  Structure Length: 1.67m (5.48ft),  Average Daily Traffic: 5,629 (year 2011),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,798 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: BEECH RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.770,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.1m (52.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.67m (5.48ft),  Designated Inspection Frequency: Every 18 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $47,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $73,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8296,  Location: IN SOUTHFIELD (Lat: 42.484381,  Lng: -83.288867),  Route carried "on" structure: City street 2059,  Year Built: 1992,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 19,439 (year 2010),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,022 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: PERNICK CREEK,  Facility Carried by Structure: FRANKLIN RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.350,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.1m (0.3ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 8297,  Location: E OF TELEGRAPH RD (Lat: 42.488836,  Lng: -83.276528),  Route carried "on" structure: City street 2059,  Year Built: 2004,  Status: Open,  Structure Length: 3.15m (10.33ft),  Average Daily Traffic: 6,216 (year 2011),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,403 (year 2013),  Design Load: HS 25 or greater,  Features Intersected: RIVER ROUGE,  Facility Carried by Structure: ELEVEN MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.201,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8299,  Location: IN SOUTHFIELD (Lat: 42.479153,  Lng: -83.284422),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 9,592 (year 2010),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,880 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: CIVIC CENTER DRIVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.084,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.4m (126.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 24.7m (81.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $25,000,  Total Project Cost: $30,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 83,  Location: IN SOUTHFIELD (Lat: 42.444028,  Lng: -83.268750),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 2,205 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,271 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: EVANS BRANCH ROUGE RIVER,  Facility Carried by Structure: BERG ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8302,  Location: IN SOUTHFIELD (Lat: 42.508597,  Lng: -83.236025),  Route carried "on" structure: City street ,  Year Built: 1925,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 934 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 962 (year 2013),  Design Load: HS 25 or greater,  Features Intersected: NORTH CREEK,  Facility Carried by Structure: HICKORY LEAF RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.515,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.8m (22.3ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Excellent,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8304,  Location: IN SOUTHFIELD (Lat: 42.466536,  Lng: -83.252444),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 370 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 381 (year 2013),  Design Load: HS 20+Mod,  Features Intersected: EVANSBRANCHOFROUGE,  Facility Carried by Structure: TAMARACK TRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.185,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Serious,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 8305,  Location: N OF 8 MILE RD (Lat: 42.443422,  Lng: -83.285197),  Route carried "on" structure: City street ,  Year Built: 1972,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 1,248 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,286 (year 2013),  Design Load: HS 25 or greater,  Features Intersected: RIVER ROUGE,  Facility Carried by Structure: BRIDGE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.058,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.5m (67.3ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Fair,  Channel: Good,  Inventory Rating: 66.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Other