  • National Bridge Inventory (NBI) Statistics
  • 322Number of bridges
  • 3,845ft / 1,172mTotal length
  • $10,930,000Total costs
  • 4,776,082Total average daily traffic
  • 338,656Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lansing
  • No street view available for this location

New bridges in Lansing, MI - historical statistics
  • New bridges - historical statistics
  • 121920-1929
  • 71930-1939
  • 31940-1949
  • 111950-1959
  • 1051960-1969
  • 821970-1979
  • 381980-1989
  • 191990-1999
  • 352000-2009
  • 82010-2019
  • 22020-2022
Reconstructed bridges in Lansing, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 11970-1979
  • 61980-1989
  • 121990-1999
  • 172000-2009
  • 32010-2019
Average Bridge Daily Traffic in Lansing, MI
Average Bridge Truck Traffic in Lansing, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.0%Excellent
  • 5.6%Very good
  • 26.4%Good
  • 47.2%Satisfactory
  • 14.7%Fair
  • 4.1%Poor
  • 1.0%Serious
  • 0.5%Critical
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.0%Excellent
  • 7.1%Very good
  • 15.7%Good
  • 38.1%Satisfactory
  • 31.0%Fair
  • 4.1%Poor
  • 2.5%Serious
  • 0.5%Critical
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.0%Excellent
  • 6.6%Very good
  • 25.9%Good
  • 47.2%Satisfactory
  • 14.7%Fair
  • 4.6%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 0.8%Excellent
  • 7.4%Very good
  • 31.4%Good
  • 46.3%Satisfactory
  • 11.6%Fair
  • 2.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 4.0%Excellent
  • 24.0%Very good
  • 32.0%Good
  • 20.0%Satisfactory
  • 12.0%Fair
  • 4.0%Poor
  • 4.0%Serious
Find on map >>   Show street view

Structure Number: 3936,  Location: IN THE CITY OF LANSING (Lat: 42.721892,  Lng: -84.548861),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Posted for load,  Structure Length: 3.92m (12.86ft),  Average Daily Traffic: 2,000 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,300 (year 2031),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: E ELM STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.541,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.6m (64.3ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Fair,  Superstructure: Serious,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 16.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 2.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3937,  Location: IN THE CITY OF LANSING (Lat: 42.729992,  Lng: -84.547139),  Route carried "on" structure: City street 2003,  Year Built: 1979,  Status: Open,  Structure Length: 12.74m (41.80ft),  Average Daily Traffic: 7,875 (year 2006),  Truck Traffic: 10%,  Average Future Daily Traffic: 14,223 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: KALAMAZOO STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.676,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 48.1m (157.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 21.4m (70.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 3939,  Location: IN THE CITY OF LANSING (Lat: 42.737286,  Lng: -84.548653),  Route carried "on" structure: City street 2003,  Year Built: 1996,  Status: Open,  Structure Length: 11.70m (38.39ft),  Average Daily Traffic: 5,675 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,249 (year 2030),  Design Load: HS 20,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: SHIAWASSEE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.973,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.0m (128.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 394,  Location: IN THE CITY OF LANSING (Lat: 42.747450,  Lng: -84.550314),  Route carried "on" structure: City street 2003,  Year Built: 1929,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 5,825 (year 2006),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,520 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: CESAR CHAVEZ AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.782,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 4.2m (13.8ft),  Right: 4.2m (13.8ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 25.3m (83.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3944,  Location: IN THE CITY OF LANSING (Lat: 42.756028,  Lng: -84.567564),  Route carried "on" structure: City street 2003,  Year Built: 1960,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 13.47m (44.19ft),  Average Daily Traffic: 9,625 (year 2006),  Truck Traffic: 15%,  Average Future Daily Traffic: 17,383 (year 2026),  Design Load: HS 20,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: N MARTINLUTHERKING
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.487,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 3),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.46m (44.16ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $2,728,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $2,749,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 3947,  Location: IN THE CITY OF LANSING (Lat: 42.749914,  Lng: -84.555275),  Route carried "on" structure: City street 2003,  Year Built: 1924,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 3,815 (year 2009),  Truck Traffic: 34%,  Average Future Daily Traffic: 4,578 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: N GRAND RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.751,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 60.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3948,  Location: IN THE CITY OF LANSING (Lat: 42.724664,  Lng: -84.552322),  Route carried "on" structure: City street 2003,  Year Built: 1987,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 9,050 (year 2011),  Average Future Daily Traffic: 9,997 (year 2021),  Design Load: HS 20+Mod,  Features Intersected: GRAND RIVER,  Facility Carried by Structure: S WASHINGTON AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.285,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.9m (150.6ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 23.6m (77.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3951,  Location: IN THE CITY OF LANSING (Lat: 42.703625,  Lng: -84.538150),  Route carried "on" structure: City street 2003,  Year Built: 2005,  Status: Open,  Structure Length: 6.50m (21.33ft),  Average Daily Traffic: 13,400 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,403 (year 2021),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: PENNSYLVANIA AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.743,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 7 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 64.0m (210.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3952,  Location: IN THE CITY OF LANSING (Lat: 42.718061,  Lng: -84.538108),  Route carried "on" structure: City street 2003,  Year Built: 1963,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 17,675 (year 2010),  Truck Traffic: 15%,  Average Future Daily Traffic: 31,923 (year 2030),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: PENNSYLVANIA AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.396,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 3955,  Location: IN THE CITY OF LANSING (Lat: 42.716633,  Lng: -84.522603),  Route carried "on" structure: City street 2003,  Year Built: 1972,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 9,450 (year 2010),  Average Future Daily Traffic: 10,543 (year 2021),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: AURELIUS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 27.894,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 4.2m (13.8ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3956,  Location: IN THE CITY OF LANSING (Lat: 42.719383,  Lng: -84.522272),  Route carried "on" structure: City street 2003,  Year Built: 2021,  Status: Open,  Structure Length: 3.19m (10.47ft),  Average Daily Traffic: 8,715 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,635 (year 2039),  Design Load: Greater than HL93,  Features Intersected: GRAND TRUNK RAILROAD,  Facility Carried by Structure: AURELIUS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 28.189,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.9m (101.4ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3958,  Location: IN THE CITY OF LANSING (Lat: 42.721267,  Lng: -84.544403),  Route carried "on" structure: City street ,  Year Built: 2007,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 1,580 (year 2001),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,870 (year 2027),  Design Load: HS 25 or greater,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: BEECH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.151,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4111,  Location: 2.8 MI N OF ARENAC COL (Lat: 44.201556,  Lng: -83.803294),  Route carried "on" structure: State highway 65,  Year Built: 1950,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 4,353 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,006 (year 2038),  Design Load: HS 20,  Features Intersected: JOHNSON CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.434,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 335,  Subroute: 38),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4115,  Location: 6.0 MI N OF M-55 (Lat: 44.360825,  Lng: -83.804381),  Route carried "on" structure: State highway 65,  Year Built: 1952,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 6,737 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,849 (year 2018),  Design Load: HS 20,  Features Intersected: BR HALE CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.132,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 335,  Subroute: 38),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4119,  Location: 0.8 MI E OF OGEMAW COL (Lat: 44.277036,  Lng: -83.866000),  Route carried "on" structure: State highway 55,  Year Built: 1929,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 2,529 (year 2007),  Truck Traffic: 15%,  Average Future Daily Traffic: 3,686 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: AU GRES RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.392,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 125,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6642,  Location: 4.9 MI S OF MANISTEE COL (Lat: 44.120481,  Lng: -86.279978),  Route carried "on" structure: US 31,  Year Built: 1959,  Status: Open,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 6,578 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 9,001 (year 2018),  Design Load: HS 20,  Features Intersected: BIG SABLE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.793,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 21,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6687,  Location: 4 MI W 4.5 M N SCOTTVILLE (Lat: 44.020225,  Lng: -86.360619),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 300 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 350 (year 2017),  Design Load: HS 20,  Features Intersected: N BR LINCOLN RIVER,  Facility Carried by Structure: VICTORY CORNER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.728,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6688,  Location: 2 MI W 4 MI N SCOTTVILLE (Lat: 44.015058,  Lng: -86.320017),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 120 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 150 (year 2017),  Design Load: HS 20+Mod,  Features Intersected: S BR LINCOLN RIVER,  Facility Carried by Structure: AMBER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.277,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 83.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 6742,  Location: 2 MI NW OF BIG RAPIDS (Lat: 43.742764,  Lng: -85.530500),  Route carried "on" structure: Business US 131,  Year Built: 1982,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 4,635 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 6,351 (year 2018),  Design Load: HS 20,  Features Intersected: US-131 NB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.588,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.6m (139.8ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 89.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6853,  Location: 1.5 MI. N OF HOULE (Lat: 45.724572,  Lng: -87.396931),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 20 (year 2005),  Average Future Daily Traffic: 25 (year 2019),  Design Load: HS 20+Mod,  Features Intersected: FORTY SEVEN MILE CREEK,  Facility Carried by Structure: D-3 ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.107,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 7187,  Location: 1.6 MI N OF STATE LINE (Lat: 41.768203,  Lng: -83.480697),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 1976,  Status: Open,  Structure Length: 12.68m (41.60ft),  Average Daily Traffic: 1,456 (year 2007),  Truck Traffic: 27%,  Average Future Daily Traffic: 6,240 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.608,  Lanes on structure: 1,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 46.3m (151.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 77.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 18 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7268,  Location: 4.25 MI N OF IDA WEST RD (Lat: 41.964611,  Lng: -83.546264),  Route carried "on" structure: County highway 5833,  Year Built: 1958,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 2,666 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 3,066 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: MILL RACE,  Facility Carried by Structure: IDA MAYBEE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.674,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.4m (27.6ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7269,  Location: .15 MI E OF IDA MAYBEE RD (Lat: 42.006597,  Lng: -83.531342),  Route carried "on" structure: County highway 5837,  Year Built: 1979,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 1,038 (year 2000),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,245 (year 2020),  Design Load: HS 20,  Features Intersected: SANDY CREEK,  Facility Carried by Structure: STONE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.702,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 68.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7558,  Location: 11.5 MI E OF US-31 (Lat: 43.235083,  Lng: -85.975625),  Route carried "on" structure: State highway 46,  Year Built: 1958,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 6,182 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 8,513 (year 2018),  Design Load: HS 20,  Features Intersected: BIG DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.171,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 85,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Other
Find on map >>   Show street view

Structure Number: 7781,  Location: 4.0 MI S OF FREMONT (Lat: 43.409275,  Lng: -85.938336),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 199 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 360 (year 2026),  Design Load: HS 20,  Features Intersected: BUTLER CREEK,  Facility Carried by Structure: 80 TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.182,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8017,  Location: 4.1 MI SE OF M-15 (Lat: 42.720778,  Lng: -83.349300),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 42,870 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 55,750 (year 2029),  Design Load: HS 20,  Features Intersected: CLINTONVILLE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 44.918,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.8m (58.4ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8036,  Location: 5.4 MI NW OF M-15 (Lat: 42.782150,  Lng: -83.534492),  Route carried "on" structure: County highway 6380,  Year Built: 1962,  Status: Open,  Structure Length: 10.39m (34.09ft),  Average Daily Traffic: 6,708 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,379 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: I-75,  Facility Carried by Structure: EAST HOLLY RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.743,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.6m (116.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 10.40m (34.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Bridge Improvement Cost: $247,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $149,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 8644,  Location: SECTION 6 T17N R7W (Lat: 43.900708,  Lng: -85.201475),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 62 (year 2016),  Truck Traffic: 13%,  Average Future Daily Traffic: 120 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: THORN CREEK,  Facility Carried by Structure: 6 MILE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.255,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 8714,  Location: 3.7 MI SW OF KENT CO LINE (Lat: 42.880606,  Lng: -85.843628),  Route carried "on" structure: State highway 121,  Year Built: 1972,  Status: Open,  Structure Length: 1.73m (5.68ft),  Average Daily Traffic: 7,552 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 9,582 (year 2018),  Design Load: HS 20,  Features Intersected: RUSH CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.655,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 370,  Subroute: 73),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.3m (56.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 88.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8857,  Location: SECTION 31 ALLENDALE TWP (Lat: 42.942789,  Lng: -86.004997),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 3,880 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,010 (year 2040),  Design Load: H 20,  Features Intersected: BASS CREEK,  Facility Carried by Structure: FILLMORE ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.931,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8859,  Location: SECTION 20 BLENDON TWP (Lat: 42.899833,  Lng: -85.990867),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 180 (year 2039),  Design Load: HS 20,  Features Intersected: BELT DRAIN,  Facility Carried by Structure: TYLER STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.511,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8861,  Location: SECTION 11 BLENDON TWP (Lat: 42.928742,  Lng: -85.936497),  Route carried "on" structure: County highway ,  Year Built: 2016,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 100 (year 2020),  Average Future Daily Traffic: 180 (year 2040),  Design Load: HL 93,  Features Intersected: BASS CREEK,  Facility Carried by Structure: TAYLOR STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.019,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 4 degrees,  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 5.1m (16.7ft),  Out-to-Out Width: 6.6m (21.7ft)

Condition: Channel: Very good,  Culverts: Excellent,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 8976,  Location: 5.5 MI N OF ONAWAY (Lat: 45.446236,  Lng: -84.216533),  Route carried "on" structure: County highway 7107,  Year Built: 2015,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 1,375 (year 2014),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,483 (year 2034),  Design Load: Greater than HL93,  Features Intersected: RAINY RIVER,  Facility Carried by Structure: HWY 489
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.754,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.7m (64.6ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 64.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9148,  Location: N JCT I-75 (Lat: 43.498453,  Lng: -83.929783),  Route carried "on" structure: Interstate 675,  Year Built: 1971,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 10.72m (35.17ft),  Average Daily Traffic: 3,061 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,250 (year 2037),  Design Load: HS 20,  Features Intersected: I-75
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.405,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.5m (129.6ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 99.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $213,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 915,  Location: 0.5 MI S OF I-75 (Lat: 43.494025,  Lng: -83.936669),  Route carried "on" structure: Interstate 675,  Year Built: 1971,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 9.33m (30.61ft),  Average Daily Traffic: 3,061 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,250 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: KOCHVILLE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.691,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 46,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 41.6m (136.5ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 2 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9158,  Location: 3.6 MI SE OF M-46 (Lat: 43.365203,  Lng: -83.867514),  Route carried "on" structure: County highway 2004,  Year Built: 2015,  Status: Open,  Structure Length: 6.04m (19.82ft),  Average Daily Traffic: 1,530 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,800 (year 2035),  Design Load: Greater than HL93,  Features Intersected: I-75,  Facility Carried by Structure: BAKER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.414,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.7m (97.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 9394,  Location: 0.9 MI N OF DICE ROAD (Lat: 43.480897,  Lng: -84.220397),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1991,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 103 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 108 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: WEEKS DRAIN,  Facility Carried by Structure: FEHN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.306,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Gravel,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 9395,  Location: 0.2 MI N OF DICE ROAD (Lat: 43.467925,  Lng: -84.210522),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 118 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 124 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: WHITMORE DRAIN,  Facility Carried by Structure: RAUCHOLZ ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.242,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing