No violation noted during this evaluation. | 07/28/2014 | Routine |
- Plumbing system / repair (Critical) (corrected)
Plumbing system(s) not maintained in good repair.
Correction: Plumbing system(s) shall be repaired and maintained.
Comments: PROVIDE FLOOR DRAIN COVERS FOR ALL FLOOR DRAINS UNDER FRONT COUNTER.
- Unapproved non-food contact (corrected)
Unapproved material(s) used in non-food contact surface(s).
Correction: Surfaces of equipment that are exposed to splash, spillage, or other food soiling conditions shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Comments: REPLACE ALL PAINTED WOOD SHELVING ALONG WALL, ON METAL SHELVING RACKS,AND ON THE HOT WATER DISPENSER WITH AND APPROVED MATERIAL THAT IS NON POUROUS, SMOOTH AND EASILY CLEANABLE, SUCH AS STAINLESS STEEL.
- Hood system design and/or installation
Heating air conditioning and/or ventilating systems improperly designed or installed.
Correction: Heating, ventilating, and air conditioning systems shall be properly designed and installed.
Comments: HOOD SYSTEM IS NOT PROPERLY INSTALLED. THE VENT ON THE BACK WALL IS CLOSED OFF AND NO MAKE UP AIR GETS INTO THE FACILITY CAUSING NEGATIVE PRESSURE IN TURN CAUSES THE PILOT LIGHTS IN THE WATER HEATER TO BLOW OUT. REPAIR TO WORKING ORDER.
- Physical facility repair (corrected)
Physical facility not maintained in good repair.
Correction: The physical facility shall be maintained in good repair.
Comments: REMOVE ALL PEELING PAINT THROUGHOUT THE STAND ON WALLS, CEILINGS, AND LIGHT FIXTURES.REPAIR /REPLACE THE DAMAGED ROOF AREAS TO ELMINATE THE ENTRY OF RAIN/SNOW/VERMIN. ROOF LEAKS ALONG THE BACK WALL OF STAND 14ELMINATE THE EXCESSIVE EXTENTION CORDS. PROVIDE ADDITIONAL OUTLETS TO SUPPORT THE POWER NEEDS. MAY NEED TO INSTALL ADDITIONAL ELECTRICAL BREAKERS.THE SERVICE WINDOWS ARE DAMAGED AND ARE ALLOWING OUTSIDE ELEMENTS SUCH AS RAIN, SNOW AND VERMIN TO ENTER THE ESTABLISHMENT. REPLACE THE WINDOWS TO PROPERLY SEAL.CAP OFF THE RAISED PVC/COPPER PIPING COMING THRU THE FLOOR WHERE THE OLD SODA LINES USED TO GO INTO TO ELMINATE THE ACCUMULATION OF DEBRIS.CAP OFF THE PVC PIPING WHERE THE OLD SODA WASTE WATER LINES WENT TO ELMINATE THE OPEN DRAIN LINE.CEILING IN FRONT OF THE HOOD IN STAND 14 IS CRACKED, REPAIR.CEILING AND WALL DAMAGE THROUGHOUT STAND 14, BACK WALL IS BOWING. REPAIR.
|
04/08/2014 | Pre-Licensing Recheck |
- Plumbing system / repair (Critical)
Plumbing system(s) not maintained in good repair.
Correction: Plumbing system(s) shall be repaired and maintained.
Comments: PROVIDE FLOOR DRAIN COVERS FOR ALL FLOOR DRAINS UNDER FRONT COUNTER.
- Unapproved non-food contact
Unapproved material(s) used in non-food contact surface(s).
Correction: Surfaces of equipment that are exposed to splash, spillage, or other food soiling conditions shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Comments: REPLACE ALL PAINTED WOOD SHELVING ALONG WALL, ON METAL SHELVING RACKS,AND ON THE HOT WATER DISPENSER WITH AND APPROVED MATERIAL THAT IS NON POUROUS, SMOOTH AND EASILY CLEANABLE, SUCH AS STAINLESS STEEL.
- Hood system design and/or installation
Heating air conditioning and/or ventilating systems improperly designed or installed.
Correction: Heating, ventilating, and air conditioning systems shall be properly designed and installed.
Comments: HOOD SYSTEM IS NOT PROPERLY INSTALLED. THE VENT ON THE BACK WALL IS CLOSED OFF AND NO MAKE UP AIR GETS INTO THE FACILITY CAUSING NEGATIVE PRESSURE IN TURN CAUSES THE PILOT LIGHTS IN THE WATER HEATER TO BLOW OUT. REPAIR TO WORKING ORDER.
- Physical facility repair
Physical facility not maintained in good repair.
Correction: The physical facility shall be maintained in good repair.
Comments: REMOVE ALL PEELING PAINT THROUGHOUT THE STAND ON WALLS, CEILINGS, AND LIGHT FIXTURES.REPAIR /REPLACE THE DAMAGED ROOF AREAS TO ELMINATE THE ENTRY OF RAIN/SNOW/VERMIN. ROOF LEAKS ALONG THE BACK WALL OF STAND 14ELMINATE THE EXCESSIVE EXTENTION CORDS. PROVIDE ADDITIONAL OUTLETS TO SUPPORT THE POWER NEEDS. MAY NEED TO INSTALL ADDITIONAL ELECTRICAL BREAKERS.THE SERVICE WINDOWS ARE DAMAGED AND ARE ALLOWING OUTSIDE ELEMENTS SUCH AS RAIN, SNOW AND VERMIN TO ENTER THE ESTABLISHMENT. REPLACE THE WINDOWS TO PROPERLY SEAL.CAP OFF THE RAISED PVC/COPPER PIPING COMING THRU THE FLOOR WHERE THE OLD SODA LINES USED TO GO INTO TO ELMINATE THE ACCUMULATION OF DEBRIS.CAP OFF THE PVC PIPING WHERE THE OLD SODA WASTE WATER LINES WENT TO ELMINATE THE OPEN DRAIN LINE.CEILING IN FRONT OF THE HOOD IN STAND 14 IS CRACKED, REPAIR.CEILING AND WALL DAMAGE THROUGHOUT STAND 14, BACK WALL IS BOWING. REPAIR.
|
01/23/2014 | Pre-Licensing |
Restaurant representatives - add corrected or new information about IMS - STAND 13 & 14, 4790 W 16TH ST, Speedway, IN »