Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Denver, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 639Number of bridges
  • 25,479ft / 7,766mTotal length
  • $98,973,000Total costs
  • 26,880,358Total average daily traffic
  • 1,763,899Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Denver
  • No street view available for this location

New bridges in Denver, CO - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 41920-1929
  • 21930-1939
  • 31940-1949
  • 341950-1959
  • 551960-1969
  • 511970-1979
  • 811980-1989
  • 1701990-1999
  • 952000-2009
  • 1012010-2019
  • 412020-2022
Reconstructed bridges in Denver, CO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 41960-1969
  • 41970-1979
  • 81980-1989
  • 131990-1999
  • 72000-2009
  • 42010-2019
Average Bridge Truck Traffic in Denver, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 11.8%Very good
  • 41.7%Good
  • 38.9%Satisfactory
  • 6.5%Fair
  • 1.0%Poor
  • 0.3%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 16.8%Very good
  • 49.0%Good
  • 25.4%Satisfactory
  • 8.0%Fair
  • 0.8%Poor
  • 0.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 17.1%Very good
  • 51.5%Good
  • 26.1%Satisfactory
  • 4.8%Fair
  • 0.5%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 58.6%Very good
  • 30.3%Good
  • 9.4%Satisfactory
  • 1.6%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 2.2%Very good
  • 27.2%Good
  • 58.7%Satisfactory
  • 10.9%Fair
  • 1.1%Poor
Find on map >>   Show street view

Structure Number: F-16-IA,  Location: 3.4 MI S OF JCT SH 470 (Lat: 39.527528,  Lng: -105.094625),  Route carried "on" structure: State highway 121B,  Year Built: 1968,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 22,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 26,620 (year 2040),  Design Load: HS 20,  Features Intersected: BURNS DRAW,  Facility Carried by Structure: SH 121 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.048,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.9m (78.4ft),  Skew: 11 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Out-to-Out Width: 48.1m (157.8ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Inventory Rating: 62.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: F-16-IL,  Location: IN DENVER ON SO SANTA FE (Lat: 39.692500,  Lng: -104.994400),  Route carried "on" structure: US 85B,  Year Built: 1972,  Status: Open,  Structure Length: 6.54m (21.46ft),  Average Daily Traffic: 44,500 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,070 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: US 85 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.110,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.2m (105.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 30.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 6.65m (21.82ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $1,000,  Total Project Cost: $2,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F-16-IR,  Location: I25 & SPEER (Lat: 39.753600,  Lng: -105.015400),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 2010,  Status: Open,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 217,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 256,060 (year 2040),  Design Load: HL 93,  Features Intersected: SPEER ENTRANCE,  Facility Carried by Structure: I25 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.270,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 6 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 96.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 84.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-JB,  Location: IN DOUGLAS COUNTY (Lat: 39.509794,  Lng: -105.017394),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 6.54m (21.46ft),  Average Daily Traffic: 9,315 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 12,482 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SH 85 ML,  Facility Carried by Structure: TITAN PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.444,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-JK,  Location: IN DENVER (Lat: 39.701322,  Lng: -104.987058),  Route carried "on" structure: Interstate 25A,  Year Built: 2002,  Status: Open,  Structure Length: 49.90m (163.71ft),  Average Daily Traffic: 188,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 227,480 (year 2040),  Design Load: HL 93,  Features Intersected: BRDWY,BNSF,UPRR,RTD,LR,  Facility Carried by Structure: I25 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 332.811,  Lanes on structure: 10,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 52.7m (172.9ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 46.4m (152.2ft),  Curb-To-Curb Width: 51.2m (168.0ft),  Out-to-Out Width: 52.7m (172.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-JX,  Location: COLFAX AVE AT I25 (Lat: 39.740289,  Lng: -105.015931),  Route carried "on" structure: US 40C,  Year Built: 1984,  Status: Open,  Structure Length: 133.59m (438.29ft),  Average Daily Traffic: 49,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 54,390 (year 2040),  Design Load: HS 20,  Features Intersected: I25,RDWY,RR,S PLATTE RVR,  Facility Carried by Structure: US 40 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 27.985,  Lanes on structure: 6,  Lanes under structure: 15,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 37,  Length of Maximum Span: 46.0m (150.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 28.7m (94.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 50.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-KT,  Location: IN DENVER (Lat: 39.745681,  Lng: -105.053222),  Route carried "on" structure: State highway 95A,  Year Built: 1982,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,170 (year 2040),  Design Load: HS 20,  Features Intersected: SLOAN LAKE DRAINAGE,  Facility Carried by Structure: SH 95 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.429,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.1m (6.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 5.6m (18.4ft),  Curb-To-Curb Width: 23.5m (77.1ft),  Out-to-Out Width: 31.7m (104.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: F-16-MX,  Location: I25, US40, SH33, INTCHNG (Lat: 39.741028,  Lng: -105.013072),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1988,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 117,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 138,650 (year 2040),  Design Load: HS 20,  Features Intersected: RAMP TO I 25 NBND R,  Facility Carried by Structure: RAMP TO I 25 SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 40.0m (131.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NE,  Location: 0.5 MI SE OF SH470+US285 (Lat: 39.631825,  Lng: -105.160664),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 8.98m (29.46ft),  Average Daily Traffic: 10,599 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 12,189 (year 2041),  Design Load: HS 20,  Features Intersected: SH 470 ML,  Facility Carried by Structure: QUINCY AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.071,  Lanes on structure: 4,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 46.0m (150.9ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 27.2m (89.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NK,  Location: IN DENVER (Lat: 39.724897,  Lng: -105.016069),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1987,  Status: Open,  Structure Length: 11.03m (36.19ft),  Average Daily Traffic: 215,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 247,250 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SOUTH PLATTE RIVER R,  Facility Carried by Structure: RAMP TO I 25 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.159,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.3m (128.9ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 67.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NO,  Location: JCT I-25 AT 6TH AVE IN DE (Lat: 39.726422,  Lng: -105.011286),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1989,  Status: Open,  Structure Length: 20.24m (66.40ft),  Average Daily Traffic: 107,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 123,625 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: INTERCHANGE ROW R,  Facility Carried by Structure: RAMP TO I 25 NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.159,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 45.5m (149.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Inventory Rating: 79.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NW,  Location: RAMP OVER I25 TO WB COLFA (Lat: 39.740656,  Lng: -105.016892),  Route carried "on" structure: Ramp State highway 40C,  Year Built: 1987,  Status: Open,  Structure Length: 46.48m (152.49ft),  Average Daily Traffic: 49,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 54,390 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I25 ML,US40 ML,PLTE RVR,  Facility Carried by Structure: US 40 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.510,  Lanes on structure: 1,  Lanes under structure: 18,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 52.1m (170.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 27.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 12.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NX,  Location: RAMP OVER I25 TO SB I25 (Lat: 39.741003,  Lng: -105.014767),  Route carried "on" structure: Ramp City street ,  Year Built: 1987,  Status: Open,  Structure Length: 17.89m (58.69ft),  Average Daily Traffic: 10,126 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 11,240 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: I25,RAMPS AND WALNUT,  Facility Carried by Structure: AURARIA PKWY RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.258,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 62.5m (205.1ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NY,  Location: EB AURARIA PKWY (Lat: 39.741428,  Lng: -105.013833),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1988,  Status: Open,  Structure Length: 38.17m (125.23ft),  Average Daily Traffic: 106,000 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 124,020 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STEETS, RAMPS, RTD &,  Facility Carried by Structure: I25_EB AUR. PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 37.6m (123.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 38.17m (125.23ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $5,165,000,  Roadway Improvement Cost: $516,000,  Total Project Cost: $7,747,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-NZ,  Location: N.W. CORNER OF I25/SH40 (Lat: 39.741536,  Lng: -105.015472),  Route carried "on" structure: Ramp US 40C,  Year Built: 1988,  Status: Open,  Structure Length: 11.16m (36.61ft),  Average Daily Traffic: 49,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 54,390 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: RAMP TO US 40 ML R,  Facility Carried by Structure: RAMP TO US 40 ML
Minimum Vertical Clearance: 6.45m (21.16ft),  Kilometerpoint: 0.187,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-O,  Location: IN LAKEWOOD (Lat: 39.725400,  Lng: -105.081889),  Route carried "on" structure: US 6G,  Year Built: 1972,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 101,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 111,100 (year 2040),  Design Load: HS 20,  Features Intersected: SH 121 ML,  Facility Carried by Structure: US 6 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.206,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 34.1m (111.9ft)

Condition: Deck: Serious,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.73m (18.80ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $3,337,000,  Roadway Improvement Cost: $334,000,  Total Project Cost: $5,005,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F-16-OB,  Location: IN DENVER (Lat: 39.740094,  Lng: -105.013067),  Route carried "on" structure: Ramp US 40C,  Year Built: 1988,  Status: Open,  Structure Length: 10.97m (35.99ft),  Average Daily Traffic: 49,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 54,390 (year 2040),  Design Load: HS 20,  Features Intersected: RMP TO I25 NB,  Facility Carried by Structure: RMP TO I25/AUR.PKW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.082,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 1,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 53.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-OD,  Location: I25, US40, SH33 INTCHNG (Lat: 39.740636,  Lng: -105.012453),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1988,  Status: Open,  Structure Length: 11.06m (36.29ft),  Average Daily Traffic: 235,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 277,300 (year 2040),  Design Load: HS 20,  Features Intersected: BNSF RR R,  Facility Carried by Structure: WBCOLFAX RMP/I25ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.076,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-OE,  Location: I25/US6 INTCHNG IN DENVER (Lat: 39.724367,  Lng: -105.015078),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1987,  Status: Open,  Structure Length: 16.43m (53.90ft),  Average Daily Traffic: 107,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 123,625 (year 2040),  Design Load: HS 20,  Features Intersected: RAMP TO I 25 SBND R,  Facility Carried by Structure: EB6 RMP. TO I25 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.264,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-OG,  Location: JCT I25 + SH6 IN DENVER (Lat: 39.724492,  Lng: -105.014981),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1989,  Status: Open,  Structure Length: 42.01m (137.83ft),  Average Daily Traffic: 107,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 123,625 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US 6 ML,  Facility Carried by Structure: RAMP TO I 25 NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.232,  Lanes on structure: 2,  Lanes under structure: 16,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 46.0m (150.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 38.0m (124.7ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Serious,  Substructure: Good,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: F-16-OH,  Location: IN DENVER (Lat: 39.727386,  Lng: -105.013256),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1988,  Status: Open,  Structure Length: 19.14m (62.80ft),  Average Daily Traffic: 114,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 133,380 (year 2040),  Features Intersected: RAMP TO 8TH AVE R,  Facility Carried by Structure: 6THAVERMP TOI25 NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.362,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 46.1m (151.2ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 64.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-OK,  Location: I 25/US 6 INTCHNG IN DENV (Lat: 39.726022,  Lng: -105.010267),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1988,  Status: Open,  Structure Length: 9.46m (31.04ft),  Average Daily Traffic: 215,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 247,250 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BNSF RR R,  Facility Carried by Structure: RAMP TO I 25 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.061,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 46.6m (152.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-OL,  Location: JCT I25 + SH6 IN DENVER (Lat: 39.723739,  Lng: -105.012347),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 1989,  Status: Open,  Structure Length: 36.39m (119.39ft),  Average Daily Traffic: 107,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 123,625 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: RAMP TO I 25 SBND,  Facility Carried by Structure: 6TH AVE WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.425,  Lanes on structure: 1,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 52.6m (172.6ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Critical Feature Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: F-16-PH,  Location: .5 MI S. OF BOWLES (Lat: 39.602067,  Lng: -105.153472),  Route carried "on" structure: State highway 470A,  Year Built: 1988,  Status: Open,  Structure Length: 8.24m (27.03ft),  Average Daily Traffic: 29,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 39,150 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DUTCH CREEK,  Facility Carried by Structure: SH 470 ML WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.704,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.8m (133.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-PL,  Location: 2.06 MI N OF JCT US 285 (Lat: 39.678842,  Lng: -104.993608),  Route carried "on" structure: Ramp US 85B,  Year Built: 1986,  Status: Open,  Structure Length: 14.91m (48.92ft),  Average Daily Traffic: 76,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 91,960 (year 2040),  Design Load: HS 20,  Features Intersected: RAMP TO EVANS AVE[SE] R,  Facility Carried by Structure: RAMP/EVANS AVE SE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.354,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-PM,  Location: 2.09 MI N OF JCT US 285 (Lat: 39.678592,  Lng: -104.993081),  Route carried "on" structure: Ramp US 85B,  Year Built: 1986,  Status: Open,  Structure Length: 19.28m (63.25ft),  Average Daily Traffic: 38,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 45,980 (year 2040),  Design Load: HS 20,  Features Intersected: RAMP TO US 85 NBND[NE] R,  Facility Carried by Structure: RAMP TO US 85 NBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.014,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-PN,  Location: 2.10 MI N OF JCT US 285 (Lat: 39.676983,  Lng: -104.993453),  Route carried "on" structure: Ramp US 85B,  Year Built: 1986,  Status: Open,  Structure Length: 3.63m (11.91ft),  Average Daily Traffic: 76,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 91,960 (year 2040),  Design Load: HS 20,  Features Intersected: RAMP TO EVANS AVE[NW] R,  Facility Carried by Structure: RAMP/EVANS AVE NW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.310,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-PO,  Location: 2.07 MI N OF JCT US 285 (Lat: 39.677972,  Lng: -104.993903),  Route carried "on" structure: Ramp US 85B,  Year Built: 1986,  Status: Open,  Structure Length: 3.17m (10.40ft),  Average Daily Traffic: 38,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 45,980 (year 2040),  Features Intersected: RAMP TO US 85 SBND[SW] R,  Facility Carried by Structure: RAMP TO US 85 SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.060,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.0m (78.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-QJ,  Location: I25/US40 INTERCHANGE (Lat: 39.739811,  Lng: -105.015061),  Route carried "on" structure: Ramp Interstate 25A,  Year Built: 2003,  Status: Open,  Structure Length: 9.94m (32.61ft),  Average Daily Traffic: 117,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 138,650 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: WALNUT CONNECTOR R,  Facility Carried by Structure: SBND I25 RAMP H
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.192,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 40.1m (131.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-RT,  Location: HAMPDEN/SHERIDAN (Lat: 39.653428,  Lng: -105.052822),  Route carried "on" structure: US 285D,  Year Built: 1993,  Status: Open,  Structure Length: 5.87m (19.26ft),  Average Daily Traffic: 55,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 62,700 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SH 95 ML,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 152.170,  Lanes on structure: 5,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 34.1m (111.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.1m (95.5ft),  Curb-To-Curb Width: 36.9m (121.1ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-RU,  Location: .2 MI E OF SHERIDAN BLVD (Lat: 39.653528,  Lng: -105.048978),  Route carried "on" structure: US 285D,  Year Built: 1993,  Status: Open,  Structure Length: 7.63m (25.03ft),  Average Daily Traffic: 62,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 70,680 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 152.503,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 45.1m (148.0ft),  Skew: 6 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.9m (121.1ft),  Curb-To-Curb Width: 39.0m (128.0ft),  Out-to-Out Width: 40.9m (134.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-RY,  Location: 0.65 MI E OF SH 95 (Lat: 39.654375,  Lng: -105.041167),  Route carried "on" structure: US 285D,  Year Built: 1995,  Status: Open,  Structure Length: 2.94m (9.65ft),  Average Daily Traffic: 62,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 70,680 (year 2040),  Design Load: HS 20,  Features Intersected: RALEIGH STREET,  Facility Carried by Structure: US 285 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 153.182,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 35.7m (117.1ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 34.1m (111.9ft),  Out-to-Out Width: 36.0m (118.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 92.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-XA,  Location: IN DENVER ON SO SANTA FE (Lat: 39.702819,  Lng: -104.995533),  Route carried "on" structure: US 85B,  Year Built: 2015,  Status: Not yet open,  Structure Length: 26.37m (86.52ft),  Average Daily Traffic: 40,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 48,000 (year 2040),  Design Load: HL 93,  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: US 85 ML SBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 41.350,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 57.2m (187.7ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-XB,  Location: IN DENVER (Lat: 39.742914,  Lng: -105.015089),  Route carried "on" structure: Interstate 25A,  Year Built: 2011,  Status: Open,  Structure Length: 11.31m (37.11ft),  Average Daily Traffic: 212,000 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 248,040 (year 2040),  Features Intersected: RDWY,RR,SOUTH PLATTE RVR,  Facility Carried by Structure: I 25 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.591,  Lanes on structure: 10,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 58.5m (191.9ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 58.5m (191.9ft),  Out-to-Out Width: 60.0m (196.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-XJ,  Location: .3 MI S OF COLFAX (Lat: 39.734967,  Lng: -105.053228),  Route carried "on" structure: State highway 95A,  Year Built: 2010,  Status: Open,  Structure Length: 8.08m (26.51ft),  Average Daily Traffic: 30,000 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 31,200 (year 2038),  Design Load: HL 93,  Features Intersected: Light Rail & WtrDrai,  Facility Carried by Structure: SHERIDAN BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.199,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 41.1m (134.8ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-XK,  Location: JUST N OF HOLDEN (Lat: 39.736736,  Lng: -105.025050),  Route carried "on" structure: State highway 88A,  Year Built: 2011,  Status: Open,  Structure Length: 7.04m (23.10ft),  Average Daily Traffic: 39,000 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 38,080 (year 2031),  Design Load: HL 93,  Features Intersected: Light Rail,  Facility Carried by Structure: SH 88-FEDERAL BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.406,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.0m (75.5ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 29.0m (95.1ft),  Out-to-Out Width: 36.3m (119.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-XM,  Location: FEDERAL / 6 IN DENVER (Lat: 39.725278,  Lng: -105.024825),  Route carried "on" structure: State highway 88A,  Year Built: 2014,  Status: Open,  Structure Length: 1.96m (6.43ft),  Average Daily Traffic: 35,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 36,050 (year 2040),  Design Load: HL 93,  Features Intersected: WB C-D ROAD,  Facility Carried by Structure: SH 88-FEDERAL BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.682,  Lanes on structure: 9,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 39.7m (130.2ft),  Out-to-Out Width: 48.7m (159.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.49m (18.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F-16-XO,  Location: FEDERAL / 6 IN DENVER (Lat: 39.725664,  Lng: -105.025289),  Route carried "on" structure: State highway 88A,  Year Built: 2014,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 35,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 36,050 (year 2040),  Design Load: HL 93,  Features Intersected: US 6 ML,  Facility Carried by Structure: SH 88 ML FEDERAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.637,  Lanes on structure: 10,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.1m (134.8ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 36.6m (120.1ft),  Out-to-Out Width: 42.7m (140.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Discuss Denver, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.