Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for St. Louis, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 84Number of bridges
  • 610ft / 186mTotal length
  • $3,048,000Total costs
  • 240,117Total average daily traffic
  • 16,536Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for St. Louis
  • No street view available for this location

New bridges in St. Louis, MI - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 21920-1929
  • 51930-1939
  • 11950-1959
  • 231960-1969
  • 111970-1979
  • 191980-1989
  • 41990-1999
  • 82000-2009
  • 82010-2019
  • 22020-2022
Reconstructed bridges in St. Louis, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
  • 41990-1999
  • 32000-2009
Average Bridge Daily Traffic in St. Louis, MI
Average Bridge Truck Traffic in St. Louis, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.7%Excellent
  • 5.0%Very good
  • 35.0%Good
  • 33.3%Satisfactory
  • 21.7%Fair
  • 3.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.3%Excellent
  • 8.3%Very good
  • 18.3%Good
  • 28.3%Satisfactory
  • 33.3%Fair
  • 8.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 15.0%Very good
  • 31.7%Good
  • 30.0%Satisfactory
  • 16.7%Fair
  • 5.0%Poor
  • 1.7%Critical
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 15.2%Very good
  • 33.3%Good
  • 31.8%Satisfactory
  • 13.6%Fair
  • 6.1%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 17.6%Excellent
  • 23.5%Very good
  • 17.6%Good
  • 23.5%Satisfactory
  • 17.6%Fair
Find on map >>   Show street view

Structure Number: 477,  Location: AT TURNER RD (Lat: 44.143561,  Lng: -83.585597),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 60 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 75 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: WHITNEY DRAIN,  Facility Carried by Structure: ROAD 107
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.027,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.6m (57.7ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 582,  Location: 2.7 MI E OF MUNGER (Lat: 43.522161,  Lng: -83.725008),  Route carried "on" structure: State highway 138,  Year Built: 1968,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 1,305 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,775 (year 2018),  Design Load: HS 20,  Features Intersected: QUANICASSEE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.659,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 78.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 583,  Location: 3.5 MI E OF MUNGER (Lat: 43.522308,  Lng: -83.708833),  Route carried "on" structure: State highway 138,  Year Built: 1969,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,305 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,775 (year 2018),  Design Load: HS 20,  Features Intersected: CONSTANT DURUSSELL DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.966,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 81.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1001,  Location: 3 MI S OF WATERVLIET (Lat: 42.145069,  Lng: -86.242450),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Posted for load,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 32 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 80 (year 2027),  Design Load: H 20,  Features Intersected: MILL CREEK,  Facility Carried by Structure: HILL AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.454,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Wood or Timber,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.8m (5.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 12.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 8.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1002,  Location: 3 MI SE OF STEVENSVILLE (Lat: 41.979100,  Lng: -86.498825),  Route carried "on" structure: County highway ,  Year Built: 1970,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 274 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 400 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: HICKORY CREEK,  Facility Carried by Structure: MARRS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.271,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.7m (18.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1003,  Location: 2 MI NE OF BENTON HARBOR (Lat: 42.144625,  Lng: -86.408058),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 235 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 500 (year 2027),  Design Load: H 15,  Features Intersected: BLUE CREEK,  Facility Carried by Structure: EUCLID AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.056,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 20.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 12.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: High priority of corrective action,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 1005,  Location: 4 MI SW OF NILES (Lat: 41.763772,  Lng: -86.274600),  Route carried "on" structure: County highway ,  Year Built: 1934,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 639 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,500 (year 2027),  Features Intersected: MEI LI CREEK,  Facility Carried by Structure: COPP ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.391,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 20.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 12.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 1007,  Location: 2 MI E OF UNION PIER (Lat: 41.827694,  Lng: -86.655814),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Open,  Structure Length: 2.25m (7.38ft),  Average Daily Traffic: 280 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 450 (year 2027),  Design Load: HS 20,  Features Intersected: GALIEN RIVER,  Facility Carried by Structure: ELM VALLEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.012,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1008,  Location: 2 MI S OF SAWYER (Lat: 41.856928,  Lng: -86.590208),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 1.85m (6.07ft),  Average Daily Traffic: 391 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 500 (year 2027),  Design Load: HS 20,  Features Intersected: GALIEN RIVER,  Facility Carried by Structure: FLYNN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.478,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1017,  Location: 1.0 MI S OF STEVENSVILLE (Lat: 41.996036,  Lng: -86.514264),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 1,139 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,000 (year 2027),  Design Load: HS 20,  Features Intersected: HICKORY CREEK,  Facility Carried by Structure: HOLDEN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.180,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1104,  Location: BETHEL TWP SEC 29-32 (Lat: 41.825500,  Lng: -85.155300),  Route carried "on" structure: County highway 1220,  Year Built: 2006,  Status: Open,  Structure Length: 1.50m (4.92ft),  Average Daily Traffic: 372 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 501 (year 2026),  Design Load: HS 20,  Features Intersected: PRAIRIE RIVER,  Facility Carried by Structure: CRANSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.135,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.8m (45.3ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3092,  Location: 0.5 MI S OF ST LOUIS (Lat: 43.390406,  Lng: -84.621369),  Route carried "on" structure: US 127,  Year Built: 1960,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 8,293 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,739 (year 2018),  Design Load: HS 20,  Features Intersected: MID MICH RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 32.053,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2022,  Other Special Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3093,  Location: 0.5 MI S OF ST LOUIS (Lat: 43.390197,  Lng: -84.621581),  Route carried "on" structure: US 127,  Year Built: 1960,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 8,293 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,739 (year 2018),  Design Load: HS 20,  Features Intersected: MID MICHIGAN RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 32.051,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2022,  Other Special Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3098,  Location: 2.0 MI S OF ST LOUIS (Lat: 43.378811,  Lng: -84.602725),  Route carried "on" structure: US 127,  Year Built: 1961,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.35m (14.27ft),  Average Daily Traffic: 9,181 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,448 (year 2018),  Design Load: HS 20,  Features Intersected: US-127 BR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.060,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.1m (62.7ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 87.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3099,  Location: 2.0 MI S OF ST LOUIS (Lat: 43.378817,  Lng: -84.603167),  Route carried "on" structure: US 127,  Year Built: 1961,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.47m (14.67ft),  Average Daily Traffic: 9,181 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,448 (year 2018),  Design Load: HS 20,  Features Intersected: US-127 BR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.089,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.3m (63.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 31,  Location: 1.5 MI S OF ST LOUIS (Lat: 43.382108,  Lng: -84.607106),  Route carried "on" structure: US 127,  Year Built: 1961,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 15,400 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 18,800 (year 2035),  Design Load: HS 20,  Features Intersected: US-127 BR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.575,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 94.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3101,  Location: 1.5 MI S OF ST LOUIS (Lat: 43.381789,  Lng: -84.607111),  Route carried "on" structure: US 127,  Year Built: 1961,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 15,400 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 18,800 (year 2035),  Design Load: HS 20,  Features Intersected: US-127 BR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.553,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 94.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3102,  Location: NE LTS OF ALMA (Lat: 43.393239,  Lng: -84.626250),  Route carried "on" structure: US 127,  Year Built: 1961,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 8,293 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,739 (year 2018),  Design Load: HS 20,  Features Intersected: MICHIGAN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.558,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Other Special Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3103,  Location: NE LTS OF ALMA (Lat: 43.393078,  Lng: -84.626528),  Route carried "on" structure: US 127,  Year Built: 1961,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 8,293 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,739 (year 2018),  Design Load: HS 20,  Features Intersected: MICHIGAN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.563,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: August 2020,  Other Special Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3112,  Location: IN ST LOUIS (Lat: 43.407828,  Lng: -84.618739),  Route carried "on" structure: State highway 46,  Year Built: 1930,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 9,548 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 12,851 (year 2018),  Design Load: HS 15,  Features Intersected: PINE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.346,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Underwater Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 313,  Location: 3.5 MI E OF ST LOUIS (Lat: 43.408006,  Lng: -84.537078),  Route carried "on" structure: State highway 46,  Year Built: 1960,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 5,784 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,919 (year 2018),  Design Load: HS 20,  Features Intersected: BUSH CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 24.957,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 49,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3172,  Location: SEC 4-5 BETHANY TWP (Lat: 43.453347,  Lng: -84.568133),  Route carried "on" structure: County highway 2967,  Year Built: 1984,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 1,135 (year 2003),  Average Future Daily Traffic: 1,535 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: PINE RIVER,  Facility Carried by Structure: BAGLEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 17.998,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 3183,  Location: SEC 27-34 BETHANY TWP (Lat: 43.393506,  Lng: -84.543083),  Route carried "on" structure: County highway ,  Year Built: 1936,  Status: Posted for load,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 92 (year 2004),  Average Future Daily Traffic: 118 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: BUSH CREEK DRAIN,  Facility Carried by Structure: JACKSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.836,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 1.22m (4.00ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $110,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $165,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 3236,  Location: SEC 25 PINE RIVER TWP (Lat: 43.400550,  Lng: -84.615400),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 1,058 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,572 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: PINE RIVER,  Facility Carried by Structure: CHEESMAN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.757,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.8m (74.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3255,  Location: CITY OF ST LOUIS (Lat: 43.393486,  Lng: -84.625847),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 1.64m (5.38ft),  Average Daily Traffic: 5,068 (year 2001),  Truck Traffic: 8%,  Average Future Daily Traffic: 9,153 (year 2020),  Design Load: HS 20,  Features Intersected: HORSE CREEK,  Facility Carried by Structure: MICHIGAN AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.681,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3257,  Location: CITY OF ST LOUIS (Lat: 43.410947,  Lng: -84.607167),  Route carried "on" structure: City street ,  Year Built: 1955,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 1,000 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,800 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: PINE RIVER,  Facility Carried by Structure: MAIN STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.860,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5503,  Location: 2.7 MI S OF M-34 (Lat: 41.819361,  Lng: -84.235147),  Route carried "on" structure: State highway 156,  Year Built: 1925,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 1,791 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,318 (year 2018),  Design Load: H 15,  Features Intersected: BEAR CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.960,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5832,  Location: CONWAY TWP SEC 10-11 (Lat: 42.743272,  Lng: -84.077511),  Route carried "on" structure: County highway 4715,  Year Built: 2007,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,909 (year 2013),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,060 (year 2043),  Design Load: HS 25 or greater,  Features Intersected: CONWAY COHOCTAH DRAIN,  Facility Carried by Structure: MOHRLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.999,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 93.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 56.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 584,  Location: HARTLAND TWP SEC 6 (Lat: 42.690956,  Lng: -83.781428),  Route carried "on" structure: County highway ,  Year Built: 1938,  Year Reconstructed: 2000,  Status: Posted for load,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 670 (year 2015),  Average Future Daily Traffic: 700 (year 2035),  Design Load: HS 20,  Features Intersected: NORTH ORE CREEK,  Facility Carried by Structure: PARSHALLVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.341,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5842,  Location: SEC 20 GREEN OAK TWP (Lat: 42.471342,  Lng: -83.756436),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 5,259 (year 2013),  Average Future Daily Traffic: 11,950 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: HURON RIVER,  Facility Carried by Structure: WHITMORE LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.326,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.1m (72.5ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Good,  Channel: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7683,  Location: 0.9 MI W OF BLACKMERE RD (Lat: 43.143972,  Lng: -85.966236),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 2.56m (8.40ft),  Average Daily Traffic: 68 (year 2004),  Average Future Daily Traffic: 108 (year 2024),  Design Load: HS 20,  Features Intersected: CROCKERY CREEK,  Facility Carried by Structure: PATTERSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.116,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 36.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10008,  Location: @I-94 BL (GRATIOT) (Lat: 42.907322,  Lng: -82.505475),  Route carried "on" structure: Interstate 94,  Year Built: 2006,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 7,908 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 20,330 (year 2026),  Design Load: HS 25 or greater,  Features Intersected: I-94 BL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.532,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 96,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 88.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10011,  Location: 3.3 MI NE OF M-25 (Lat: 42.951800,  Lng: -82.501922),  Route carried "on" structure: County highway 2012,  Year Built: 2003,  Status: Open,  Structure Length: 9.11m (29.89ft),  Average Daily Traffic: 11,200 (year 1993),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,200 (year 2023),  Design Load: HS 25 or greater,  Features Intersected: I-94,  Facility Carried by Structure: RANGE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.167,  Lanes on structure: 3,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.3m (109.3ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10014,  Location: @ I-69 (Lat: 42.975694,  Lng: -82.478500),  Route carried "on" structure: Interstate 69,  Year Built: 2013,  Status: Open,  Structure Length: 9.94m (32.61ft),  Average Daily Traffic: 13,295 (year 2012),  Truck Traffic: 12%,  Average Future Daily Traffic: 15,788 (year 2033),  Design Load: Greater than HL93,  Features Intersected: I-94
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 43.285,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 96,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 49.7m (163.1ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10024,  Location: HARSENS ISLAND-CLAY TWP (Lat: 42.557653,  Lng: -82.641833),  Route carried "on" structure: County highway 7765,  Year Built: 1987,  Status: Posted for load,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 580 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 860 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: MAYBURY CUT CANAL,  Facility Carried by Structure: BATES HIGHWAY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.488,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Navigation Control: Yes ( Vertical Clearance: 0.3m (1.0ft), Horizontal Clearance: 7.4m (24.3ft)),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.3m (27.2ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Poor,  Channel: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Underwater Inspection Date: October 2017,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 10031,  Location: SEC 17-20 COTTRELLVILLE (Lat: 42.681167,  Lng: -82.583789),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,500 (year 1994),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,000 (year 2014),  Design Load: H 20,  Features Intersected: BEAUBIEN CREEK DRAIN,  Facility Carried by Structure: SHEA ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.665,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10032,  Location: PC 191-318 COTTRELLVILLE (Lat: 42.684778,  Lng: -82.530933),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,100 (year 1994),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,200 (year 2014),  Design Load: HS 20+Mod,  Features Intersected: MARINE CITY DREDGE CUT,  Facility Carried by Structure: BROADBRIDGE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.863,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 60.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 55.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10033,  Location: SEC 10 COTTRELLVILLE TWP (Lat: 42.707931,  Lng: -82.533617),  Route carried "on" structure: County highway 7771,  Year Built: 1922,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 2,800 (year 1994),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,450 (year 2014),  Design Load: HS 20,  Features Intersected: MARINE CITY DREDGE CUT,  Facility Carried by Structure: CHARTIER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.417,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 75.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 9.14m (29.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $450,000,  Roadway Improvement Cost: $150,000,  Total Project Cost: $600,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10045,  Location: SEC. 24 COLUMBUS TWP. (Lat: 42.856347,  Lng: -82.622211),  Route carried "on" structure: County highway 7746,  Year Built: 2021,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 4,250 (year 1994),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,600 (year 2014),  Design Load: Greater than HL93,  Features Intersected: UNNAMED CREEK,  Facility Carried by Structure: GRATIOT ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.440,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Channel: Good,  Culverts: Excellent,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.18m (16.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Roadway Improvement Cost: $40,000,  Total Project Cost: $41,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss St. Louis, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.