Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Wichita, Kansas (KS)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 786Number of bridges
  • 16,591ft / 5,057mTotal length
  • $13,844,000Total costs
  • 9,470,559Total average daily traffic
  • 625,083Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wichita
  • No street view available for this location

New bridges in Wichita, KS - historical statistics
  • New bridges - historical statistics
  • 41900-1909
  • 41910-1919
  • 71920-1929
  • 81930-1939
  • 151940-1949
  • 811950-1959
  • 1311960-1969
  • 1341970-1979
  • 931980-1989
  • 1521990-1999
  • 742000-2009
  • 742010-2019
  • 92020-2022
Reconstructed bridges in Wichita, KS - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 61960-1969
  • 241970-1979
  • 331980-1989
  • 281990-1999
  • 182000-2009
  • 142010-2019
  • 182020-2022
Average Bridge Daily Traffic in Wichita, KS
Average Bridge Truck Traffic in Wichita, KS
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 17.6%Very good
  • 62.2%Good
  • 14.9%Satisfactory
  • 4.8%Fair
  • 0.5%Poor
  • 0.2%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.8%Very good
  • 54.3%Good
  • 16.1%Satisfactory
  • 5.7%Fair
  • 0.2%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Very good
  • 55.0%Good
  • 9.3%Satisfactory
  • 2.3%Fair
  • 0.2%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 24.6%Very good
  • 56.9%Good
  • 15.6%Satisfactory
  • 1.9%Fair
  • 1.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 0.4%Excellent
  • 13.2%Very good
  • 65.4%Good
  • 16.0%Satisfactory
  • 3.5%Fair
  • 1.6%Poor
Find on map >>   Show street view

Structure Number: 5304008700LAR6,  Location: BITTING AT TWELFTH ST N (Lat: 37.706233,  Lng: -97.348408),  Route carried "on" structure: City street ,  Year Built: 1935,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 4,700 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,000 (year 2039),  Design Load: HS 20,  Features Intersected: LITTLE ARKANSAS RIVER,  Facility Carried by Structure: BITTING
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5304008700LAR7,  Location: 13TH ST N AT LEWELLEN (Lat: 37.707933,  Lng: -97.346119),  Route carried "on" structure: City street ,  Year Built: 1932,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 17,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 21,000 (year 2039),  Design Load: HS 20,  Features Intersected: LITTLE ARKANSAS RIVER,  Facility Carried by Structure: 13TH STREET NORTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.5m (47.6ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5304008700LAR8,  Location: 18TH ST. N@ ARKANSAS AVE. (Lat: 37.717058,  Lng: -97.345681),  Route carried "on" structure: City street ,  Year Built: 1914,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 5,600 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,400 (year 2039),  Design Load: HS 20,  Features Intersected: LITTLE ARKANSAS RIVER,  Facility Carried by Structure: 18TH STREET NORTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5304008700LBS05,  Location: HYDRAULIC AT 57TH SOUTH (Lat: 37.589033,  Lng: -97.315556),  Route carried "on" structure: City street ,  Year Built: 1962,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 3,800 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,000 (year 2039),  Design Load: HS 20,  Features Intersected: BIG SLOUGH SOUTH,  Facility Carried by Structure: HYDRAULIC AVENUE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5304008700LBS1,  Location: 55TH ST S AT MEAD (Lat: 37.593578,  Lng: -97.326722),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 3,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,000 (year 2039),  Design Load: HS 20,  Features Intersected: BIG SLOUGH SOUTH,  Facility Carried by Structure: 55TH STREET SOUTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700LBS25,  Location: BROADWAY AT 44 TH ST. S (Lat: 37.613664,  Lng: -97.334061),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 14,000 (year 2006),  Truck Traffic: 10%,  Average Future Daily Traffic: 20,000 (year 2039),  Design Load: HS 15,  Features Intersected: BIG SLOUGH CREEK,  Facility Carried by Structure: BROADWAY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.0m (52.5ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700LBS3,  Location: 31ST ST S AT GLENN (Lat: 37.636928,  Lng: -97.361750),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 9,800 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 11,500 (year 2039),  Design Load: HS 20,  Features Intersected: BIG SLOUGH SOUTH TRIB.,  Facility Carried by Structure: 31ST STREET SOUTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.2m (43.3ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 5304008700MCR1,  Location: MID. CONT. RD.@ Trail (Lat: 37.669519,  Lng: -97.427778),  Route carried "on" structure: City street 6007,  Year Built: 1981,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 8,250 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,250 (year 2039),  Design Load: HS 20,  Features Intersected: Walking Trail,  Facility Carried by Structure: MID. CON. DR. (SB)
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700MCR2,  Location: MID. CONT. RD.@ Trail (Lat: 37.669600,  Lng: -97.427778),  Route carried "on" structure: City street 6007,  Year Built: 1981,  Status: Open,  Structure Length: 9.21m (30.22ft),  Average Daily Traffic: 8,250 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,250 (year 2039),  Design Load: HS 20,  Features Intersected: Walking Trail,  Facility Carried by Structure: MID. CON. DR. (NB)
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 5304008700MCR3,  Location: EISENHWR AP PKWY @ HARRY (Lat: 37.665306,  Lng: -97.427894),  Route carried "on" structure: City street 6007,  Year Built: 1980,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 6.07m (19.91ft),  Average Daily Traffic: 8,810 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,092 (year 2043),  Design Load: HS 20,  Features Intersected: HARRY STREET,  Facility Carried by Structure: EISENHOWER AP PKWY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: Local Agency,  Approaching Roadway Width: 20.0m (65.6ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.0m (82.0ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.22m (20.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Other Special Inspection Date: April 2017,  Bridge Improvement Cost: $250,000,  Roadway Improvement Cost: $150,000,  Total Project Cost: $400,000 ( Estimate for 2016),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 5304008700MCR4,  Location: EISNHWR AP PKWY@CROSSFLD (Lat: 37.660003,  Lng: -97.428908),  Route carried "on" structure: City street 6007,  Year Built: 1980,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 8,810 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,091 (year 2043),  Design Load: HS 20,  Features Intersected: CROSSFIELD ROAD,  Facility Carried by Structure: EISENHOWER AP PKWY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: Local Agency,  Approaching Roadway Width: 20.0m (65.6ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 80.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.88m (16.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Other Special Inspection Date: April 2017,  Bridge Improvement Cost: $250,000,  Roadway Improvement Cost: $150,000,  Total Project Cost: $400,000 ( Estimate for 2016),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 5304008700SBT01,  Location: 127TH ST E .6 M S DOUGLAS (Lat: 37.685039,  Lng: -97.189583),  Route carried "on" structure: City street ,  Year Built: 1900,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 1,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,500 (year 2039),  Design Load: H 20,  Features Intersected: SPRING BRANCH TRIB. NO.,  Facility Carried by Structure: 127TH STREET EAST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.1m (26.6ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT02,  Location: 143RD ST. AT TIMBER LAKE (Lat: 37.668333,  Lng: -97.171297),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 4,200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,000 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BR. FOURMILE CR,  Facility Carried by Structure: 143RD ST. E
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700SBT03,  Location: 143RD ST. S OF KELLOGG (Lat: 37.677814,  Lng: -97.171267),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 4,200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,000 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BR. TRIB,  Facility Carried by Structure: 143RD ST. E
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT04,  Location: HARRY E OF TAMARISK (Lat: 37.665000,  Lng: -97.159167),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 4,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,500 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BR FOUR MILE CR,  Facility Carried by Structure: HARRY ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700SBT05,  Location: 127TH ST N OF HARRY (Lat: 37.665000,  Lng: -97.189444),  Route carried "on" structure: City street ,  Year Built: 1992,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 1.93m (6.33ft),  Average Daily Traffic: 2,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,000 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING CREEK,  Facility Carried by Structure: 127TH ST. E
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 3.6m (11.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 23.9m (78.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700SBT06,  Location: FAWN GROVE W OF GREENWICH (Lat: 37.674375,  Lng: -97.208917),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 1.17m (3.84ft),  Average Daily Traffic: 200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 350 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BRANCH,  Facility Carried by Structure: FAWN GROVE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT07,  Location: SHILOH N OF HARRY (Lat: 37.665833,  Lng: -97.214561),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 350 (year 2039),  Design Load: HS 20,  Features Intersected: ROCK ROAD S. TRIB GYPSUM,  Facility Carried by Structure: SHILOH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT1,  Location: DOUGLAS E. OF GARNETT (Lat: 37.686622,  Lng: -97.190839),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 100 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 150 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BRANCH TRIB. NO.,  Facility Carried by Structure: DOUGLAS AVENUE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT2,  Location: GARNETT N. OF DOUGLAS (Lat: 37.688075,  Lng: -97.191878),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 1.47m (4.82ft),  Average Daily Traffic: 150 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 250 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BRANCH TRIB. NO.,  Facility Carried by Structure: GARNETT
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT3,  Location: TIPPERARY & BRISTOL (Lat: 37.697811,  Lng: -97.202442),  Route carried "on" structure: City street ,  Year Built: 1996,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 250 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BRANCH TRIB. NO.,  Facility Carried by Structure: TIPPERARY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SBT4,  Location: HARRY .3 M W GREENWICH (Lat: 37.664689,  Lng: -97.214167),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 6,000 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 8,000 (year 2039),  Design Load: HS 20,  Features Intersected: SPRING BRANCH,  Facility Carried by Structure: HARRY STREET
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 1.8m (5.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 11.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SSD2,  Location: SENECA 500' S OF 55TH (Lat: 37.591111,  Lng: -97.352239),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 7,200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,000 (year 2039),  Design Load: HS 20,  Features Intersected: TRIB TO WVCFLOODWAY,  Facility Carried by Structure: SENECA
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700SSD5,  Location: SENECA AND 61ST ST (Lat: 37.581044,  Lng: -97.352269),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 0.62m (2.03ft),  Average Daily Traffic: 7,200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,000 (year 2039),  Design Load: HS 20,  Features Intersected: TRIB TO WVCFLOODWAY,  Facility Carried by Structure: SENECA
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700TRR1,  Location: THORN AND ROCK RD (Lat: 37.754167,  Lng: -97.242778),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 100 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 100 (year 2039),  Design Load: HS 20,  Features Intersected: TRIB TO E FK CHISOLM CR,  Facility Carried by Structure: THORN ROAD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5304008700UBS1,  Location: 29TH AND RIDGE ROAD (Lat: 37.737736,  Lng: -97.420164),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 1,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,500 (year 2039),  Design Load: HS 20,  Features Intersected: BIG SLOUGH CREEK,  Facility Carried by Structure: 29TH ST. NORTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 63.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700UBS3,  Location: 37TH N WEST OF RIDGE ROAD (Lat: 37.752111,  Lng: -97.431436),  Route carried "on" structure: City street ,  Year Built: 1971,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 2,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,000 (year 2039),  Design Load: HS 20,  Features Intersected: BIG SLOUGH CREEK,  Facility Carried by Structure: 37TH STREET NORTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5304008700WDC7,  Location: DOUGLAS AT I -135 (Lat: 37.686183,  Lng: -97.313142),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 13,500 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,000 (year 2039),  Design Load: HS 20,  Features Intersected: WICHITA DRAINAGE CANAL,  Facility Carried by Structure: DOUGLAS AVENUE
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 77.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5304008700WDC8,  Location: 1ST ST AT I-135 (Lat: 37.688139,  Lng: -97.313767),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 8,000 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,500 (year 2039),  Design Load: HS 20,  Features Intersected: WICHITA DRAINAGE CANAL,  Facility Carried by Structure: FIRST STREET NORTH
Minimum Vertical Clearance: 4.64m (15.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5304008700WDC9,  Location: 2ND ST AT I-135 (Lat: 37.689942,  Lng: -97.314389),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 11,000 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 12,500 (year 2039),  Design Load: HS 20,  Features Intersected: WICHITA DRAINAGE CANAL,  Facility Carried by Structure: SECOND STREET
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 88.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 5304008700WEP1,  Location: WILSON ESTATES & REDBRUSH (Lat: 37.719294,  Lng: -97.236911),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 350 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 500 (year 2039),  Design Load: HS 20,  Features Intersected: TRIB TO GYPSUM CR,  Facility Carried by Structure: WILSON ESTATES
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 0.0m

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53040087037RR1,  Location: 37TH ST N .2 M E ROCK RD (Lat: 37.752269,  Lng: -97.241381),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 5,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,000 (year 2039),  Design Load: H 20,  Features Intersected: EAST FORK CHISHOLM CR TR,  Facility Carried by Structure: 37TH STREET NORTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.5m (47.6ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $15,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $25,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53040087060701,  Location: HARRY AT FABRIQUE (Lat: 37.664656,  Lng: -97.265608),  Route carried "on" structure: City street ,  Year Built: 1957,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 18,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 22,000 (year 2039),  Design Load: H 20,  Features Intersected: FABRIQUE BR. GYPSUM CK.,  Facility Carried by Structure: HARRY STREET
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53040087060702,  Location: LINCOLN AT FABRIQUE (Lat: 37.671933,  Lng: -97.264108),  Route carried "on" structure: City street ,  Year Built: 1952,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 11,500 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 14,000 (year 2039),  Design Load: H 20,  Features Intersected: FABRIQUE BR. GYPSUM CK.,  Facility Carried by Structure: LINCOLN STREET
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 530400870CCWR1,  Location: WESTFIELD AT ROLLING HILL (Lat: 37.686881,  Lng: -97.450544),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 400 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 450 (year 2039),  Design Load: H 20,  Features Intersected: WESTLINK TRIB COWSKIN CR,  Facility Carried by Structure: WESTFIELD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 530400870CCWR2,  Location: ROLLING HILLS AT WOOD LN (Lat: 37.687872,  Lng: -97.445258),  Route carried "on" structure: City street ,  Year Built: 1968,  Status: Posted for load,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 840 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 945 (year 2039),  Design Load: H 20,  Features Intersected: WESTLINK TRIB COWSKIN CR,  Facility Carried by Structure: ROLLING HILLS
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 20.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $350,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 530400870CCWR4,  Location: DELANO AT WESTLINK (Lat: 37.696350,  Lng: -97.451456),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 525 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 735 (year 2039),  Design Load: H 15,  Features Intersected: WESTLINK TRIB COWSKIN CR,  Facility Carried by Structure: DELANO
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 530400870CCWR45,  Location: MAPLE AT SEVILLE (Lat: 37.679408,  Lng: -97.456150),  Route carried "on" structure: City street ,  Year Built: 1948,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 13,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 18,200 (year 2039),  Design Load: HS 20,  Features Intersected: WESTLINK TRIB COWSKIN CR,  Facility Carried by Structure: MAPLE STREET
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.9m (52.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 79.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.10m (20.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $350,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 530400870CCWR5,  Location: 9th Street at Westlink (Lat: 37.700967,  Lng: -97.452639),  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 1.32m (4.33ft),  Average Daily Traffic: 575 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 785 (year 2039),  Design Load: HS 20,  Features Intersected: Westlink Tributary,  Facility Carried by Structure: 9th Street North
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 87.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 530400870CCWR6,  Location: HARVEST LN AT WESTLINK (Lat: 37.704433,  Lng: -97.454103),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Posted for load,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 755 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 850 (year 2039),  Design Load: H 20,  Features Intersected: WESTLINK TRIB COWSKIN CR,  Facility Carried by Structure: HARVEST LANE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $300,000,  Roadway Improvement Cost: $75,000,  Total Project Cost: $425,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 530400870CCWR7,  Location: 13TH ST AT WESTLINK (Lat: 37.708669,  Lng: -97.454050),  Route carried "on" structure: City street ,  Year Built: 1968,  Status: Posted for load,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 15,565 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 23,500 (year 2039),  Design Load: H 20,  Features Intersected: WESTLINK TRIB COWSKIN CR,  Facility Carried by Structure: 13TH STREET NORTH
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $200,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $300,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Wichita, Kansas (KS) on our hugely popular Kansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.