Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Rockford, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 279Number of bridges
  • 2,851ft / 869mTotal length
  • $29,013,000Total costs
  • 2,631,685Total average daily traffic
  • 378,691Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rockford
  • No street view available for this location

New bridges in Rockford, IL - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 91900-1909
  • 41910-1919
  • 61920-1929
  • 111930-1939
  • 31940-1949
  • 251950-1959
  • 771960-1969
  • 241970-1979
  • 421980-1989
  • 191990-1999
  • 272000-2009
  • 282010-2019
  • 32020-2022
Reconstructed bridges in Rockford, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31950-1959
  • 21960-1969
  • 21970-1979
  • 51980-1989
  • 171990-1999
  • 162000-2009
  • 22010-2019
Average Bridge Daily Traffic in Rockford, IL
Average Bridge Truck Traffic in Rockford, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.0%Excellent
  • 8.1%Very good
  • 22.2%Good
  • 43.0%Satisfactory
  • 16.3%Fair
  • 5.9%Poor
  • 1.5%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.9%Excellent
  • 20.4%Very good
  • 19.7%Good
  • 30.7%Satisfactory
  • 14.6%Fair
  • 8.8%Poor
  • 2.9%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.9%Excellent
  • 24.1%Very good
  • 35.0%Good
  • 22.6%Satisfactory
  • 12.4%Fair
  • 2.2%Poor
  • 0.7%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 3.3%Excellent
  • 20.7%Very good
  • 25.0%Good
  • 33.7%Satisfactory
  • 13.0%Fair
  • 4.3%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 13.1%Very good
  • 31.3%Good
  • 32.3%Satisfactory
  • 22.2%Fair
  • 1.0%Poor
Find on map >>   Show street view

Structure Number: 101019,  Location: 1.4 MI N WHITMAN ST (Lat: 42.288664,  Lng: -89.061097),  Route carried "on" structure: State highway 251,  Year Built: 2012,  Status: Open,  Structure Length: 8.03m (26.35ft),  Average Daily Traffic: 31,800 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 37,800 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: SPRING CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 192.875,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 37.8m (124.0ft),  Skew: 34 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.5m (70.5ft),  Curb-To-Curb Width: 35.3m (115.8ft),  Out-to-Out Width: 37.2m (122.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010195,  Location: .5 MI E OF IL 2 (Lat: 42.219361,  Lng: -89.099411),  Route carried "on" structure: US 20,  Year Built: 2014,  Status: Open,  Structure Length: 12.43m (40.78ft),  Average Daily Traffic: 30,900 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 18,158 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: W CHANNEL ROCK RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 150.148,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Navigation Control: Yes ( Vertical Clearance: 4.9m (16.1ft), Horizontal Clearance: 61.0m (200.1ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 61.0m (200.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010196,  Location: .5 MI E OF ILL 2 (Lat: 42.219361,  Lng: -89.099000),  Route carried "on" structure: US 20,  Year Built: 2015,  Status: Open,  Structure Length: 12.43m (40.78ft),  Average Daily Traffic: 30,900 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 18,158 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: W CHANNEL ROCK RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 150.180,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 61.0m (200.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010197,  Location: .7 MI E OF ILL 2 (Lat: 42.219372,  Lng: -89.096133),  Route carried "on" structure: US 20,  Year Built: 2014,  Status: Open,  Structure Length: 13.32m (43.70ft),  Average Daily Traffic: 30,900 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 18,158 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: E CHANNEL ROCK RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 150.405,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Navigation Control: Yes ( Vertical Clearance: 5.2m (17.1ft), Horizontal Clearance: 65.5m (214.9ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 66.6m (218.5ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010198,  Location: .7 MI E OF ILL 2 (Lat: 42.219369,  Lng: -89.095928),  Route carried "on" structure: US 20,  Year Built: 2015,  Status: Open,  Structure Length: 13.32m (43.70ft),  Average Daily Traffic: 30,900 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 18,158 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: E CHANNEL ROCK RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 150.421,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Navigation Control: Yes ( Vertical Clearance: 5.2m (17.1ft), Horizontal Clearance: 64.3m (211.0ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 66.6m (218.5ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1011079,  Location: .39 MI W MERIDIAN RD (Lat: 42.279811,  Lng: -89.180394),  Route carried "on" structure: Business US 20,  Year Built: 2009,  Status: Open,  Structure Length: 0.86m (2.82ft),  Average Daily Traffic: 5,300 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,800 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.746,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Excellent,  Culverts: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 1012,  Location: .35 MI. S HARRISON (Lat: 42.233239,  Lng: -89.072250),  Route carried "on" structure: State highway 251,  Year Built: 1964,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 16,900 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 22,900 (year 2040),  Design Load: HS 20,  Features Intersected: S.E. DRAINAGE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 184.635,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.3m (10.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 1012006,  Location: .2 MI E MERIDIAN RD (Lat: 42.265831,  Lng: -89.170061),  Route carried "on" structure: US 20,  Year Built: 1964,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 15,500 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 24,600 (year 2040),  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 141.457,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 10 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.4m (14.4ft),  Curb-To-Curb Width: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 1012007,  Location: 1.3 MI E MERIDIAN RD (Lat: 42.258061,  Lng: -89.149089),  Route carried "on" structure: US 20,  Year Built: 1964,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 15,500 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 22,700 (year 2040),  Features Intersected: KENT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 143.501,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.7m (15.4ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 1012008,  Location: .5 MI W OF ILL 2 (Lat: 42.219619,  Lng: -89.116514),  Route carried "on" structure: US 20,  Year Built: 1964,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 20,900 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 31,500 (year 2040),  Design Load: H 20,  Features Intersected: FULLERS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 148.635,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 11 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.7m (15.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 1012019,  Location: .4 MI. N. AUBURN ST. (Lat: 42.294803,  Lng: -89.145244),  Route carried "on" structure: Other road ,  Year Built: 1960,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 8,650 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 13,800 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: SPRINGFIELD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.544,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 1012036,  Location: .2 MI E MERIDIAN RD (Lat: 42.330958,  Lng: -89.170606),  Route carried "on" structure: State highway 70,  Year Built: 1991,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 4,550 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,800 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.173,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 18.3m (60.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 1012037,  Location: 1.9 MI N TRASK BR RD (Lat: 42.362261,  Lng: -89.185111),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 300 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TUNNISON CREEK,  Facility Carried by Structure: HARRISON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.966,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1012038,  Location: .75 MI W ALPINE RD (Lat: 42.266136,  Lng: -89.043539),  Route carried "on" structure: Business US 20,  Year Built: 1993,  Status: Open,  Structure Length: 1.66m (5.45ft),  Average Daily Traffic: 18,000 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 34,300 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: KEITH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.639,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 13 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018
Find on map >>   Show street view

Structure Number: 1012042,  Location: .1 MI N SPRING CR RD (Lat: 42.289825,  Lng: -89.060408),  Route carried "on" structure: State highway 251,  Year Built: 2002,  Status: Open,  Structure Length: 1.08m (3.54ft),  Average Daily Traffic: 31,800 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 37,800 (year 2040),  Design Load: HS 20,  Features Intersected: SPRING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 192.987,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 1012046,  Location: .4 MI E. MERIDIAN RD (Lat: 42.329581,  Lng: -89.166719),  Route carried "on" structure: State highway 70,  Year Built: 2003,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 4,550 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,900 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.819,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 101205,  Location: 1.5 MI S US20 BYPASS (Lat: 42.201183,  Lng: -89.072411),  Route carried "on" structure: State highway 251,  Year Built: 2019,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 7,800 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 181.078,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 43.9m (144.0ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 43.9m (144.0ft),  Out-to-Out Width: 81.1m (266.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 1013003,  Location: 0.5 MI E PIERPONT (Lat: 42.265269,  Lng: -89.126153),  Route carried "on" structure: Other road ,  Year Built: 1955,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 2,450 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,000 (year 2040),  Design Load: H 20,  Features Intersected: CN RR,  Facility Carried by Structure: CUNNINGHAM ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.205,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.7m (51.5ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Serious,  Substructure: Good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013012,  Location: 0.5 MI S CUNNINGHAM (Lat: 42.256917,  Lng: -89.173458),  Route carried "on" structure: County highway ,  Year Built: 1954,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 2,800 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,200 (year 2040),  Design Load: HS 20,  Features Intersected: CN RR,  Facility Carried by Structure: MERIDIAN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.418,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013023,  Location: 0.1 MI N AUBURN ST (Lat: 42.290864,  Lng: -89.116103),  Route carried "on" structure: Other road ,  Year Built: 1966,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 3.15m (10.33ft),  Average Daily Traffic: 8,350 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 9,500 (year 2040),  Design Load: HS 20,  Features Intersected: N FORK KENT CREEK,  Facility Carried by Structure: CENTRAL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.876,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 1013027,  Location: 0.1 MI S CUNNINGHAM (Lat: 42.258314,  Lng: -89.155119),  Route carried "on" structure: County highway ,  Year Built: 1928,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 325 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 500 (year 2040),  Design Load: H 15,  Features Intersected: SO FORK KENT CREEK,  Facility Carried by Structure: CENTERVILLE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1013069,  Location: 1.1MI W OF IL 251 (Lat: 42.165564,  Lng: -89.099358),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 5.68m (18.64ft),  Average Daily Traffic: 525 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 750 (year 2040),  Design Load: HS 20,  Features Intersected: KILBUCK CR,  Facility Carried by Structure: SOUTH BEND RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.681,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.1m (46.3ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 1013084,  Location: 0.2 MI. E. OF IL 2 (Lat: 42.335958,  Lng: -89.074661),  Route carried "on" structure: Other road ,  Year Built: 1989,  Status: Open,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 4,600 (year 2012),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,800 (year 2040),  Design Load: HS 20,  Features Intersected: ICE LINE RAILROAD,  Facility Carried by Structure: FRANK BAUER PARKWA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.7m (48.2ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013088,  Location: 0.65MI W IL 251 (Lat: 42.338194,  Lng: -89.066933),  Route carried "on" structure: Other road ,  Year Built: 1993,  Status: Open,  Structure Length: 30.24m (99.21ft),  Average Daily Traffic: 4,900 (year 2012),  Average Future Daily Traffic: 6,000 (year 2040),  Design Load: HS 20,  Features Intersected: ROCK RIVER,  Facility Carried by Structure: HARLEM RD - CH 25
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.094,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 1 degrees,  Navigation Control: Yes ( Vertical Clearance: 5.5m (18.0ft), Horizontal Clearance: 47.2m (154.9ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 50.0m (164.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2020,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013093,  Location: 1/4 MI S CUNNINGHAM (Lat: 42.258708,  Lng: -89.142314),  Route carried "on" structure: Other road ,  Year Built: 2002,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 7,800 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 22,300 (year 2040),  Design Load: HS 20,  Features Intersected: CN RR,  Facility Carried by Structure: SPRINGFIELD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.615,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Other
Find on map >>   Show street view

Structure Number: 1013095,  Location: 5 MI SE OF WINNEBAGO (Lat: 42.208433,  Lng: -89.157531),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 150 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 370 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: TIPPLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.287,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.4m (50.5ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013096,  Location: 0.1 M S SPRING CR RD (Lat: 42.292528,  Lng: -89.038411),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 1.54m (5.05ft),  Average Daily Traffic: 650 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: BROOKVIEW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.113,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10131,  Location: 1.5 MI SW BELT LINE (Lat: 42.185133,  Lng: -89.130564),  Route carried "on" structure: Other road ,  Year Built: 2011,  Status: Open,  Structure Length: 14.04m (46.06ft),  Average Daily Traffic: 5,100 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 6,300 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: KISHWAUKEE RIVER,  Facility Carried by Structure: KISHWAUKEE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.557,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 53.0m (173.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 78.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013101,  Location: 0.25 MI E PIERPONT (Lat: 42.265461,  Lng: -89.130219),  Route carried "on" structure: Other road ,  Year Built: 2011,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 2,150 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 2,200 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: SO BR KENT CREEK,  Facility Carried by Structure: CUNNINGHAM ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.851,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.2m (69.6ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1013104,  Location: .1 MI E MERIDIAN RD (Lat: 42.261200,  Lng: -89.168286),  Route carried "on" structure: Other road ,  Year Built: 2016,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 1,100 (year 2017),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,260 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: S BR KENT CREEK,  Facility Carried by Structure: CUNNINGHAM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.888,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1015003,  Location: 0.3 MI N STATE ST (Lat: 42.284347,  Lng: -89.173497),  Route carried "on" structure: Other road ,  Year Built: 1968,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 5,600 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,500 (year 2040),  Design Load: HS 20,  Features Intersected: UNNAMED CREEK,  Facility Carried by Structure: MERIDIAN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.327,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.6m (8.5ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 88.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 69.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1015004,  Location: 1.2 MI S OF 20 BR (Lat: 42.264183,  Lng: -89.173592),  Route carried "on" structure: Other road ,  Year Built: 1964,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 5,400 (year 2017),  Average Future Daily Traffic: 5,600 (year 2040),  Design Load: HS 20,  Features Intersected: S. BR. KENT CREEK,  Facility Carried by Structure: MERIDIAN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.580,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 88.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 88.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1015006,  Location: AT 20TH STREET (Lat: 42.237900,  Lng: -89.057628),  Route carried "on" structure: Other road ,  Year Built: 1956,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 12,800 (year 2012),  Truck Traffic: 8%,  Average Future Daily Traffic: 16,100 (year 2040),  Design Load: H 20,  Features Intersected: S.E. DRAINAGE WAY,  Facility Carried by Structure: HARRISON AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.128,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.6m (21.7ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1015023,  Location: BY KILBUCK CREEK (Lat: 42.164922,  Lng: -89.099903),  Route carried "on" structure: County highway ,  Year Built: 1926,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 525 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 900 (year 2040),  Design Load: H 15,  Features Intersected: BR KILBUCK CR,  Facility Carried by Structure: KILBUCK BLUFF FP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.600,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.6m (15.1ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 24.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 14.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1015024,  Location: AT FISH HATCHERY RD (Lat: 42.348672,  Lng: -89.223769),  Route carried "on" structure: County highway ,  Year Built: 1936,  Year Reconstructed: 1966,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 150 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 100 (year 2040),  Design Load: H 15,  Features Intersected: BR PECATONICA RIVER,  Facility Carried by Structure: EDDIE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.616,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1015037,  Location: 0.2 MI E PRAIRIE RD (Lat: 42.223203,  Lng: -89.122378),  Route carried "on" structure: Other road ,  Year Built: 1959,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 950 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 1,500 (year 2040),  Design Load: HS 20,  Features Intersected: FULLERS CR,  Facility Carried by Structure: SIMPSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Poor,  Culverts: Poor,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 1015038,  Location: AT RT 20 BYPASS (Lat: 42.225647,  Lng: -89.124856),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 1,300 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,400 (year 2040),  Design Load: HS 20,  Features Intersected: FULLERS CR,  Facility Carried by Structure: PRAIRIE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 1015043,  Location: .01 N OF SPRINGBROOK (Lat: 42.304122,  Lng: -88.999622),  Route carried "on" structure: Other road ,  Year Built: 1964,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 19,900 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 32,300 (year 2040),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: MULFORD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.235,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 1015046,  Location: 0.5 MI N GUILFORD RD (Lat: 42.290689,  Lng: -88.999611),  Route carried "on" structure: Other road ,  Year Built: 1961,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 11,800 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 31,400 (year 2040),  Design Load: H 20,  Features Intersected: KEITH CREEK,  Facility Carried by Structure: MULFORD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.764,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1015054,  Location: 0.5 MI W HARRISON RD (Lat: 42.377219,  Lng: -89.203028),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Posted for load,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 75 (year 2017),  Average Future Daily Traffic: 75 (year 2040),  Design Load: HS 15,  Features Intersected: TUNNISON CREEK,  Facility Carried by Structure: TR-83 (KNAPP ROAD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.1m (13.5ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 20.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 12.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1015055,  Location: 0.7 N AUBURN ST (Lat: 42.301339,  Lng: -89.184442),  Route carried "on" structure: City street ,  Year Built: 1957,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 100 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 15,  Features Intersected: KENT CREEK,  Facility Carried by Structure: HARRISON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Rockford, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.