Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Grand Rapids, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 269Number of bridges
  • 4,331ft / 1,320mTotal length
  • $3,922,000Total costs
  • 6,381,085Total average daily traffic
  • 408,489Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Grand Rapids
  • No street view available for this location

New bridges in Grand Rapids, MI - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 21900-1909
  • 41920-1929
  • 31930-1939
  • 41940-1949
  • 51950-1959
  • 1531960-1969
  • 121970-1979
  • 121980-1989
  • 251990-1999
  • 332000-2009
  • 102010-2019
  • 52020-2022
Reconstructed bridges in Grand Rapids, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 61970-1979
  • 81980-1989
  • 181990-1999
  • 232000-2009
  • 52010-2019
  • 12020-2022
Average Bridge Daily Traffic in Grand Rapids, MI
Average Bridge Truck Traffic in Grand Rapids, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.3%Excellent
  • 4.6%Very good
  • 38.2%Good
  • 37.5%Satisfactory
  • 14.5%Fair
  • 0.7%Poor
  • 1.3%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.3%Excellent
  • 17.1%Very good
  • 26.3%Good
  • 23.0%Satisfactory
  • 28.9%Fair
  • 1.3%Poor
  • 0.7%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 3.3%Excellent
  • 5.3%Very good
  • 42.8%Good
  • 34.2%Satisfactory
  • 13.2%Fair
  • 1.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 31.1%Very good
  • 33.3%Good
  • 33.3%Satisfactory
  • 2.2%Poor
Find on map >>   Show street view

Structure Number: 52,  Location: 3.4 MI E OF SHINGLETON (Lat: 46.346908,  Lng: -86.400872),  Route carried "on" structure: State highway 28,  Year Built: 1947,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 1,973 (year 2007),  Truck Traffic: 13%,  Average Future Daily Traffic: 3,096 (year 2018),  Design Load: HS 20,  Features Intersected: STAR CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.231,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 113,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 478,  Location: 0.4 MI W OF US-23 (Lat: 44.143611,  Lng: -83.575647),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 130 (year 1998),  Average Future Daily Traffic: 70 (year 1977),  Design Load: HS 20,  Features Intersected: WHITNEY DRAIN,  Facility Carried by Structure: NOBLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.227,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.04m (6.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $183,000,  Roadway Improvement Cost: $18,000,  Total Project Cost: $215,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 479,  Location: CITY OF STANDISH (Lat: 43.988022,  Lng: -83.957022),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 1,000 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,500 (year 2024),  Design Load: HS 20,  Features Intersected: MIDDLE BR PINE RIVER,  Facility Carried by Structure: GROVE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.077,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 52.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 481,  Location: 6.5 MI W OF NESTORIA (Lat: 46.578839,  Lng: -88.412819),  Route carried "on" structure: US 41,  Year Built: 1947,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 2,624 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 4,613 (year 2018),  Design Load: HS 20,  Features Intersected: HICKEY CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.763,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 118,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 482,  Location: 1.4 MI S OF ALBERTA (Lat: 46.625164,  Lng: -88.470222),  Route carried "on" structure: US 41,  Year Built: 1947,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 3,585 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 3,800 (year 2020),  Design Load: HS 20,  Features Intersected: STURGEON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 33.035,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 118,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 483,  Location: 4.0 MI S OF L'ANSE (Lat: 46.703442,  Lng: -88.442303),  Route carried "on" structure: US 41,  Year Built: 1951,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 3,585 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,177 (year 2018),  Design Load: HS 20,  Features Intersected: TAYLOR CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 42.491,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 118,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.22m (4.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $23,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 495,  Location: 3.5 MI W OF NESTORIA (Lat: 46.575417,  Lng: -88.340717),  Route carried "on" structure: US 41,  Year Built: 1947,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 2,624 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 4,970 (year 2018),  Design Load: HS 20,  Features Intersected: TIOGA RIVER BURIED
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.206,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 118,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 519,  Location: 6 MI NE OF COVINGTON (Lat: 46.570903,  Lng: -88.407642),  Route carried "on" structure: County highway ,  Year Built: 2020,  Status: Open,  Structure Length: 1.41m (4.63ft),  Average Daily Traffic: 68 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 108 (year 2040),  Design Load: Greater than HL93,  Features Intersected: HICKEY CREEK,  Facility Carried by Structure: OLD M-28
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.875,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.98m (6.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $550,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $675,000 ( Estimate for 2015),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 521,  Location: 0.25 MI S OF HERMAN (Lat: 46.663236,  Lng: -88.365561),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 37 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 100 (year 2035),  Design Load: HS 20,  Features Intersected: DAULTS CREEK,  Facility Carried by Structure: HERMAN-NESTORIA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.213,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1284,  Location: 3.0 MI W OF JACKSON COL (Lat: 42.267611,  Lng: -84.776042),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 10.97m (35.99ft),  Average Daily Traffic: 900 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,225 (year 2000),  Design Load: H 15,  Features Intersected: I-94,  Facility Carried by Structure: 27 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.110,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.3m (112.5ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1394,  Location: ONE BLK WEST OF M-99 (Lat: 42.245608,  Lng: -84.754572),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 5,775 (year 2009),  Truck Traffic: 12%,  Average Future Daily Traffic: 7,775 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: KALAMAZOO RIVER,  Facility Carried by Structure: N CLINTON STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.853,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 76.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.59m (8.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $340,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $390,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4707,  Location: IN GRAND RAPIDS (LEONARD (Lat: 42.984697,  Lng: -85.671808),  Route carried "on" structure: Business US 131,  Year Built: 1979,  Status: Open,  Structure Length: 18.59m (60.99ft),  Average Daily Traffic: 21,583 (year 2014),  Truck Traffic: 2%,  Average Future Daily Traffic: 24,820 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: GRAND RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.544,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 28.9m (94.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2020,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4708,  Location: IN GRAND RAPIDS (Lat: 42.970447,  Lng: -85.668625),  Route carried "on" structure: City street 2001,  Year Built: 2007,  Status: Open,  Structure Length: 2.58m (8.46ft),  Truck Traffic: 3%,  Average Future Daily Traffic: 54,000 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: US-131 BR (DIVISION AVE),  Facility Carried by Structure: MICHIGAN ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.149,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.6m (80.7ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 28.8m (94.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 67.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4723,  Location: IN GRAND RAPIDS (Lat: 43.021097,  Lng: -85.661569),  Route carried "on" structure: Interstate 96,  Year Built: 1962,  Year Reconstructed: 1978,  Status: Open,  Structure Length: 23.43m (76.87ft),  Average Daily Traffic: 23,263 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 27,265 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.810,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 76.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4724,  Location: IN GRAND RAPIDS (Lat: 43.021353,  Lng: -85.661442),  Route carried "on" structure: Interstate 96,  Year Built: 1962,  Year Reconstructed: 1978,  Status: Open,  Structure Length: 23.43m (76.87ft),  Average Daily Traffic: 23,263 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 27,625 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.656,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 23.45m (76.94ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: June 2020,  Bridge Improvement Cost: $544,000,  Roadway Improvement Cost: $27,000,  Total Project Cost: $320,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4726,  Location: 0.3 MI E OF M-44 (Lat: 42.968847,  Lng: -85.585650),  Route carried "on" structure: Interstate 96,  Year Built: 1961,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 42,937 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 60,700 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: GRAND RAPIDS EASTERN RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.300,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 14 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 65.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4727,  Location: 0.3 MI E OF M-44 (Lat: 42.968750,  Lng: -85.585158),  Route carried "on" structure: Interstate 96,  Year Built: 1961,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 42,937 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 60,700 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: GRAND RAPIDS EASTERN RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.139,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 14 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.8m (84.6ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 65.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4728,  Location: IN GRAND RAPIDS (Lat: 43.021075,  Lng: -85.660100),  Route carried "on" structure: Interstate 96,  Year Built: 1962,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 23,263 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 27,625 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: MONROE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.108,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4729,  Location: IN GRAND RAPIDS (Lat: 43.021339,  Lng: -85.659975),  Route carried "on" structure: Interstate 96,  Year Built: 1962,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 23,263 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 27,625 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: MONROE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.950,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 473,  Location: IN GRAND RAPIDS (Lat: 43.021006,  Lng: -85.654714),  Route carried "on" structure: Interstate 96,  Year Built: 1962,  Status: Open,  Structure Length: 4.56m (14.96ft),  Average Daily Traffic: 23,263 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 27,265 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: COIT AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.547,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.7m (64.6ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4731,  Location: IN GRAND RAPIDS (Lat: 43.021261,  Lng: -85.654639),  Route carried "on" structure: Interstate 96,  Year Built: 1962,  Status: Open,  Structure Length: 4.56m (14.96ft),  Average Daily Traffic: 23,263 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 27,625 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: COIT AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.387,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.7m (64.6ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4732,  Location: IN GRAND RAPIDS (Lat: 43.021164,  Lng: -85.647400),  Route carried "on" structure: City street ,  Year Built: 1960,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 7.73m (25.36ft),  Average Daily Traffic: 836 (year 2013),  Average Future Daily Traffic: 961 (year 2033),  Design Load: H 20,  Features Intersected: I-96,  Facility Carried by Structure: CHENEY AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.876,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.5m (70.5ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4733,  Location: IN GRAND RAPIDS (Lat: 43.019433,  Lng: -85.636150),  Route carried "on" structure: Ramp State highway 44,  Year Built: 1999,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 32,442 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 41,732 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: I-96
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.986,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.1m (98.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4734,  Location: 2.8 MI E & S OF US-131 (Lat: 43.015275,  Lng: -85.615058),  Route carried "on" structure: County highway 2001,  Year Built: 1961,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 8,696 (year 1995),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,706 (year 2015),  Design Load: H 20,  Features Intersected: I-96,  Facility Carried by Structure: DEAN LAKE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.794,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4735,  Location: 3.0 MI E & S OF US-131 (Lat: 43.013269,  Lng: -85.610378),  Route carried "on" structure: County highway 2001,  Year Built: 1961,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 11.95m (39.21ft),  Average Daily Traffic: 6,569 (year 1995),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,864 (year 2015),  Design Load: H 20,  Features Intersected: I-96,  Facility Carried by Structure: 3 MI RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.315,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 11.95m (39.21ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $323,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $195,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4736,  Location: 4.1 MI E & S OF US-131 (Lat: 42.998817,  Lng: -85.604617),  Route carried "on" structure: County highway 2001,  Year Built: 1961,  Status: Open,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 5,609 (year 1996),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,130 (year 2016),  Design Load: HS 20,  Features Intersected: I-96,  Facility Carried by Structure: KNAPP STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.369,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4737,  Location: IN GRAND RAPIDS (Lat: 42.984372,  Lng: -85.604758),  Route carried "on" structure: County highway 2001,  Year Built: 1961,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 7.53m (24.70ft),  Average Daily Traffic: 13,779 (year 1994),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,846 (year 2014),  Design Load: H 20,  Features Intersected: I-96,  Facility Carried by Structure: LEONARD ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.074,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.3m (79.7ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $62,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4739,  Location: IN GRAND RAPIDS (Lat: 42.972586,  Lng: -85.590708),  Route carried "on" structure: State highway 44,  Year Built: 1961,  Status: Open,  Structure Length: 9.60m (31.50ft),  Average Daily Traffic: 42,978 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 59,425 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: I-96
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.989,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.7m (100.7ft),  Curb-To-Curb Width: 21.7m (71.2ft),  Out-to-Out Width: 22.2m (72.8ft)

Condition: Deck: Serious,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $1,718,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 474,  Location: 0.2 MI E OF GRAND RAPIDS (Lat: 42.962942,  Lng: -85.581133),  Route carried "on" structure: State highway 21,  Year Built: 1961,  Status: Open,  Structure Length: 6.67m (21.88ft),  Average Daily Traffic: 5,413 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,780 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: I-96 EB RAMP
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.340,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.7m (77.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,052,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4741,  Location: 0.3 MI E OF GRAND RAPIDS (Lat: 42.963033,  Lng: -85.578953),  Route carried "on" structure: State highway 21,  Year Built: 1961,  Status: Open,  Structure Length: 9.48m (31.10ft),  Average Daily Traffic: 5,413 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,802 (year 2015),  Design Load: HS 20+Mod,  Features Intersected: I-96 & M-21
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.476,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 341,  Subroute: 99),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.3m (106.0ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,495,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4742,  Location: 0.4 MI E OF GRAND RAPIDS (Lat: 42.961964,  Lng: -85.577450),  Route carried "on" structure: State highway 21,  Year Built: 1961,  Status: Open,  Structure Length: 10.67m (35.01ft),  Average Daily Traffic: 28,460 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 21,200 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: I-96 & M-21
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.308,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.9m (117.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,757,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4764,  Location: IN GRAND RAPIDS (Lat: 42.972436,  Lng: -85.673758),  Route carried "on" structure: Interstate 196,  Year Built: 1964,  Year Reconstructed: 2019,  Status: Temporarily open,  Structure Length: 69.42m (227.76ft),  Average Daily Traffic: 41,000 (year 2014),  Truck Traffic: 10%,  Average Future Daily Traffic: 47,150 (year 2034),  Design Load: HS 20+Mod,  Features Intersected: GD R,I-296,SCRB,TRN,MONR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.886,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 26,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 15 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Critical Feature Inspection Date: July 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4765,  Location: IN GRAND RAPIDS (Lat: 42.972919,  Lng: -85.676069),  Route carried "on" structure: Ramp Interstate 196,  Year Built: 1964,  Status: Open,  Structure Length: 11.34m (37.20ft),  Average Daily Traffic: 11,000 (year 1988),  Truck Traffic: 8%,  Average Future Daily Traffic: 12,650 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: SCRIBNER AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.074,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4766,  Location: IN GRAND RAPIDS (Lat: 42.970872,  Lng: -85.678247),  Route carried "on" structure: Ramp Interstate 296,  Year Built: 1964,  Status: Open,  Structure Length: 19.81m (64.99ft),  Average Daily Traffic: 6,810 (year 1982),  Truck Traffic: 8%,  Average Future Daily Traffic: 7,832 (year 2002),  Design Load: HS 20+Mod,  Features Intersected: I-196 EB,  Facility Carried by Structure: I-196 WB FR US-131
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.278,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 6.8m (22.3ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 15 months,  Inspection Date: November 2020,  Critical Feature Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4767,  Location: IN GRAND RAPIDS (Lat: 42.972689,  Lng: -85.676456),  Route carried "on" structure: Ramp Interstate 196,  Year Built: 1964,  Status: Open,  Structure Length: 13.56m (44.49ft),  Average Daily Traffic: 6,810 (year 1982),  Truck Traffic: 8%,  Average Future Daily Traffic: 7,832 (year 2002),  Design Load: HS 20+Mod,  Features Intersected: I-196 EB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.066,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 15 months,  Inspection Date: November 2020,  Critical Feature Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4768,  Location: IN GRAND RAPIDS (Lat: 42.973308,  Lng: -85.679731),  Route carried "on" structure: Ramp Interstate 296,  Year Built: 1964,  Status: Open,  Structure Length: 23.78m (78.02ft),  Average Daily Traffic: 9,700 (year 1988),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,155 (year 2008),  Design Load: HS 20+Mod,  Features Intersected: BROADWAY&TURNER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.745,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.0m,  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 91.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4769,  Location: IN GRAND RAPIDS (Lat: 42.972236,  Lng: -85.673783),  Route carried "on" structure: Interstate 196,  Year Built: 1964,  Year Reconstructed: 2021,  Status: Open,  Structure Length: 18.47m (60.60ft),  Average Daily Traffic: 45,200 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 50,438 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.136,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 40,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.6m (57.7ft)

Condition: Deck: Excellent,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 18.48m (60.63ft),  Designated Inspection Frequency: Every 11 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: July 2020,  Bridge Improvement Cost: $1,005,000,  Roadway Improvement Cost: $64,000,  Total Project Cost: $751,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Grand Rapids, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.