Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Houston, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 4,433Number of bridges
  • 145,748ft / 44,424mTotal length
  • $113,750,000Total costs
  • 148,292,432Total average daily traffic
  • 8,915,561Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Houston
  • No street view available for this location

New bridges in Houston, TX - historical statistics
  • New bridges - historical statistics
  • 31910-1919
  • 91920-1929
  • 131930-1939
  • 371940-1949
  • 1401950-1959
  • 5831960-1969
  • 5371970-1979
  • 7781980-1989
  • 9001990-1999
  • 7342000-2009
  • 6482010-2019
  • 512020-2022
Reconstructed bridges in Houston, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21940-1949
  • 41950-1959
  • 111960-1969
  • 391970-1979
  • 991980-1989
  • 1111990-1999
  • 742000-2009
  • 642010-2019
  • 62020-2022
Average Bridge Daily Traffic in Houston, TX
Average Bridge Truck Traffic in Houston, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 0.1%Excellent
  • 6.2%Very good
  • 57.4%Good
  • 32.5%Satisfactory
  • 3.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.6%Excellent
  • 49.3%Very good
  • 24.0%Good
  • 2.8%Satisfactory
  • 0.3%Fair
  • 0.2%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 8.1%Very good
  • 61.7%Good
  • 26.6%Satisfactory
  • 2.9%Fair
  • 0.6%Poor
  • 0.1%Critical
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.6%Very good
  • 56.0%Good
  • 29.9%Satisfactory
  • 5.0%Fair
  • 0.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 69.0%Very good
  • 29.3%Good
  • 1.7%Satisfactory
  • 0.7%Fair
  • 0.2%Poor
Find on map >>   Show street view

Structure Number: 121020TOL030003,  Location: 0.50 MI W OF IH 610 (Lat: 29.725925,  Lng: -95.465006),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 9,000 (year 2013),  Truck Traffic: 2%,  Features Intersected: S Rice Ave,  Facility Carried by Structure: WESTPARK TLWY EB
Minimum Vertical Clearance: 7.11m (23.33ft),  Lanes on structure: 2,  Lanes under structure: 11,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.5m (123.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030004,  Location: 0.42 MI W OF IH 610 (Lat: 29.725503,  Lng: -95.466111),  Route carried "under" structure: Other road ,  Year Built: 2004,  Structure Length: 0. m,  Features Intersected: UPTOWN TRANSIT CENTER,  Facility Carried by Structure: WESTPARK TLWY RAMP
Minimum Vertical Clearance: 3.05m (10.01ft),  Kilometerpoint: 20.258,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030005,  Location: 0.87 MI W OF IH 610 (Lat: 29.725239,  Lng: -95.473442),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 5,120 (year 2013),  Features Intersected: Chimney Rock & Royalton,  Facility Carried by Structure: WESTPARK TLWY EB
Minimum Vertical Clearance: 5.64m (18.50ft),  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030007,  Location: 0.94 MI W OF IH 610 (Lat: 29.725317,  Lng: -95.473486),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 5,120 (year 2013),  Features Intersected: Westpark & Chimney Rock,  Facility Carried by Structure: WESTPARK TLWY RAMP
Minimum Vertical Clearance: 6.65m (21.82ft),  Lanes on structure: 1,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030008,  Location: 0.50 MI E OF HILLCROFT (Lat: 29.722739,  Lng: -95.499372),  Route carried "under" structure: US 59,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 26,100 (year 2010),  Truck Traffic: 10%,  Features Intersected: US59 & Wpark Toll Conn 6,  Facility Carried by Structure: WSTPRK TLWY CONN 4
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 20,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 102.1m (335.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030009,  Location: 0.55 MI E OF HILLCROFT (Lat: 29.723519,  Lng: -95.493411),  Route carried "under" structure: ServiceState highway ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 5,120 (year 2013),  Truck Traffic: 1%,  Features Intersected: US 59 SBFR & Westpark Dr,  Facility Carried by Structure: WSTPRK TLWY CONN 5
Minimum Vertical Clearance: 8.56m (28.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 74.7m (245.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL03001,  Location: 0.30 MI W OF US 59 (Lat: 29.723036,  Lng: -95.499731),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Hillcroft Ave & 14th St,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 1.609,  Lanes on structure: 3,  Lanes under structure: 11,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 121020TOL030013,  Location: 2.25 MI E OF BELTWAY 8 (Lat: 29.721133,  Lng: -95.520078),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Fondren Rd,  Facility Carried by Structure: WESTPARK TLWY EB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 1.770,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.5m (123.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030014,  Location: 2.55 MI E OF BELTWAY 8 (Lat: 29.721758,  Lng: -95.514875),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Fondren Rd & Westpark Dr,  Facility Carried by Structure: WESTPARK TLWY WB
Minimum Vertical Clearance: 5.97m (19.59ft),  Kilometerpoint: 1.770,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.5m (123.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030015,  Location: 2.60 MI E OF BELTWAY 8 (Lat: 29.721994,  Lng: -95.513142),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Dunvale Rd/W Park Dr EB,  Facility Carried by Structure: TOLLWAY WB OFF-RP
Minimum Vertical Clearance: 6.65m (21.82ft),  Kilometerpoint: 11.104,  Lanes on structure: 1,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030016,  Location: 1.05 MI E OF BELTWAY 8 (Lat: 29.719456,  Lng: -95.542531),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 20,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Gessner Rd,  Facility Carried by Structure: WESTPARK TLWY EB
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 11.748,  Lanes on structure: 2,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030017,  Location: 1.18 MI E OF BELTWAY 8 (Lat: 29.719725,  Lng: -95.540658),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 20,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Gessner Rd,  Facility Carried by Structure: WESTPARK TLWY WB
Minimum Vertical Clearance: 5.01m (16.44ft),  Kilometerpoint: 11.829,  Lanes on structure: 2,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030018,  Location: 0.50 MI E OF BELTWAY 8 (Lat: 29.718969,  Lng: -95.548881),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Briarpark / Ranchester,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.161,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 12.2m (40.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030019,  Location: 0.70 MI E OF WILCREST DR (Lat: 29.718219,  Lng: -95.559650),  Route carried "under" structure: Other road 8,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 80,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: BW 8 & Rogerdale Rd,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 16.093,  Lanes on structure: 4,  Lanes under structure: 22,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 121020TOL03002,  Location: 0.10 MI W OF BELTWAY 8 (Lat: 29.717900,  Lng: -95.559447),  Route carried "under" structure: Other road ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Westpark Toll EB Ramp E,  Facility Carried by Structure: ROGERDALE RD
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.016,  Lanes on structure: 4,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 15.9m (52.2ft)

Find on map >>   Show street view

Structure Number: 121020TOL030021,  Location: 0.35 MI W OF RANCHESTER (Lat: 29.718903,  Lng: -95.555064),  Route carried "under" structure: Other road ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: Wpark TW WB Off-RP I,  Facility Carried by Structure: W.PK WB ON-RP DC-2
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.837,  Lanes on structure: 1,  Lanes under structure: 1,  Toll: Toll bridge is a segment,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030022,  Location: 0.05 MI N OF WESTPK TLWY (Lat: 29.719681,  Lng: -95.557411),  Route carried "under" structure: Other road ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: BW 8 SB Conn Rp DC-1,  Facility Carried by Structure: BW 8 NBML
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 16.093,  Lanes on structure: 4,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030023,  Location: 0.05 MI N OF WESTPK TLWY (Lat: 29.718881,  Lng: -95.557050),  Route carried "under" structure: Other road ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: BW 8 SB Conn Rp DC-1,  Facility Carried by Structure: BW 8 NB CONN DC-2
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 16.093,  Lanes on structure: 1,  Lanes under structure: 1,  Toll: Toll bridge is a segment,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030024,  Location: 0.40 MI W OF RANCHESTER (Lat: 29.718122,  Lng: -95.557942),  Route carried "under" structure: Other road ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 50,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: BW 8 ML & NB Conn DC-2,  Facility Carried by Structure: WESTPK. TW EB CONN
Minimum Vertical Clearance: 6.35m (20.83ft),  Kilometerpoint: 16.093,  Lanes on structure: 2,  Lanes under structure: 10,  Toll: Toll bridge is a segment,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030025,  Location: 0.40 MI W OF RANCHESTER (Lat: 29.719156,  Lng: -95.557711),  Route carried "under" structure: Other road ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 50,000 (year 2013),  Truck Traffic: 5%,  Features Intersected: BW 8 ML & NB Conn DC-2,  Facility Carried by Structure: WESTPK. WB RP I-K
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 16.093,  Lanes on structure: 2,  Lanes under structure: 10,  Toll: Toll bridge is a segment,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 121020TOL030027,  Location: 0.85 MI W OF BELTWAY 8 (Lat: 29.717183,  Lng: -95.571094),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 20,000 (year 2013),  Truck Traffic: 1%,  Features Intersected: Wilcrest Dr,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 2.253,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 121020TOL030029,  Location: 2.10 MI W OF BELTWAY 8 (Lat: 29.715611,  Lng: -95.591422),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 1%,  Features Intersected: West Houston Center Blvd,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 2.575,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL03003,  Location: 2.85 MI W OF BELTWAY 8 (Lat: 29.714372,  Lng: -95.605222),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 23,860 (year 2015),  Features Intersected: Dairy Ashford Rd,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 2.575,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030031,  Location: 1.75 M E OF SH 6 (Lat: 29.713100,  Lng: -95.614739),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 10,028 (year 2013),  Truck Traffic: 1%,  Features Intersected: Synott Rd,  Facility Carried by Structure: WESTPRK TLWY RP EB
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 2.736,  Lanes on structure: 1,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 82.6m (271.0ft)

Find on map >>   Show street view

Structure Number: 121020TOL030032,  Location: 1.75 MI E OF SH 6 (Lat: 29.713519,  Lng: -95.614711),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 8,780 (year 2013),  Truck Traffic: 1%,  Features Intersected: Synott Rd,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 2.736,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030033,  Location: 1.20 MI E OF SH 6 (Lat: 29.712914,  Lng: -95.623567),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 4,000 (year 2013),  Features Intersected: Eldridge Parkway,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 2.575,  Lanes on structure: 5,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030037,  Location: 1.35 MI W OF IH 610 (Lat: 29.724203,  Lng: -95.480808),  Route carried "under" structure: City street ,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2011),  Features Intersected: Renwick Dr & Alder Dr,  Facility Carried by Structure: WESTPARK TOLLWAY
Minimum Vertical Clearance: 5.77m (18.93ft),  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL030038,  Location: 0.10 MI NE OF WESTWARD (Lat: 29.723703,  Lng: -95.488142),  Route carried "under" structure: ServiceState highway 59,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 5,120 (year 2013),  Truck Traffic: 1%,  Features Intersected: US 59 NBFR & Rampart St,  Facility Carried by Structure: WSTPRK TLWY CONN 6
Minimum Vertical Clearance: 7.26m (23.82ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 121020TOL04021,  Location: 0.2 MI S OF FM 1960 (Lat: 30.022572,  Lng: -95.404622),  Route carried "under" structure: City street ,  Year Built: 1988,  Structure Length: 0. m,  Average Daily Traffic: 1,800 (year 2010),  Truck Traffic: 5%,  Features Intersected: BAMMEL-WESTFIELD RD,  Facility Carried by Structure: HARDY TOLL RD
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 92.223,  Lanes on structure: 8,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.8m (78.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL040212,  Location: 4.4 MI N OF BWY 8 (Lat: 29.996239,  Lng: -95.396875),  Route carried "under" structure: City street ,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 8,110 (year 2015),  Features Intersected: E RICHEY RD,  Facility Carried by Structure: HARDY TOLL RD
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 28.968,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.9m (52.2ft)

Find on map >>   Show street view

Structure Number: 121020TOL040213,  Location: 0.85 MI S OF E RICHEY RD (Lat: 29.984653,  Lng: -95.393986),  Route carried "under" structure: City street ,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2014),  Truck Traffic: 15%,  Features Intersected: AIRTEX DRIVE,  Facility Carried by Structure: HARDY TOLL RD
Minimum Vertical Clearance: 5.69m (18.67ft),  Kilometerpoint: 96.207,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 121020TOL040214,  Location: 0.6 MI N OF RANKIN RD (Lat: 29.974150,  Lng: -95.390661),  Route carried "under" structure: City street ,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2015),  Truck Traffic: 15%,  Features Intersected: UPRR & E HARDY RD,  Facility Carried by Structure: HARDY TOLL RD
Minimum Vertical Clearance: 8.21m (26.94ft),  Kilometerpoint: 97.478,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL040215,  Location: 1.9 MI N OF BELTWAY 8 (Lat: 29.965342,  Lng: -95.379858),  Route carried "under" structure: City street ,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2013),  Truck Traffic: 15%,  Features Intersected: Rankin Road,  Facility Carried by Structure: HARDY TOLL RD
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 98.814,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 121020TOL040218,  Location: 0.9 MI N OF BW 8 (Lat: 29.951314,  Lng: -95.384256),  Route carried "under" structure: County highway ,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 2,630 (year 2015),  Features Intersected: Old Greens Rd,  Facility Carried by Structure: HARDY TOLL RD
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 100.880,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 121700011004122,  Location: 0.2 MI N OF HARRIS C/L (Lat: 30.113708,  Lng: -95.438258),  Route carried "under" structure: Ramp Other road ,  Year Built: 1990,  Structure Length: 0. m,  Features Intersected: IH 45 SBFR,  Facility Carried by Structure: IH 45 SBFR
Minimum Vertical Clearance: 4.80m (15.75ft),  Lanes on structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 121700011004123,  Location: 0.2 MI N OF HARRIS C/L (Lat: 30.113708,  Lng: -95.438258),  Route carried "under" structure: Ramp Other road ,  Year Built: 1990,  Structure Length: 0. m,  Features Intersected: IH 45 SBML,  Facility Carried by Structure: IH 45 SBML
Minimum Vertical Clearance: 4.80m (15.75ft),  Lanes on structure: 5,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 121700011004124,  Location: 0.2 MI N OF HARRIS C/L (Lat: 30.113708,  Lng: -95.438258),  Route carried "under" structure: Ramp Other road ,  Year Built: 1990,  Structure Length: 0. m,  Features Intersected: IH 45 NBML,  Facility Carried by Structure: IH 45 NBML
Minimum Vertical Clearance: 4.80m (15.75ft),  Lanes on structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 121700011004125,  Location: 0.2 MI N OF HARRIS C/L (Lat: 30.113708,  Lng: -95.438258),  Route carried "under" structure: Ramp Other road ,  Year Built: 1990,  Structure Length: 0. m,  Features Intersected: IH 45 NBFR,  Facility Carried by Structure: IH 45 NBFR
Minimum Vertical Clearance: 4.80m (15.75ft),  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 121700011004132,  Location: 1.2 MI N OF HARRIS C/L (Lat: 30.126914,  Lng: -95.442872),  Route carried "under" structure: City street ,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 211 (year 2014),  Features Intersected: IH 45 NB,  Facility Carried by Structure: IH 45 NB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.161,  Lanes on structure: 11,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 121700011004133,  Location: 1.2 MI N OF HARRIS C/L (Lat: 30.126817,  Lng: -95.443528),  Route carried "under" structure: City street ,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 211 (year 2014),  Features Intersected: IH 45 SB,  Facility Carried by Structure: IH 45 SB
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.161,  Lanes on structure: 11,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 121700011004199,  Location: 3.55 MI S OF SH 242 (Lat: 30.155006,  Lng: -95.449511),  Route carried "under" structure: ServiceInterstate 45,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 19,160 (year 2012),  Truck Traffic: 6%,  Features Intersected: WOODLANDS PKWY CONN
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 4.973,  Lanes on structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 121700017705264,  Location: 3.75 MI S OF FM 1485 (Lat: 30.104472,  Lng: -95.236275),  Route carried "under" structure: State highway 1314,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2016),  Truck Traffic: 7%,  Features Intersected: US 59 ML,  Facility Carried by Structure: US 59 ML
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 33.577,  Lanes on structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 121700017705527,  Location: 2.45 MI S OF FM 1314 (Lat: 30.069700,  Lng: -95.246667),  Route carried "under" structure: County highway ,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 4,000 (year 2016),  Truck Traffic: 5%,  Features Intersected: US 59,  Facility Carried by Structure: US 59
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 0.805,  Lanes on structure: 8,  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>   Show street view

Structure Number: 121700017705528,  Location: 0.90 MI S OF HARRIS C/L (Lat: 30.052619,  Lng: -95.251675),  Route carried "under" structure: County highway ,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2016),  Truck Traffic: 5%,  Features Intersected: US 59,  Facility Carried by Structure: US 59
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.805,  Lanes on structure: 8,  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>   Show street view

Structure Number: 121700017705552,  Location: AT JCT IH 69 AND SH 99 (Lat: 30.122394,  Lng: -95.230828),  Route carried "under" structure: ServiceState highway 99,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2016),  Truck Traffic: 2%,  Features Intersected: IH 69, WHITE OAK CREEK
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 88.665,  Lanes on structure: 1,  Lanes under structure: 23,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.2m (131.9ft)

Find on map >>   Show street view

Structure Number: 121700351007186,  Location: 2.1 MI NE OF HRDY TOLL RD (Lat: 30.110358,  Lng: -95.387933),  Route carried "under" structure: County highway ,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 1,500 (year 2016),  Features Intersected: RAYFORD RD,  Facility Carried by Structure: SH 99 EB
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 121700351007187,  Location: 2.5 MI NE OF HRDYTOLL RD (Lat: 30.115483,  Lng: -95.382078),  Route carried "under" structure: County highway ,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2016),  Features Intersected: BIRNHAM WOODS DRIVE,  Facility Carried by Structure: SH 99 EB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Find on map >>   Show street view

Structure Number: 121700351007189,  Location: 2.1 MI NE OF HRDY TOLL RD (Lat: 30.110997,  Lng: -95.387636),  Route carried "under" structure: County highway ,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 1,500 (year 2016),  Truck Traffic: 2%,  Features Intersected: RAYFORD RD,  Facility Carried by Structure: SH 99 WB
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 12170035100719,  Location: 2.5 MI NE OF HRDYTOLL RD (Lat: 30.115994,  Lng: -95.381731),  Route carried "under" structure: County highway ,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2016),  Truck Traffic: 1%,  Features Intersected: BIRNHAM WOODS DRIVE,  Facility Carried by Structure: SH 99 WB
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.7m (127.0ft)

Discuss Houston, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.